1 February 2019 in International Journal of Thermal Sciences
5 February 2016 in Journal of Building Physics
In the first part of this series, we discussed that the building structure, energy efficiency, indoor environmental quality, and moisture management all need to be considered simultaneously to ensure durability of materials and control cost of near-zero energy buildings. These factors must be addressed through contributions of the whole design team. It is also evident that building physics must take an active role in development of near-zero energy buildings. The need to ensure good indoor environment and durability of materials and limit the cost of buildings led to integrated design process that now is typical in Canada for design of low-energy buildings. Furthermore, interactions between energy efficiency, quality of indoor environment and moisture management led us to introduce a concept of “environmental control.” In the meantime, we made an unexpected observation—Vancouver dwellings in 2002 use the same amount of energy as 1920 uninsulated masonry buildings erected in the same location. We concluded that despite having advanced technology, our lack of vision prevents us from an effective use of this technology. With the quest for sustainable buildings, we should learn more from termites, who appear to master the art of hygrothermal control better than humans as they are capable of maintaining highly stable interior comfort zone without heating, ventilating, and air-conditioning equipment. Nevertheless, whatever progress is achieved in new low-energy buildings, it is lost when rehabilitating existing buildings because there an owner will typically do one step at a time. If the financial constraints do not allow for more, this first step should be an integrated action that includes a combination of insulation and heating systems.
20 August 2019 in Science and Technology for the Built Environment
The article concerns the wind washing of the cavity insulation in leaky walls. The measurements in lightweight timber frame buildings have shown large amounts of air filtration that affect heat transfer through the envelope. This article presents the results of a laboratory study on wind washing of structures that are insulated with loose mineral wool, with partial and without wind protection (corresponding to meet existing ones), under different wind loads. Wind washing led to an 85% reduction of thermal resistance in the examined structures. Long-term measurements also show problems of subsidence of loose fibrous material in the construction, which leads to increased convection heat transfer.
1 December 2016 in Energy and Buildings
1 December 2016 in Applied Mechanics and Materials
The paper presents the problem of windwashing in partitions including air permeable thermal insulations. There are technical solutions, which deliberately accept the filtration of air in the insulating layer, guided by the necessity of possible drying of building materials. Some scientific papers even suggest that the air infiltration decrease the heat losses through ventilation. In result there occur heat losses in building heat balance which are underestimated and therefore difficult to take into account during calculations. Heat changes on the inner surface of the building partition occur with a delay to the initiation of the wind. However, even the short-term local wind speed loads on thermal insulations result in temperature decreasing and therefore possible condensation on the inner surface of the building partition. The article presents laboratory measurements of air permeability of loose mineral wool and laboratory investigation of the impact of air filtration on heat transfer in lightweight partitions filled with loose thermal insulation.
1 October 2017 in Energy Procedia