Xuanhe Fan

Xuanhe Fan

Auto-generated profile, based on publicly available information

Xuanhe Fan

Huazhong University of Science and Technology

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in Physiological Measurement
Verified
Journal Article
Closed access
XFXuanhe Fan
Xuanhe Fan
FLFangwu Liu
Fangwu Liu
JZJinjin Zhang
Jinjin Zhang
TGTong Gao
Tong Gao
ZFZiyang Fan
Ziyang Fan
JZJingjing Zhang
Jingjing Zhang
Objective . In previous studies, the factors affecting the accuracy of imaging photoplethysmography (iPPG) heart rate (HR) measurement have been focused on the light intensity, facial reflection angle, and motion artifacts. However, the factor of specularly reflected light has not been studied in detail. We explored the effect of specularly reflected light on the accuracy of HR estimation and proposed an estimation method for the direction of specularly radiated light. Approach . To study the HR measurement accuracy influenced by specularly reflected light, we control the component of specularly reflected light by controlling its angle. A total of 100 videos from four different reflected light angles were collected, and 25 subjects participated in the dataset collection. We extracted angles and illuminations for 71 facial regions, fitting sample points through interpolation, and selecting the angle corresponding to the maximum weight in the fitted curve as the estimated reflected angle. Main results . The experimental results show that higher specularly reflected light compromises HR estimation accuracy under the same value of light intensity. Notably, at a 60° angle, the HR accuracy (ACC) increased by 0.7%, while the signal-to-noise ratio and Pearson correlation coefficient increased by 0.8 dB and 0.035, respectively, compared to 0°. The overall root mean squared error, standard deviation, and mean error of our proposed reflected light angle estimation method on the illumination multi-angle incidence (IMAI) dataset are 1.173°, 0.978°, and 0.773°. The average Pearson value is 0.8 in the PURE rotation dataset. In addition, the average ACC of HR measurements in the PURE dataset is improved by 1.73% in our method compared to the state-of-the-art traditional methods. Significance . Our method has great potential for clinical applications, especially in bright light environments such as during surgery, to improve accuracy and monitor blood volume changes in blood vessels.

13 October 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XFXuanhe Fan
Xuanhe Fan
FLFangwu Liu
Fangwu Liu
ZHZhijie Huang
Zhijie Huang
WXWei Xue
Wei Xue
TGTong Gao
Tong Gao
JZJingjing Zhang
Jingjing Zhang
Region of interest (ROI) selection is a key process for remote heart rate measurement approach. Previous studies have shown that the selected ROI could easily be lost under head rotation circumstances and does not perform well under drastic changes in illumination. To solve the problems, this work proposed a novel adaptive ROI selection method. Firstly, we collected a dataset for modeling the signal-to-noise ratio (SNR) evaluated by illumination and reflection angle. Secondly, we established an SNR estimated model by studying the mathematical correlations between light intensity, reflected angle, and SNR of the regions on the face. Then, we proposed a robust ROI selection method based on SNR estimated model for adaptive ROI selection. Finally, the ROI change de-noising method is proposed to remove the ROI change noise for synthesizing the imaging Photoplethysmography (iPPG) signal and calculating the heart rate. Performances of the proposed method were tested on three datasets, including our collected dataset and two public datasets. The experimental results show that on the MR-NIRP CAR dataset, the percentage of the time that the heart rate (HR) error is less than 6 bpm (PET6) value is higher than 7.3% and 4.6%, respectively, compared with the State-of-the-art (SOTA) methods. The SNR, standard deviation error (SD), mean absolute error (MAE), and root mean squared error (RMSE) metrics are also improved on the Head-rotation and PURE datasets. Therefore, our method is robust and can potentially be applied in various scenarios.

29 October 2025 in Expert Systems with Applications
Verified
Journal Article
Closed access
SHShuangjiang He
Shuangjiang He
HZHuijuan Zhao
Huijuan Zhao
XFXuanhe Fan
Xuanhe Fan
ZLZhenyu Li
Zhenyu Li
LLLinyun Liu
Linyun Liu
YLYu Li
Yu Li

1 January 2026 in IEEE Transactions on Circuits and Systems for Video Technology
Verified
Journal Article
Closed access
HZHuijuan Zhao
Huijuan Zhao
SHShuangjiang He
Shuangjiang He
XFXuanhe Fan
Xuanhe Fan
YLYulin Li
Yulin Li
ZCZhenhua Cai
Zhenhua Cai
LYLi Yu
Li Yu

1 September 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XFXuanhe Fan
Xuanhe Fan
LLLi Li
Li Li
HZHuijuan Zhao
Huijuan Zhao
SHShuangjiang He
Shuangjiang He
ZXZiheng Xu
Ziheng Xu
LYLi Yu
Li Yu