Brandon J. Nelson

Brandon J. Nelson

Auto-generated profile, based on publicly available information

Brandon J. Nelson

Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Labs, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
ESElisabeth R. Shanblatt
Elisabeth R. Shanblatt
YSYongjin Sung
Yongjin Sung
RGRajiv Gupta
Rajiv Gupta
BNBrandon J. Nelson
Brandon J. Nelson
SLShuai Leng
Shuai Leng
CMCynthia H. McCollough
Cynthia H. McCollough
We demonstrate a fast, flexible, and accurate paraxial wave propagation model to serve as a forward model for propagation-based X-ray phase contrast imaging (XPCI) in parallel-beam or cone-beam geometry. This model incorporates geometric cone-beam effects into the multi-slice beam propagation method. It enables rapid prototyping and is well suited to serve as a forward model for propagation-based X-ray phase contrast tomographic reconstructions. Furthermore, it is capable of modeling arbitrary objects, including those that are strongly or multi-scattering. Simulation studies were conducted to compare our model to other forward models in the X-ray regime, such as the Mie and full-wave Rytov solutions.

1 July 2023 in Journal of the American College of Radiology
Verified
Journal Article
Closed access
BNBrandon J. Nelson
Brandon J. Nelson
RZRongping Zeng
Rongping Zeng
MSMarla B.K. Sammer
Marla B.K. Sammer
DFDonald P. Frush
Donald P. Frush
JDJana G. Delfino
Jana G. Delfino

4 April 2022
Verified
Conference Paper
Open access
BNBrandon J. Nelson
Brandon J. Nelson
SLShuai Leng
Shuai Leng
TKThomas Koenig
Thomas Koenig
CMCynthia H. McCollough
Cynthia H. McCollough
SPIE Digital Library Proceedings

23 November 2017 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
YSYongjin Sung
Yongjin Sung
RGRajiv Gupta
Rajiv Gupta
BNBrandon Nelson
Brandon Nelson
SLShuai Leng
Shuai Leng
CMCynthia H. McCollough
Cynthia H. McCollough
WGWilliam S. Graves
William S. Graves
X-ray phase-contrast imaging (XPCI) overcomes the problem of low contrast between different soft tissues achieved in conventional x-ray imaging by introducing x-ray phase as an additional contrast mechanism. This work describes a compact x-ray light source (CXLS) and compares, via simulations, the high quality XPCI results that can be produced from this source to those produced using a microfocus x-ray source. The simulation framework is first validated using an image acquired with a microfocus-source, propagation-based XPCI (PB-XPCI) system. The phase contrast for a water sphere simulating a simple cyst submersed in muscle is evaluated and the evolution of PB-XPCI signal as the object to detector distance is increased is demonstrated. The proposed design of a PB-XPCI system using the CXLS is described and simulated images of a coronary artery compared between CXLS and microfocus source PB-XPCI systems. To generate images with similar noise levels, a microfocus source would require a 3000 times longer exposure than would the CXLS. We conclude that CXLS technology has the potential to provide high-quality XPCI in a medical environment using extremely short exposure times relative to microfocus source approaches.