Felix Schrank

Felix Schrank

Auto-generated profile, based on publicly available information

Felix Schrank

Department of Radiology, Charité - Universitätsmedizin Berlin, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2019 in Soft Matter
Verified
Journal Article
Open access
PDF file
FSFrank Sauer
Frank Sauer
LOLinda Oswald
Linda Oswald
ASAngela Ariza de Schellenberger
Angela Ariza de Schellenberger
HTHeiko Tzschätzsch
Heiko Tzschätzsch
FSFelix Schrank
Felix Schrank
JKJosef Alfons Käs
Josef Alfons Käs
Collagen accounts for the major extracellular matrix (ECM) component in many tissues and provides mechanical support for cells. Magnetic Resonance (MR) Imaging, MR based diffusion measurements and MR Elastography (MRE) are considered sensitive to the microstructure of tissues including collagen networks of the ECM. However, little is known whether water diffusion interacts with viscoelastic properties of tissues. This study combines highfield MR based diffusion measurements, novel compact tabletop MRE and confocal microscopy in collagen networks of different cross-linking states (untreated collagen gels versus additional treatment with glutaraldehyde). The consistency of bulk rheology and MRE within a wide dynamic range is demonstrated in heparin gels, a viscoelastic standard for MRE. Additional crosslinking of collagen led to an 8-fold increased storage modulus, a 4-fold increased loss modulus and a significantly decreased power law exponent, describing multi-relaxational behavior, corresponding to a pronounced transition from viscous-soft to elastic-rigid properties. Collagen network changes were not detectable by MR based diffusion measurements and microscopy which are sensitive to the micrometer scale. The MRE-measured shear modulus is sensitive to collagen fiber interactions which take place on the intrafiber level such as fiber stiffness. The insensitivity of MR based diffusion measurements to collagen hydrogels of different cross-linking states alludes that congeneric collagen structures in connective tissues do not hinder extracellular diffusive water transport. Furthermore, the glutaraldehyde induced rigorous changes in viscoelastic properties indicate that intrafibrillar dissipation is the dominant mode of viscous dissipation in collagen-dominated connective tissue.

6 March 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
JMJoaquin Mura
Joaquin Mura
FSFelix Schrank
Felix Schrank
ISIngolf Sack
Ingolf Sack
Purpose: Magnetic resonance elastography (MRE) measures stiffness of soft tissues by analyzing their spatial harmonic response to externally induced shear vibrations. Many MRE methods use inversion‐based reconstruction approaches, which invoke first‐ or second‐order derivatives by finite difference operators (first‐ and second‐FDOs) and thus give rise to a biased frequency dispersion of stiffness estimates.Methods: We here demonstrate analytically, numerically, and experimentally that FDO‐based stiffness estimates are affected by (1) noise‐related underestimation of values in the range of high spatial wave support, that is, at lower vibration frequencies, and (2) overestimation of values due to wave discretization at low spatial support, that is, at higher vibration frequencies.Results: Our results further demonstrate that second‐FDOs are more susceptible to noise than first‐FDOs and that FDO dispersion depends both on signal‐to‐noise ratio (SNR) and on a lumped parameter A, which is defined as wavelength over pixel size and over a number of pixels per stencil of the FDO. Analytical FDO dispersion functions are derived for optimizing A parameters at a given SNR. As a simple rule of thumb, we show that FDO artifacts are minimized when A/2 is in the range of the square root of 2SNR for the first‐FDO or cubic root of 5SNR for the second‐FDO.Conclusions: Taken together, the results of our study provide an analytical solution to a long‐standing, well‐recognized, yet unsolved problem in MRE postprocessing and might thus contribute to the ongoing quest for minimizing inversion artifacts in MRE.

28 November 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
FSFelix Schrank
Felix Schrank
CWCarsten Warmuth
Carsten Warmuth
SGSteffen Görner
Steffen Görner
TMTom Meyer
Tom Meyer
HTHeiko Tzschätzsch
Heiko Tzschätzsch
ISIngolf Sack
Ingolf Sack
Purpose To develop and test real‐time MR elastography for viscoelastic parameter quantification in skeletal muscle during dynamic exercises. Methods In 15 healthy participants, 6 groups of lower‐leg muscles (tibialis anterior, tibialis posterior, peroneus, extensor digitorum longus, soleus, gastrocnemius) were investigated by real‐time MR elastography using a single‐shot, steady‐state spiral gradient‐echo pulse sequence and stroboscopic undersampling of harmonic vibrations at 40 Hz frequency. One hundred and eighty consecutive maps of shear‐wave speed and loss angle (φ) covering 30.6 s of total acquisition time at 5.9‐Hz frame rate were reconstructed from 360 wave images encoding 2 in‐plane wave components in an interleaved manner. The experiment was carried out twice to investigate 2 exercises—isometric plantar flexion and isometric dorsiflexion—each performed over 10 s between 2 resting periods. Results Activation of lower‐extremity muscles was associated with increasing viscoelastic parameters shear‐wave speed and φ, both reflecting properties related to the transverse direction relative to fiber orientation. Major viscoelastic changes were observed in soleus muscle during plantar flexion (shear‐wave speed: 20.0% ± 3.6%, φ: 41.3% ± 12.0%) and in the tibialis anterior muscle during dorsiflexion (41.8% ± 10.2%, φ: 27.9% ± 2.8%; all P < .0001). Two of the muscles analyzed were significantly activated by plantar flexion and 4 by dorsiflexion based on shear‐wave speed, whereas φ changed significantly in 5 muscles during both exercises. Conclusion Real‐time MR elastography allows mapping of dynamic, nonperiodic viscoelasticity changes in soft tissues such as voluntary muscle with high spatial and temporal resolution. Real‐time MR elastography thus opens new horizons for the in vivo study of physiological processes in soft tissues toward functional elastography.