Kai Zhang

Kai Zhang

Auto-generated profile, based on publicly available information

Kai Zhang

Key Laboratory of Environment Optics and Technology of Chinese Academy of Sciences, Anhui Institute of Optics and Fine Mechanics, CAS, Hefei, Anhui, 230031,China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2011 in Journal of Water Supply: Research and Technology—AQUA
Verified
Journal Article
Open access
PDF file
KZKai Zhang
Kai Zhang
JSJie Shen
Jie Shen
GYGao-Fang Yin
Gao-Fang Yin
ZWZhigang Wang
Zhigang Wang
CSChaoyi Shi
Chaoyi Shi
WLWen-Qing Liu
Wen-Qing Liu

1 January 2017 in Journal of Spectroscopy
Verified
Journal Article
Open access
PDF file
KZKai Zhang
Kai Zhang
YZYujun Zhang
Yujun Zhang
KYKun You
Kun You
YHYing He
Ying He
QGQiankun Gao
Qiankun Gao
WLWenqing Liu
Wenqing Liu
It becomes a key technology to measure the concentration of the vehicle exhaust components with the transmission spectra. But in the conventional methods for noise reduction and baseline correction, such as wavelet transform, derivative, interpolation, polynomial fitting, and so forth, the basic functions of these algorithms, the number of decomposition layers, and the way to reconstruct the signal have to be adjusted according to the characteristics of different components in the transmission spectra. The parameter settings of the algorithms above are not transcendental, so with them, it is difficult to achieve the best noise reduction effect for the vehicle exhaust spectra which are sharp and drastic in the waveform. In this paper, an adaptive ensemble empirical mode decomposition (EEMD) denoising model based on a special normalized index optimization is proposed and used in the spectral noise reduction of vehicle exhaust NOX. It is shown with the experimental results that the method can effectively improve the accuracy of the spectral noise reduction and simplify the denoising process and its operation difficulty.

1 May 2020 in Optik
Verified
Journal Article
Closed access
KZKai Zhang
Kai Zhang
SHSiyu Huang
Siyu Huang
HLHoubing Lu
Houbing Lu
FLFei Li
Fei Li
LSLi Shao
Li Shao

16 August 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
BFBoqiang Fan
Boqiang Fan
YZYujun Zhang
Yujun Zhang
KZKai Zhang
Kai Zhang
QTQixing Tang
Qixing Tang
DYDongqi Yu
Dongqi Yu
When using infrared gas detection technology to measure gas concentration, due to the immobilization of parameters such as cell, detector and light source, the range of the detection gas concentration is limited. In order to achieve the wide range of infrared gas detection system, an automatic program-controlled gain circuit system is designed based on MCP42010. Through the MCU to determine whether the current photoelectric signal is saturated, the resistance of the programmable potentiometer is automatically changed to achieve wide dynamic range detection. The simulation results show that the auto-programmed gain module's amplified photoelectric signal is within the effective resolution range of the A/D converter and meets the actual requirements of infrared gas detection.

16 August 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
GLGuohua Liu
Guohua Liu
YZYujun Zhang
Yujun Zhang
KZKai Zhang
Kai Zhang
In order to ensure that the vehicle exhaust analyzer can work normally with the harsh conditions of the high temperature exhaust, the sample gas must be dewatered, dedusted and cooled without distortion. A new pretreatment technology for motor vehicle exhaust has been proposed in this paper. On the basis of the principle of cyclone separator with particles filter chamber, cyclone separator, liquid resistance and membrane type dryer as main devices, the particles filter chamber for dedusting, metal spiral pipe for cooling, cyclone separator for dewatering and dedusting, liquid resistance and membrane type dryer for dewatering have been used in the designed system. It can pretreat the exhaust without changing the exhaust composition, so the sample gas clarity can be increased. Field experiment results show that the designed pretreatment system can remove more than 5 um particle diameter. With it the exhaust temperature of range (180,210)°C can drop to around 39°C, the relative exhaust humidity of range (65,75)% can fall to about 25%, which can ensure the long-term stable operation of the online analysis instrument for high temperature exhaust.