4 June 2025 in Advanced Science
As one of the most advanced in vitro drug screening platforms, tumor organoids require accurate pharmacosensitivity assessments to ensure reliable results. However, achieving accurate volume assessment of these 3D organoid models remains a challenge in traditional drug screening processes. Here, a label‐free organoids photoacoustic imaging (LFOPI) system is introduced for high‐resolution 3D imaging of tumor organoids. The capabilities of the LFOPI system are evaluated by monitoring structural transformations in melanoma organoids. The LFOPI system is further employed for volumetric drug screening of melanoma tumor organoids. Drug screening with cisplatin and temozolomide reveal that LFOPI‐based organoid volume data correlates more strongly with viability trends (0.8627 and 0.9069) than traditional diameter‐based methods (0.8190 and 0.7849). Additionally, immunotherapy drug screening demonstrates the capability of the system to precisely assess the 3D volumes of irregularly shaped organoids. This LFOPI system provides a promising method for label‐free drug screening and personalized treatment.
8 November 2017 in Applied Optics
While photoacoustic computed tomography (PACT) is generally built with planar transducers of finite size, most current reconstruction algorithms assume the transducer to be an ideal point, which leads to a spinning blur in the consequently obtained PACT images due to the model mismatch. In this work, we put forward an improved back-projection method that factors in the geometry of the transducers to improve the tangential resolution for the reconstruction of 2D circular-scanning-based photoacoustic tomography. Extensive simulations and experiments were carried out to study the adaptability and stability of the proposed method. Results show that this method can effectively restore the tangential distortion of the PACT image for both simulated and experimental data. Results indicated that the improvement of the tangential resolution is more obvious for transducers with larger size. We also demonstrated the application of this method to transducers other than planar, and results show that the reconstructed image quality can be significantly affected by the shape and position of the transducers used. This study may help to guide the selection of transducer and design of scanning strategy in PACT.
20 December 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
In vivo imaging of skin is commonly used to investigate dynamic processes in the progression and treatment of psoriasis. Photoacoustic mesoscopy is a new non-invasive imaging modality widely used in bio-imaging, and has recently been applied to imaging skin in vivo . However, photoacoustic imaging has shortcomings. Although high-frequency ultrasonic transducers enable high-resolution photoacoustic imaging, the images may be bandwidth-limited. To overcome this limitation, we designed and fabricated a broadband ultrasonic transducer for photoacoustic mesoscopy. The center frequency of the transducer was 32 MHz (88% bandwidth at −6 dB). The transducer was used to visualize mouse and human skin morphology. Colocalization of high- and low-frequency components revealed information about both the skin surface and dermis. To explore dynamic structural changes in mouse back skin during psoriasis progression, we measured blood oxygen saturation and total hemoglobin in a mouse model using multiwavelength imaging without contrast agents. The results indicate that functional photoacoustic mesoscopy using a broadband high-frequency transducer has great potential for clinical imaging of skin disease.
12 December 2025 in IEEE Transactions on Medical Imaging
Optical-resolution photoacoustic microscopy (OR-PAM) can visualize cellular-level wavelength-dependent optical absorption with high resolution and sensitivity. However, the imaging speed of OR-PAM has been limited by the laser repetition rate due to the point-by-point scanning of a focused laser beam. To overcome this limitation, we propose multifocal optical-resolution photoacoustic microscopy (MOR-PAM) with a single-element ultrasonic transducer, leveraging the diffractive optical element (DOE) and a custom-designed encoding acoustic mask. The DOE generates 8 focal spots of 3 μm diameter. The acoustic mask was designed to encode photoacoustic signals from different focal spots. MOR-PAM achieved an 8-fold increase in imaging speed compared to conventional OR-PAM with the same laser repetition rate. We demonstrated the MOR-PAM using a 266 nm laser at 10 KHz, providing solutions for rapid OR-PAM beyond the laser repetition rate in a cost-effective way. The proposed method can be applied to versatile OR-PAM configurations and enable new applications where high-speed imaging is critical.
30 June 2026 in Optics & Laser Technology
17 August 2026 in Ultrasonics