Itaru Oda

Itaru Oda

Auto-generated profile, based on publicly available information

Itaru Oda

Department of Orthopaedic Surgery, Hokkaido University Graduate School of Medicine, Sapporo, Japan

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 1999 in Spine
Verified
Journal Article
Closed access
IOItaru Oda
Itaru Oda
KAKuniyoshi Abumi
Kuniyoshi Abumi
LSLaura C. Sell
Laura C. Sell
CHCharles J. Haggerty
Charles J. Haggerty
BCBryan W. Cunningham
Bryan W. Cunningham
PMPaul C. McAfee
Paul C. McAfee
The stabilizing effects of five different occipitocervical fixations were compared. To evaluate the construct stability provided by five different occipito-atlanto-axial fixation techniques. Few studies have addressed occipitocervical reconstruction stability and no studies to date have investigated anterior-posterior translational stiffness. A total of 21 human cadaveric spines were used. After testing intact spines (CO-C2), a type II dens fracture was created and five different reconstructions were performed: 1) occipital and sublaminar wiring/rectangular rod, 2) occipital screws and C2 lamina claw hooks/rod, 3) occipital screws, foramen magnum screws, and C1-C2 transarticular screws/rod, 4) occipital screws and C1-C2 transarticular screws/Y-plate, and 5) occipital screws and C2 pedicle screws/rod. Biomechanical testing parameters included axial rotation, flexion/extension, lateral bending, and anterior-posterior translation. Pedicle screw fixation demonstrated the highest stiffness among the five reconstructions (P< 0.05). The two types of transarticular screw methods provided greater stability than hook or wiring reconstructions (P< 0.05). The C2 claw hook technique resulted in greater stability than sublaminar wiring fixation in anterior-posterior translation (P< 0.05). However, the wiring procedure did not significantly increase the stiffness levels beyond the intact condition under anterior-posterior translation and lateral bending (P> 0.05). C2 transpedicular and C1-C2 transarticular screws significantly increased the stabilizing effect compared to sublaminar wiring and lamina hooks. The improved stability afforded by C2 pedicular and C1-C2 transarticular screws offer many potential advantages including a high rate of bony union, early ambulation, and easy nursing care. Occipitocervical reconstruction techniques using C1-C2 transarticular screws or C2 pedicle screws offer biomechanical advantages compared to sublaminar wiring or lamina hooks. Pedicle screw fixation exhibited the highest construct stiffness among the fivereconstructions.

1 October 1999 in Spine
Verified
Journal Article
Closed access
IOItaru Oda
Itaru Oda
BCBryan W. Cunningham
Bryan W. Cunningham
RBRudolph A. Buckley
Rudolph A. Buckley
MGMichael J. Goebel
Michael J. Goebel
CHCharles J. Haggerty
Charles J. Haggerty
PMPaul C. McAfee
Paul C. McAfee
In an in vivo sheep model, the effects of spinal fusion and kyphotic deformity on the neighboring motion segments were analyzed. To investigate the effects of spinal fusion and kyphotic deformity on the adjacent motion segment. The in vivo effects of kyphotic deformity on the neighboring motion segments have not been investigated in any studies. Eighteen sheep were equally randomized into three groups based on surgical procedure: L3–L5 in situ posterolateral fusion (n = 6) L3–L5 kyphotic posterolateral fusion (n = 6), and surgical exposure alone (n = 6). After a 16-week survival period, the adjacent motion segment changes were analyzed radiographically, biomechanically, and histologically. The kyphosis group showed 5.0° ± 2.6° and 1.7° ± 1.8° compensatory hyperlordosis at L2–L3 and L5–L6, respectively. compared with surgical exposure and in situ posterolateral fusion, the kyphotic posterolateral fusion significantly influenced cranial adjacent motion segment biomechanics by inducing more stiffness in the posterior ligamentous complex (P< 0.05) and increasing lamina strain under flexion–extension loading (P< 0.05). Results of histologic analysis showed significant degenerative changes of the L2–L3 facet joints in the kyphosis group. It is inferred that in the kyphosis group, compensatory hyperlordosis at the cranial adjacent level leads to lordotic contracture of the posterior ligamentous complex. The increased lamina strain, exhibited by the in situ group under flexion–extension, was further increased in the kyphosis group, indicating higher load transmission through the posterior column. Significant degenerative changes of the cephalad adjacent facet joints observed in the kyphosis group served to corroborate the biomechanical data. These results indicate that a kyphotic deformity may lead to facet joint contracture and facet arthritis and may serve as the origin of low back pain at the cranial adjacent level.

1 February 2002 in Spine
Verified
Journal Article
Closed access
IOItaru Oda
Itaru Oda
KAKuniyoshi Abumi
Kuniyoshi Abumi
BCBryan W. Cunningham
Bryan W. Cunningham
KKKiyoshi Kaneda
Kiyoshi Kaneda
PMPaul C. McAfee
Paul C. McAfee
An in vitro human cadaveric study comparing the effects of anterior and posterior sequential destabilization conditions on thoracic functional unit mechanics was studied. To investigate the biomechanical properties of the human thoracic spine. Few studies have addressed the mechanical role of the costovertebral joints under torsion in the stability of the human thoracic spine. Sixteen functional spinal units with intact costovertebral joints were obtained from six human cadavers and randomized into two groups based on destabilization procedures: Group 1, anterior to posterior sequential resection; and Group 2, posterior to anterior sequential destabilization. Biomechanical testing was performed after each destabilization procedure, and the range of motion under maximum load was calculated. Group 1: Under flexion–extension, lateral bending, and axial rotation loading, discectomy increased the range of motion by 193%, 74%, and 111%, respectively. Moreover, subsequent right rib head resection further increased the range of motion by 81%, 84%, and 72%, respectively. Group 2: Under all loading conditions laminectomy + medial facetectomy resulted in a 22–30% increase in range of motion. Subsequent total facetectomy led to an additional 15–28% increase in range of motion. The rib head joints serve as stabilizing structures to the human thoracic spine in the sagittal, coronal, and transverse planes. In anterior scoliosis surgery additional rib head resection after discectomy may achieve greater curve and rib hump correction. The lateral portion of the facet joints plays an important role in providing spinal stability and should be preserved to minimize postoperative kyphotic deformity and segmental instability when performing decompressive wide laminectomy.

1 June 2006 in Spine
Verified
Journal Article
Closed access
IOItaru Oda
Itaru Oda
KAKuniyoshi Abumi
Kuniyoshi Abumi
MIManabu Ito
Manabu Ito
YKYoshihisa Kotani
Yoshihisa Kotani
TOTakashi Oya
Takashi Oya
AMAkio Minami
Akio Minami
Study Design. A retrospective study. Objectives. To evaluate clinical outcomes of palliative spinal reconstruction using cervical pedicle screws in metastatic spine tumors. Summary of Background Data. No study to date has investigated the effectiveness of cervical pedicle screw fixation in metastatic lesions of the spine. Methods. A total of 32 patients with metastatic spine tumors who underwent reconstructive surgery using cervical pedicle screws were reviewed. Four patients presented upper cervical lesions and 28 patients had subaxial lesions. All patients had intractable pain, 29 presented myelopathy, and 18 patients were nonambulatory. Combined anterior column reconstruction was considered in cases of life expectancy more than 2 years and anterior spinal cord compression that could not be solved by posterior decompression and kyphosis correction. Posterior fixation alone was performed in 25 patients, and posterior fixation combined with anterior column reconstruction was performed in 7 patients. Results. The average postoperative survival period was 12.2 months. Neck pain was improved in all cases. Twenty-four (83%) of the 29 patients with spinal cord lesions presented neurologic improvement. Of 18 patients who were not ambulatory, 16 patients (89%) became ambulatory. Pain relief, neurologic function, and spinal stability were maintained throughout the survival period in 30 of 32 patients (94%). Conclusion. Spinal reconstruction using cervical pedicle screws improved spinal stability, pain, and neurologic function. These improvements were maintained throughout the survival period in 94% of the patients. Anterior column reconstruction could be avoided in 78% of the patients in spite of damaged anterior column.

1 September 2000 in Spine
Verified
Journal Article
Closed access
IOItaru Oda
Itaru Oda
BCBryan W. Cunningham
Bryan W. Cunningham
GLGuy A. Lee
Guy A. Lee
KAKuniyoshi Abumi
Kuniyoshi Abumi
KKKiyoshi Kaneda
Kiyoshi Kaneda
PMPaul C. McAfee
Paul C. McAfee
Three types of anterior thoracolumbar multisegmental fixation were biomechanically compared in construct stiffness and rod–screw strain. To investigate the effects of rod diameter and rod number on construct stiffness and rod–screw strain in anterior thoracolumbar multisegmental instrumentation. No studies have been undertaken to investigate the biomechanical effects of rod diameter and rod number in thoracolumbar anterior instrumentation. Ten fresh-frozen calf spines (T13–L5) were used. After intact analysis, a total discectomy and transection of the ALL and PLL were performed at L1–L2, L2–L3, and L3–L4 with intervertebral reconstruction using carbon fiber cages. Three types of anterior fixation were then performed at L1–L4: 1) 4.75-mm diameter single-rod, 2) 4.75-mm dual-rod, and 3) 6.35-mm single-rod systems. Single screws at each vertebra were used for single-rod and two screws for dual-rod fixation. These systems share the same basic design except rod diameter. Nondestructive biomechanical testing was performed and included compression, torsion, flexion–extension, and lateral bending. Construct stiffness and rod–screw strain of the three reconstructions were compared. The 6.35-mm single-rod fixation significantly improved construct stiffness compared with the 4.75-mm single rod fixation only under torsion (P < 0.05). The 4.75-mm dual rod construct resulted in significantly higher stiffness than did both single-rod fixations (P < 0.05), except under compression. No statistical differences were observed in rod–screw strain between the two types of single rods, whereas dual-rod reconstruction exhibited less rod–screw strain (P < 0.05). For single-rod fixation, increased rod diameter neither markedly improved construct stiffness nor affected rod–screw strain, indicating the limitations of a single-rod system. In thoracolumbar anterior multisegmental instrumentation, the dual-rod fixation provides higher construct stiffness and less rod–screw strain compared with single-rod fixation.

1 March 2022 in Journal of Orthopaedic Science
Verified
Journal Article
Closed access
RFRyo Fujita
Ryo Fujita
IOItaru Oda
Itaru Oda
HTHirohito Takeuchi
Hirohito Takeuchi
SOShigeki Oshima
Shigeki Oshima
MFMasanori Fujiya
Masanori Fujiya
YKYoshiharu Kawaguchi
Yoshiharu Kawaguchi