Ulrich Rassner

Ulrich Rassner

Auto-generated profile, based on publicly available information

Ulrich Rassner

From the Department of Radiology (J.A.C., U.A.R.), University of Utah Hospital, Salt Lake City, Utah

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Radiology
Verified
Journal Article
Closed access
MHMichael N. Hoff
Michael N. Hoff
AMAlexander McKinney
Alexander McKinney
FSFrank G. Shellock
Frank G. Shellock
URUlrich Rassner
Ulrich Rassner
TGTobias Gilk
Tobias Gilk
EKEmanuel Kanal
Emanuel Kanal
Although 7-T MRI has recently received approval for use in clinical patient care, there are distinct safety issues associated with this relatively high magnetic field. Forces on metallic implants and radiofrequency power deposition and heating are safety considerations at 7 T. Patient bioeffects such as vertigo, dizziness, false feelings of motion, nausea, nystagmus, magnetophosphenes, and electrogustatory effects are more common and potentially more pronounced at 7 T than at lower field strengths. Herein the authors review safety issues associated with 7-T MRI. The rationale for safety concerns at this field strength are discussed as well as potential approaches to mitigate risk to patients and health care professionals.

31 March 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JCJustin Cramer
Justin Cramer
URU.A. Rassner
U.A. Rassner
GHG.L. Hedlund
G.L. Hedlund
SUMMARY: A possible misconception among radiologists is that chronic subdural hemorrhage should show some degree of blooming on T2*–gradient recalled-echo or susceptibility-weighted sequences such as SWI and susceptibility-weighted angiography, which is not necessarily true. We present 5 cases of chronic subdural hemorrhages in infants, demonstrating intensity near or greater than that of CSF with variable amounts of hemosiderin staining along the neomembranes. We review the physiology and MR imaging physics behind the appearance of a chronic subdural hemorrhage, highlighting that the absence of a BBB can allow hemosiderin to be completely removed from the subdural compartment. Finally, we stress the importance of reviewing all multiplanar sequences for the presence of neomembranes, which can be quite subtle in the absence of hemosiderin staining and are critical for making the diagnosis of chronic subdural hemorrhage.