Jacqueline Dinnes

Jacqueline Dinnes

Auto-generated profile, based on publicly available information

Jacqueline Dinnes

Department of Applied Health Sciences, College of Medicine and Health, University of Birmingham, Birmingham, UK

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2003 in Health Technology Assessment
Verified
Journal Article
Closed access
PDF file
JDJ Deeks
J Deeks
JDJ Dinnes
J Dinnes
RDRoberto D‘Amico
Roberto D‘Amico
ASA Sowden
A Sowden
CSC Sakarovitch
C Sakarovitch
DAD Altman
D Altman
Health Technology Assessment Volume: 7, Issue: 27, Published in September 2003

25 June 2020 in Cochrane Database of Systematic Reviews
Verified
Journal Article
Open access
PDF file
JDJonathan J Deeks
Jonathan J Deeks
JDJacqueline Dinnes
Jacqueline Dinnes
YTYemisi Takwoingi
Yemisi Takwoingi
CDClare Davenport
Clare Davenport
RSRené Spijker
René Spijker
CGCochrane COVID-19 Diagnostic Test Accuracy Group
Cochrane COVID-19 Diagnostic Test Accuracy Group
Background The severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) virus and resulting COVID‐19 pandemic present important diagnostic challenges. Several diagnostic strategies are available to identify current infection, rule out infection, identify people in need of care escalation, or to test for past infection and immune response. Serology tests to detect the presence of antibodies to SARS‐CoV‐2 aim to identify previous SARS‐CoV‐2 infection, and may help to confirm the presence of current infection. Objectives To assess the diagnostic accuracy of antibody tests to determine if a person presenting in the community or in primary or secondary care has SARS‐CoV‐2 infection, or has previously had SARS‐CoV‐2 infection, and the accuracy of antibody tests for use in seroprevalence surveys. Search methods We undertook electronic searches in the Cochrane COVID‐19 Study Register and the COVID‐19 Living Evidence Database from the University of Bern, which is updated daily with published articles from PubMed and Embase and with preprints from medRxiv and bioRxiv. In addition, we checked repositories of COVID‐19 publications. We did not apply any language restrictions. We conducted searches for this review iteration up to 27 April 2020. Selection criteria We included test accuracy studies of any design that evaluated antibody tests (including enzyme‐linked immunosorbent assays, chemiluminescence immunoassays, and lateral flow assays) in people suspected of current or previous SARS‐CoV‐2 infection, or where tests were used to screen for infection. We also included studies of people either known to have, or not to have SARS‐CoV‐2 infection. We included all reference standards to define the presence or absence of SARS‐CoV‐2 (including reverse transcription polymerase chain reaction tests (RT‐PCR) and clinical diagnostic criteria). Data collection and analysis We assessed possible bias and applicability of the studies using the QUADAS‐2 tool. We extracted 2x2 contingency table data and present sensitivity and specificity for each antibody (or combination of antibodies) using paired forest plots. We pooled data using random‐effects logistic regression where appropriate, stratifying by time since post‐symptom onset. We tabulated available data by test manufacturer. We have presented uncertainty in estimates of sensitivity and specificity using 95% confidence intervals (CIs). Main results We included 57 publications reporting on a total of 54 study cohorts with 15,976 samples, of which 8526 were from cases of SARS‐CoV‐2 infection. Studies were conducted in Asia (n = 38), Europe (n = 15), and the USA and China (n = 1). We identified data from 25 commercial tests and numerous in‐house assays, a small fraction of the 279 antibody assays listed by the Foundation for Innovative Diagnostics. More than half (n = 28) of the studies included were only available as preprints. We had concerns about risk of bias and applicability. Common issues were use of multi‐group designs (n = 29), inclusion of only COVID‐19 cases (n = 19), lack of blinding of the index test (n = 49) and reference standard (n = 29), differential verification (n = 22), and the lack of clarity about participant numbers, characteristics and study exclusions (n = 47). Most studies (n = 44) only included people hospitalised due to suspected or confirmed COVID‐19 infection. There were no studies exclusively in asymptomatic participants. Two‐thirds of the studies (n = 33) defined COVID‐19 cases based on RT‐PCR results alone, ignoring the potential for false‐negative RT‐PCR results. We observed evidence of selective publication of study findings through omission of the identity of tests (n = 5). We observed substantial heterogeneity in sensitivities of IgA, IgM and IgG antibodies, or combinations thereof, for results aggregated across different time periods post‐symptom onset (range 0% to 100% for all target antibodies). We thus based the main results of the review on the 38 studies that stratified results by time since symptom onset. The numbers of individuals contributing data within each study each week are small and are usually not based on tracking the same groups of patients over time. Pooled results for IgG, IgM, IgA, total antibodies and IgG/IgM all showed low sensitivity during the first week since onset of symptoms (all less than 30.1%), rising in the second week and reaching their highest values in the third week. The combination of IgG/IgM had a sensitivity of 30.1% (95% CI 21.4 to 40.7) for 1 to 7 days, 72.2% (95% CI 63.5 to 79.5) for 8 to 14 days, 91.4% (95% CI 87.0 to 94.4) for 15 to 21 days. Estimates of accuracy beyond three weeks are based on smaller sample sizes and fewer studies. For 21 to 35 days, pooled sensitivities for IgG/IgM were 96.0% (95% CI 90.6 to 98.3). There are insufficient studies to estimate sensitivity of tests beyond 35 days post‐symptom onset. Summary specificities (provided in 35 studies) exceeded 98% for all target antibodies with confidence intervals no more than 2 percentage points wide. False‐positive results were more common where COVID‐19 had been suspected and ruled out, but numbers were small and the difference was within the range expected by chance. Assuming a prevalence of 50%, a value considered possible in healthcare workers who have suffered respiratory symptoms, we would anticipate that 43 (28 to 65) would be missed and 7 (3 to 14) would be falsely positive in 1000 people undergoing IgG/IgM testing at days 15 to 21 post‐symptom onset. At a prevalence of 20%, a likely value in surveys in high‐risk settings, 17 (11 to 26) would be missed per 1000 people tested and 10 (5 to 22) would be falsely positive. At a lower prevalence of 5%, a likely...

1 January 2007 in Health Technology Assessment
Verified
Journal Article
Open access
PDF file
JDJ Dinnes
J Dinnes
JDJ Deeks
J Deeks
HKH Kunst
H Kunst
AGA Gibson
A Gibson
ECE Cummins
E Cummins
ALA Lalvani
A Lalvani
Health Technology Assessment Volume: 11, Issue: 3, Published in January 2007

1 February 2002 in International Journal of Epidemiology
Verified
Journal Article
Open access
PDF file
FSFujian Song
Fujian Song
Khalid KhanKhalid Khan
Khalid Khan
JDJacqueline Dinnes
Jacqueline Dinnes
ASAlex J Sutton
Alex J Sutton
Background Despite the great possibility of publication bias in studies of diagnostic test research, empirical studies about publication bias have mainly focused on studies of treatment effect. Methods A sample of 28 meta-analyses of diagnostic accuracy was selected from the Database of Abstracts of Reviews of Effectiveness (DARE). Methods used to deal with publication and related biases in these meta-analyses were examined. Asymmetry of funnel plot of estimated test accuracy against corresponding precision for each meta-analysis was assessed by three statistical methods: rank correlation method, regression analysis, and Trim and Fill method. Results In reviews of diagnostic accuracy, there was a general lack of consideration of appropriate literature searching to minimize publication bias, and the impact of possible publication bias has not been systematically assessed. The results of the three different statistical methods consistently showed that in a large proportion of the 28 meta-analyses evaluated, the smaller studies were associated with a greater diagnostic accuracy. Exploratory analyses found that the fewer the literature databases searched, the greater the funnel plot asymmetry in meta-analyses. Funnel plot asymmetry tended to be greater in meta-analyses that included smaller number of primary studies. Our data revealed no consistent relationship between funnel plot asymmetry and language restriction in reviews. Conclusions Further research is required to explain why smaller studies tended to report greater test accuracy in a large proportion of meta-analyses of diagnostic tests. In systematic reviews of diagnostic studies, literature search should be sufficiently comprehensive and possible impact of publication bias should be assessed.

1 March 2005 in Health Technology Assessment
Verified
Journal Article
Open access
PDF file
JDJ Dinnes
J Dinnes
JDJ Deeks
J Deeks
JKJ Kirby
J Kirby
PRP Roderick
P Roderick
Health Technology Assessment Volume: 9, Issue: 12, Published in March 2005

1 June 2004 in Health Technology Assessment
Verified
Journal Article
Open access
PDF file
PWPenny Whiting
Penny Whiting
ARA Rutjes
A Rutjes
JDJ Dinnes
J Dinnes
JRJ Reitsma
J Reitsma
PBP Bossuyt
P Bossuyt
JKJ Kleijnen
J Kleijnen
Health Technology Assessment Volume: 8, Issue: 25, Published in June 2004