Sahand Pirouzpanah

Sahand Pirouzpanah

Auto-generated profile, based on publicly available information

Sahand Pirouzpanah

Texas A&M University, College Station, TX

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Journal of Petroleum Science and Engineering
Verified
Journal Article
Closed access
SPSahand Pirouzpanah
Sahand Pirouzpanah
SGSujan R. Gudigopuram
Sujan R. Gudigopuram
GMGerald L. Morrison
Gerald L. Morrison

1 December 2014 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
SPSahand Pirouzpanah
Sahand Pirouzpanah
MÇMuhammet Çevik
Muhammet Çevik
GMGerald L. Morrison
Gerald L. Morrison

1 August 2016 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
GAGautham Annamalai
Gautham Annamalai
SPSahand Pirouzpanah
Sahand Pirouzpanah
SGSujan R. Gudigopuram
Sujan R. Gudigopuram
GMGerald L. Morrison
Gerald L. Morrison

7 July 2013
Verified
Conference Paper
Closed access
PDF file
EMEmanuel Marsis
Emanuel Marsis
SPSahand Pirouzpanah
Sahand Pirouzpanah
GMGerald Morrison
Gerald Morrison
Computational fluid dynamics (CFD) is widely used to simulate fluid flows in turbomachinery. A detailed CFD study was performed to enhance the design of an electrical submersible pump (ESP) manufactured by Baker Hughes. The pump has a special patented impeller design enabling it to handle up to 70% gas volume fraction (GVF). A CFD-based design study was performed on the ESP diffuser (for the first time) to improve the pump’s performance and reduce losses. The CFD model was initially validated using experimental results. Different designs were simulated to reach the optimum design. Many factors affect pump performance, including flow separation losses in the stator (such as the number of blades, the meridional profile of the pump and the shape of the stator blades). In addition, a non-uniform flow while exiting one stage affects the rotor performance of the next stage. Therefore, improving the diffuser design improves the current stage performance as well as the performance of the next rotor. In this study, improved designs show that optimizing the stator design can increase the static pressure of the pump by 4% for single-phase flow, and 23% for two-phase flow in the simulated cases.

1 December 2014 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
SPSahand Pirouzpanah
Sahand Pirouzpanah
BEBurak Erdoğan
Burak Erdoğan
GMGerald L. Morrison
Gerald L. Morrison

7 July 2013
Verified
Conference Paper
Closed access
PDF file
GMGerald Morrison
Gerald Morrison
SPSahand Pirouzpanah
Sahand Pirouzpanah
MCMuhammet Cevik
Muhammet Cevik
APAbhay Patil
Abhay Patil
The feasibility of a multiphase flow meter utilizing closely coupled slotted orifice and swirl flow meters along with an impedance sensor is investigated. The slotted flow meter has been shown to exhibit well behaved response curves to two phase flow mixtures with the pressure difference monotonically increasing with mixture density and flow rate. It has been determined to have less than 1% uncertainty in determining the flow rate if the density of the fluid is known. Flow visualizations have shown that the slotted orifice is a very good mixing device as well producing a homogenous mixture for several pipe diameters downstream of the plate. This characteristic is utilized to provide a homogeneous mixture at the inlet to the swirl meter. This is possible since the slotted orifice is relatively insensitive to upstream and downstream flow disturbances. The swirl meter has been shown to indicate decreased flow rate as the mixture density increases which is opposite to the slotted orifice making the solution of the two meter outputs to obtain density and flow rate feasible. Additional instrumentation is included. Between the slotted orifice and swirl meter where the flow is homogenous a custom manufactured electrical impedance sensor is installed and monitored. This array of instrumentation will provide three independent measurements which are evaluated to determine which system of equations are robust enough to provide accurate density and flow rate measurement over a wide range of gas volume fractions using a very compact system.