Ilan Mor

Ilan Mor

Auto-generated profile, based on publicly available information

Ilan Mor

Soreq NRC, Yavne 81800, Israel

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
RZRobert Zboray
Robert Zboray
VDVolker Dangendorf
Volker Dangendorf
IMIlan Mor
Ilan Mor
BBBenjamin Bromberger
Benjamin Bromberger
KTKai Tittelmeier
Kai Tittelmeier
In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

1 October 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
IMIlan Mor
Ilan Mor
NENissan Eldad
Nissan Eldad
MCMoshe Cohen
Moshe Cohen
RHReuven Hacham-Zada
Reuven Hacham-Zada

1 May 2023 in Journal of Instrumentation
Verified
Journal Article
Open access
ARA. Roy
A. Roy
DVD. Vartsky
D. Vartsky
IMI. Mor
I. Mor
CBC. Boiano
C. Boiano
SBS. Brambilla
S. Brambilla
LAL. Arazi
L. Arazi
In this contribution we report on further investigations of the recently-evaluated Constant-Fraction Time-over-Threshold (CF-ToT) method for neutron/gamma-ray Pulse Shape Discrimination (PSD). The superiority of the CF-ToT PSD method over the constant-threshold (CT-ToT) method was previously demonstrated, down to low neutron energy thresholds of 100 keVee. Here, we report on a quantitative comparison between the traditionally used Charge Comparison (CC) method and the CF-ToT method using a stilbene scintillator coupled to a silicon photomultiplier, implementing an offline analysis of recorded fast-neutron and gamma-ray waveforms. An optimization of the constant fraction value indicates that a 20%-fraction yields the optimum figure-of-merit (FOM) and gamma-ray peak-to-valley (P/V) ratio. The results obtained for a particle energy threshold of 100 keVee (kilo electron Volt electron equivalent) show that the FOM and P/V values achieved with the CF-ToT method are superior to those obtained using the standard CC method. In addition, a first electronic implementation of the CF-ToT method was performed using simple circuitry suitable for multichannel architecture. Initial results obtained with this circuit prototype are presented.

1 February 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YYY. Yehuda-Zada
Y. Yehuda-Zada
DVD. Vartsky
D. Vartsky
GMG. Martínez-Lema
G. Martínez-Lema
IMI. Mor
I. Mor
ECE. Cohen
E. Cohen
LAL. Arazi
L. Arazi