Luke G. Johnson

Luke G. Johnson

Auto-generated profile, based on publicly available information

Luke G. Johnson

School of Biomedical Engineering, University of British Columbia, Vancouver, Canada

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2023 in JBI Evidence Synthesis
Verified
Journal Article
Open access
LJLuke G. Johnson
Luke G. Johnson
SBSara Bortolussi-Courval
Sara Bortolussi-Courval
ACAnjuli Chehil
Anjuli Chehil
ESEmily K. Schaeffer
Emily K. Schaeffer
CPColleen Pawliuk
Colleen Pawliuk
KMKishore Mulpuri
Kishore Mulpuri
Objective: The objective of this scoping review was to identify all examples of the application of statistical shape models to the human hip joint, with a focus on applications, population, methodology, and validation. Introduction: Clinical radiographs are the most common imaging tool for management of hip conditions, but it is unclear whether radiographs can adequately diagnose or predict outcomes of 3D deformity. Statistical shape modeling, a method of describing the variation of a population of shapes using a small number of variables, has been identified as a useful tool to associate 2D images with 3D anatomy. This could allow clinicians and researchers to validate clinical radiographic measures of hip deformity, develop new ones, or predict 3D morphology directly from radiographs. In identifying all previous examples of statistical shape modeling applied to the human hip joint, this review determined the prevalence, strengths, and weaknesses, and identified gaps in the literature. Inclusion criteria: Participants included any human population. The concept included development or application of statistical shape models based on discrete landmarks and principal component analysis. The context included sources that exclusively modeled the hip joint. Only peer-reviewed original research journal articles were eligible for inclusion. Methods: We searched MEDLINE, Embase, Cochrane CENTRAL, IEEE Xplore, Web of Science Core Collection, OCLC PapersFirst, OCLC Proceedings, Networked Digital Library of Theses and Dissertations, ProQuest Dissertations and Theses Global, and Google Scholar for sources published in English between 1992 and 2021. Two reviewers screened sources against the inclusion criteria independently and in duplicate. Data were extracted by 2 reviewers using a REDCap form designed to answer the review study questions, and are presented in narrative, tabular, and graphical form. Results: A total of 104 sources were considered eligible based on the inclusion criteria. From these, 122 unique statistical shape models of the human hip were identified based on 86 unique training populations. Models were most often applied as one-off research tools to describe shape in certain populations or to predict outcomes. The demographics of training populations were skewed toward older patients in high-income countries. A mean age between 60 and 79 years was reported in 29 training populations (34%), more than reported in all other age groups combined, and 73 training populations (85%) were reported or inferred to be from Europe and the Americas. Only 4 studies created models in a pediatric population, although 15 articles considered shape variation over time in some way. There were approximately equal numbers of 2D and 3D models. A variety of methods for labeling the training set was observed. Most articles presented some form of validation such as reporting a model’s compactness (n = 71), but in-depth validation was rare. Conclusions: Despite the high volume of literature concerning statistical shape models of the human hip, there remains a need for further research in key areas. We identified the lack of models in pediatric populations and low- and middle-income countries as a notable limitation to be addressed in future research.

13 November 2020 in JBI Evidence Synthesis
Verified
Journal Article
Closed access
LJLuke G. Johnson
Luke G. Johnson
CPColleen Pawliuk
Colleen Pawliuk
Objective: This review aims to identify all examples of the application of statistical shape models to the human hip joint, with a focus on methodology, validation, and applications. Introduction: Abnormal hip joint morphology (eg, deformity secondary to Legg-Calvé-Perthes disease) is an important precursor to osteoarthritis. Clinical radiographs are often used to characterize deformity and provide indication for surgical correction, but it is unclear whether radiographs can adequately describe three-dimensional deformity. Statistical shape modeling, a method of describing a population of shapes using a small number of variables, has been identified as a potential tool that will allow clinicians and researchers to validate current and novel radiographic measurements of hip deformity. In identifying all previous examples of statistical shape modeling applied to the hip joint, this review will determine its prevalence, strengths, and weaknesses, and identify gaps in the literature. Inclusion criteria: Peer-reviewed and gray literature focusing on the development and/or application of statistical shape models to the human hip joint will be included. Methods: Several relevant databases, including Ovid MEDLINE, Embase, and IEEE, will be searched for literature published from 1992, and for a title and abstract that can be searched in English. After removal of duplicates, two reviewers will independently screen papers by title and abstract, then screen the full text of selected or uncertain papers. The same reviewers will then independently chart data from the final selection. At each stage, disagreements will be resolved through discussion or third-party arbitration.

1 December 2025 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
LJLuke G. Johnson
Luke G. Johnson
DWDavid R. Wilson
David R. Wilson
KMKishore Mulpuri
Kishore Mulpuri
Purpose: The dynamic stress environment in the hip joint is thought to contribute to pain and osteoarthritis (OA) in people with Legg–Calvé–Perthes disease (LCPD) deformity, but is poorly understood, limiting clinical management options. The objective of this study was to develop and evaluate a patient-specific biomechanical “digital twin” model of LCPD to predict chondrolabral shear stress in dynamic and static loading scenarios. Methods: We produced a digital twin model of both hips in a patient with unilateral LCPD deformity using anatomical magnetic resonance imaging (MRI) and the ArtiSynth modeling platform. We evaluated the model’s sensitivity to changes in material properties and joint angles during a typical gait cycle, and verified its stress and femoral translation predictions against upright open MRI of the hip in high-flexion postures. Results: The model’s prediction of the highest chondrolabral shear stress during a gait cycle was 22–93% greater in the LCPD hip than in the unaffected hip. The model was sensitive to changes in material parameters and joint angles, but could accurately reproduce femoral translation and expected stress distribution in extreme static postures. Conclusion: This study demonstrates the importance of both dynamic motion and morphology in the stress environment of highly aspherical hip joints. Although some challenges remain, digital twin models are a promising tool to study the long-term outcomes of LCPD, and could be applied in future to aid clinical management.

27 February 2025 in Osteoarthritis and Cartilage Open
Verified
Journal Article
Open access
LJLuke G. Johnson
Luke G. Johnson
CJCarly E. Jones
Carly E. Jones
DRDaniel G. Rosenbaum
Daniel G. Rosenbaum
BJBenjamin Joseph
Benjamin Joseph
ESEmily K. Schaeffer
Emily K. Schaeffer
DWDavid R. Wilson
David R. Wilson
To determine whether the relationship between cartilage T1ρ relaxation time and age during adolescence and young adulthood is different in hips with Legg–Calvé–Perthes disease (LCPD) deformity compared to hips without LCPD deformity. We recruited 17 participants with LCPD deformity and 15 control participants aged 10–25 years in this frequency-matched cohort study. Quantitative magnetic resonance images were obtained for both hips in LCPD participants and one hip from each control using a T1ρ MAPSS sequence. The average T1ρ relaxation time in the weight-bearing articular cartilage was calculated, and we tested the interacting effects of age and participant group (LCPD vs non-LCPD) or subgroup (control, contralateral LCPD, spherical LCPD, and aspherical LCPD) on T1ρ using mixed effects models. The main effect of age on T1ρ relaxation time in hips without LCPD deformity was −0.63 ​ms/year (95 ​% confidence interval [−0.94, −0.32]). The age-adjusted main effect of LCPD deformity was +2.93 ​ms [0.65, 3.42] and the interaction effect of age and LCPD deformity was +0.46 ​ms/year [0.16, 0.76]. Moderate differences were observed between control and contralateral LCPD subgroups, and between spherical LCPD and aspherical LCPD subgroups. Age-related changes in T1ρ relaxation time differ between hips with and without LCPD deformity, suggesting that cartilage degradation in LCPD is progressive and begins early in the healed stage of LCPD. By young adulthood, the difference in T1ρ between LCPD and non-LCPD hips is clinically important when considering osteoarthritis progression and outcomes.

10 March 2025 in Journal of Pediatric Orthopaedics
Verified
Journal Article
Open access
LJLuke G. M.Eng. Johnson
Luke G. M.Eng. Johnson
HZHonglin Zhang
Honglin Zhang
BJBenjamin Mbbs Joseph
Benjamin Mbbs Joseph
ESEmily K. Schaeffer
Emily K. Schaeffer
KMKishore Mbbs Mulpuri
Kishore Mbbs Mulpuri
DWDavid R. D.Phil. Wilson
David R. D.Phil. Wilson
Background: The mechanical environment in the hip in people with residual Legg-Calvé-Perthes disease (LCPD) deformity is still poorly understood. Anterior impingement is thought to contribute to poor long-term outcomes such as early-onset osteoarthritis, but it has not been measured directly using imaging in high flexion. Our objective in this study was to determine the association between radiographic morphologic scores of LCPD deformity and reduced anterior hip clearance. Methods: We measured the anterior clearance (β-angle) of 20 LCPD-affected hips (17 patients) scanned in 4 functional postures using an upright open MRI scanner. Mixed effects models were used to describe the relationship between β, posture, and morphologic measures of deformity (Stulberg classification and Sphericity Deviation Score). Results: Hip β-angle was significantly associated with posture (P<0.001). Aspherical (Stulberg III to V) hips had lower β across all postures compared with spherical (Stulberg I to II) hips (difference in β = −39.1 degrees; 95% CI: −71.9 to −6.2 degrees; P=0.020). An increased SDS was strongly associated with reduced β in neutral hip postures (P=0.002, 0.005, respectively), but not with elevated adduction and internal rotation. Due to morphologic heterogeneity, 6 hips (out of 20 overall) did not fit the overall trend. Conclusions: Our results show an association between more severe radiographic deformity and a greater potential for anterior impingement, a known contributor to cartilage degradation. However, the large proportion of cases where morphologic deformity does not align with functional clearance suggests current radiographic measures of deformity may not be sufficient to predict long-term outcomes in every LCPD patient. Clinical Relevance: (1) Hip joint asphericity in LCPD is associated with less anterior clearance and a greater potential for anterior impingement in high flexion postures. (2) Considering both morphologic and functional parameters may improve our understanding of the causes of pain and early-onset osteoarthritisin LCPD, as opposed to morphology alone.

22 October 2025 in Orthopaedic Proceedings
Verified
Journal Article
Closed access
LJL. Johnson
L. Johnson
JMJ. Mozingo
J. Mozingo
PAP. Atkins
P. Atkins
SSS. Schwab
S. Schwab
AMA. Morris
A. Morris
AAA. Anderson
A. Anderson
Legg-Calvé-Perthes Disease (LCPD) often results in a permanent residual hip deformity, with long-term impacts on hip function. In the clinic, decisions on how to manage LCPD deformity are based on 2D radiographic measures such as the Stulberg grades. It is unclear whether these measures accurately represent complex, patient-specific 3D deformity, making it difficult to determine the best treatment approach. Statistical shape modeling (SSM) provides an objective and compact description of variability, but there is currently no 3D SSM that focuses solely on describing shape variability in LCPD. In this study, we have constructed an SSM of femurs with LCPD deformity, which will provide a foundation for future research into how deformity is measured in the clinic. Clinical magnetic resonance (MR) images (N=13 hips, 11 patients, 3 F/8 M) of affected hips were obtained in patients with stage IV LCPD (age range: 6–12 years, estimated Stulberg grades: II-V). MR volumes were resampled isotropically to the smallest voxel dimension (.47 – .63 mm), and two raters manually segmented the proximal femurs. ShapeWorks (SCI Institute, University of Utah, Salt Lake City, UT) was used to produce an SSM with 512 particles using an incremental optimization routine: corresponding particles were initially distributed and optimized on a subset of the five most similar femurs. The mean particle distribution of the initial model was then used to initialize the remaining eight shapes, followed by an additional optimization of the particle distribution. Differences in pose and scale between shapes were removed with generalized Procrustes analysis. Modes of shape variation were quantified using principal component analysis. The first four shape modes described 87.5% of the population variability, and qualitatively captured clinically relevant variables such as femoral head width and articular-trochanteric distance (see Figure 1). A significant association (p=0.04) was observed between shape mode 4 and asphericity of the femoral head (rho=0.58). A leave-one-out cross-validation of the model demonstrated good generalizability to unseen shapes, with a mean point-to-point reconstruction error of < 1 mm if > 4 modes were included. This SSM provides a continuous, accurate, and compact representation of 3D shape variation in LCPD. Limitations to this model include a small sample size, and thus the inability to control for age. In addition to expanding this model, future work will incorporate the acetabular side to describe joint congruence, and associate shape modes with radiographic parameters. For any figures or tables, please contact the authors directly.