Hung-Ying Lin

Hung-Ying Lin

Auto-generated profile, based on publicly available information

Hung-Ying Lin

Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in Journal of the Formosan Medical Association
Verified
Journal Article
Closed access
JPJu-Hung Pan
Ju-Hung Pan
JLJang-Jaer Lee
Jang-Jaer Lee
HLHung-Ying Lin
Hung-Ying Lin
YCYi-Jane Chen
Yi-Jane Chen
CYChung-Chen Jane Yao
Chung-Chen Jane Yao
SKSang-Heng Kok
Sang-Heng Kok

1 February 2017 in Journal of the Formosan Medical Association
Verified
Journal Article
Open access
YHYu-Ping Hsieh
Yu-Ping Hsieh
HCHsin-Ming Chen
Hsin-Ming Chen
HLHung-Ying Lin
Hung-Ying Lin
HYHsiang Yang
Hsiang Yang
ZCZwei-Chieng Chang
Zwei-Chieng Chang
Transforming growth factor (TGF)-β is a key regulator in the pathogenesis of oral submucous fibrosis (OSF). Early growth response (Egr)-1 is essential for fibrotic responses to TGF-β. Because TGF-β signaling is cell-type- and context-dependent, we investigated the signaling involved in TGF-β-induced Egr-1 in primary human buccal mucosal fibroblasts (BMFs). TGF-β-induced Egr-1 and its signaling were assessed by western blotting in BMFs. Egr-1 small interfering RNA was used to define the role of Egr-1 on TGF-β-induced mRNAs of the α1- and α2-chains of type I collagen (COL1A1 and COL1A2) and acid-soluble collagen production (via Sircol collagen assay). The effects of epigallocatechin-3-gallate (EGCG) on TGF-β-induced Egr-1 protein and acid-soluble collagen were also evaluated. TGF-β1 stimulated Egr-1 production in BMFs. Pretreatment with PD98059, SP600125, SB431542, and SIS3, but not SB203580, significantly reduced TGF-β1-induced Egr-1 protein expression. Genetic targeting of Egr-1 completely inhibited TGF-β1-induced type I collagen mRNAs and collagen protein expression. EGCG fully inhibited TGF-β1-induced Egr-1 and TGF-β1-stimulated production of acid-soluble collagens. We conclude that activin receptor-like kinase (ALK)5, Smad3, extracellular signal-regulated kinase, and c-Jun N-terminal kinase are involved in the TGF-β1-induced Egr-1 protein production in BMFs. Egr-1 mediates TGF-β1-induced COL1A1 and COL1A2 mRNA expression and acid-soluble collagen production in BMFs. EGCG can block TGF-β1-induced collagen production by attenuating Egr-1 expression in BMFs. Egr-1 is a key mediator in TGF-β1-induced pathogenesis of OSF. EGCG may be useful in the prevention or treatment of OSF.

1 January 2019 in Journal of the Formosan Medical Association
Verified
Journal Article
Open access
STShang-Jye Tsai
Shang-Jye Tsai
MCMu-Hsiung Chen
Mu-Hsiung Chen
HLHung-Ying Lin
Hung-Ying Lin
CLChun-Pin Lin
Chun-Pin Lin
HCHao-Hueng Chang
Hao-Hueng Chang
Extraction of the third molar may cause post-operative complications. This study assessed whether application of pure type-1 collagen to the third molar extraction socket can reduce post-operative pain score and duration and promote socket bone healing. Fourteen patients who underwent 20 bilateral and symmetric third molar extractions were included in this study. After two tooth extractions at two different occasions in the same patient, one socket was filled with pure type-1 collagen (experimental group, n = 20) and the other socket received nothing but the blood clot (control group, n = 20). The post-operative pain score and duration, mouth-opening limitation, and the bone density at the socket site were assessed at weeks 1, 2, 4, and 8 after tooth extraction. Patients in the experimental group had a significantly lower mean post-operative pain score (2.6 ± 1.2) than patients in the control group (4.7 ± 2.0), and had a significantly shorter post-operative pain duration (2.7 ± 1.4 days) than patients in the control group (3.7 ± 1.8 days). We also observed a significantly lower frequency of mouth-opening limitation in 20 experimental-group patients (45%) than in 20 control-group patients (90%, P = 0.007). Moreover, a significantly higher mineralization ratio (10.2%) was found in the experimental socket site than in the control socket site. Application of pure type-1 collagen to the third molar extraction socket can reduce post-operative pain score and duration, decrease the frequency of mouth-opening limitation, and increase mineralization ratio at the extraction socket site.

20 January 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
DXDeqiang Xiao
Deqiang Xiao
CLChunfeng Lian
Chunfeng Lian
LWLi Wang
Li Wang
HDHannah Deng
Hannah Deng
HLHung-Ying Lin
Hung-Ying Lin
DSDinggang Shen
Dinggang Shen
Objective: To estimate a patient-specific reference bone shape model for a patient with craniomaxillofacial (CMF) defects due to facial trauma. Methods: We proposed an automatic facial bone shape estimation framework using pre-traumatic conventional portrait photos and post-traumatic head computed tomography (CT) scans via a 3D face reconstruction and a deformable shape model. Specifically, a three-dimensional (3D) face was first reconstructed from the patient's pre-traumatic portrait photos. Second, a correlation model between the skin and bone surfaces was constructed using a sparse representation based on the CT images of training normal subjects. Third, by feeding the reconstructed 3D face into the correlation model, an initial reference shape model was generated. In addition, we refined the initial estimation by applying non-rigid surface matching between the initially estimated shape and the patient's post-traumatic bone based on the adaptive-focus deformable shape model (AFDSM). Furthermore, a statistical shape model, built from the training normal subjects, was utilized to constrain the deformation process to avoid overfitting. Results and Conclusion: The proposed method was evaluated using both synthetic and real patient data. Experimental results show that the patient's abnormal facial bony structure can be recovered using our method, and the estimated reference shape model is considered clinically acceptable by an experienced CMF surgeon. Significance: The proposed method is more suitable to the complex CMF defects for CMF reconstructive surgical planning.

20 January 2024 in Journal of the Formosan Medical Association
Verified
Journal Article
Open access
HLHung-Ying Lin
Hung-Ying Lin
JYJu-Hsuan Yang
Ju-Hsuan Yang
YLYu-Ting Li
Yu-Ting Li
CCCheng-Han Chou
Cheng-Han Chou
STShang-Jye Tsai
Shang-Jye Tsai
CLChun-Pin Lin
Chun-Pin Lin
Zirconia has been a popular material in dental implantology with good biocompatibility. But few research focused on its application in implant drills. This study aimed to investigate the physical, thermal, and biological effects on using the zirconia and stainless-steel drills for implant bone site preparation. We performed a series of experiments to evaluate the physical wearing properties of zirconia and stainless-steel drills of identical diameter and similar shape. During the implant site preparation thermal test, we subjected both drills onto a resin-embedded bone, utilizing a thermal couple device without irrigation. Moreover, we conducted a cell study by collecting bone cells in vivo while preparing the implant site with both tested drills. The cell activity was evaluated through cell proliferation colorimetric analysis (XTT) and alkaline phosphatase (ALP) activity measurements. The zirconia drill outperforms the stainless-steel drill in terms of requiring less force, maintaining stability over repeated cutting tests, and generating lower temperatures during drilling (stainless-steel drill: 45.48 ± 1.31 °C; zirconia-coated drill: 32.98 ± 1.21 °C, P = 0.000247). Meanwhile, both types of drills show similar results in XTT colorimetric analysis and ALP activity test. The thermal effect study is more favorable for using the zirconia drill than the stainless-steel drill for bone preparation. Cytological analysis indicate that the zirconia drill produces a similar impact on bone cells activity as the stainless-steel drill. Therefore, we conclude that the zirconia drills offer a good cutting effect similar to currently available stainless-steel drills in various aspects.

28 August 2018 in Journal of the Formosan Medical Association
Verified
Journal Article
Open access
PDF file
HLHung Ying Lin
Hung Ying Lin
CCChun-Pin Chiang
Chun-Pin Chiang
YWYi-Ping Wang
Yi-Ping Wang
JCJulia Yu-Fong Chang
Julia Yu-Fong Chang