Ojas Pradhan

Ojas Pradhan

Auto-generated profile, based on publicly available information

Ojas Pradhan

Drexel University, United States of America

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2023 in Applied Energy
Verified
Journal Article
Closed access
ZCZhelun Chen
Zhelun Chen
Zheng D. O'NeillZheng D. O'Neill
Zheng D. O'Neill
JWJin Wen
Jin Wen
OPOjas Pradhan
Ojas Pradhan
TYTao Yang
Tao Yang
THTerry Herr
Terry Herr

4 June 2024 in Energy and Buildings
Verified
Journal Article
Closed access
JHJiajing Huang
Jiajing Huang
NGNaghmeh Ghalamsiah
Naghmeh Ghalamsiah
APAbhidnya Patharkar
Abhidnya Patharkar
OPOjas Pradhan
Ojas Pradhan
MCMengyuan Chu
Mengyuan Chu
KCKasim Selcuk Candan
Kasim Selcuk Candan

15 April 2024 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
GLGuowen Li
Guowen Li
ZYZhiyao Yang
Zhiyao Yang
YFYangyang Fu
Yangyang Fu
Zheng D. O'NeillZheng D. O'Neill
Zheng D. O'Neill
LRLingyu Ren
Lingyu Ren
JWJin Wen
Jin Wen

14 June 2022 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
JHJiajing Huang
Jiajing Huang
HYHyunsoo Yoon
Hyunsoo Yoon
OPOjas Pradhan
Ojas Pradhan
TWTeresa Wu
Teresa Wu
JWJin Wen
Jin Wen
KCKasim Selcuk Candan
Kasim Selcuk Candan
Building automatic fault detection and diagnosis (AFDD) technologies have shown great potential for energy savings. To enable AFDD, a baseline depicting the normal operation mode is needed to detect whether the building operation deviates from normality. Existing research using physics-based knowledge and models for AFDD has mainly taken a trial-and-error approach to determine if a given baseline is sufficient via empirical experiments. A mechanism to support decisions such as how many samples and what samples should be included in the baseline is currently lacking. In this study, a data-driven method for AFDD baseline construction based on information entropy is developed. The entropy is derived based on cosine similarity among typical building automation system measurements in conjunction with outdoor weather information. The performance of the proposed method is evaluated using real building data. Evaluation results indicate that the fault detection strategy adopting the proposed method has similar or better accuracy in detecting faults compared to the same fault detection strategy using the baseline construction method from the literature. In addition, the use of entropy enables the proposed method to automatically construct and assess the baseline consisting of information-rich samples.

17 November 2021
Verified
Conference Paper
Open access
OPOjas Pradhan
Ojas Pradhan
JWJin Wen
Jin Wen
YCYimin Chen
Yimin Chen
XLXing Lu
Xing Lu
MCMengyuan Chu
Mengyuan Chu
KCK. Selcuk Candan
K. Selcuk Candan
A dynamic Bayesian Network (DBN) is proposed in this study to diagnose faults for building heating, ventilating, and air-conditioning (HVAC) systems that are controlled based on American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)'s Guideline 36: High Performance Sequence of Operation for HVAC (hereinafter Guideline 36). Guideline 36 provides recommendations on supervisory-level control. HVAC systems that adopt these strategies have more comprehensive setpoint reset schedules and more advanced control logics than typical HVAC systems. It is hence of interest to understand how faults might affect the performance of HVAC systems that are controlled based on Guideline 36 and whether we can develop strategies to diagnose and isolate faults even for systems with such comprehensive control sequences. Contrarily to a Bayesian Network (BN), DBN method incorporates the temporal dependencies of fault nodes between time steps using temporal conditional probabilities. This allows fault beliefs to accumulate over time and thus improves diagnosis accuracy. In this study, the accuracy and scalability of the proposed method is evaluated using the data from a Modelica-based simulated testbed. Overall, the developed DBN shows good potential in diagnosing and isolating the root fault causes for HVAC systems that are controlled based on the Guideline 36 control sequence.

23 May 2024 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
OPOjas Pradhan
Ojas Pradhan
JWJin Wen
Jin Wen
DHDavid Hälleberg
David Hälleberg
ZCZhelun Chen
Zhelun Chen
NVNoresh Varman
Noresh Varman
Zheng D. O'NeillZheng D. O'Neill
Zheng D. O'Neill