To describe the incidence and magnitude of femoral neck fracture shortening in patients age younger than 60 years. Secondarily, to examine predictors of fracture shortening. Retrospective chart review. Level I trauma centre. Sixty-five patients with a median age of 51 years (interquartile range: 42-56 years) were included. Seventy-one percent were male, 75% were displaced fractures, and 78% were treated with cancellous screws. Internal fixation with multiple cancellous screws or sliding hip screw (SHS) + derotation screw. Radiographic femoral neck shortening at a minimum of 6 weeks after fixation. Fifty-four percent of patients had ≥5 mm of femoral neck shortening (22% had between ≥5 and 1 cm. Our findings highlight the need for further research to determine the impact of severe shortening on functional outcome and to determine if implant selection affects fracture shortening. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Background and purpose — Most often, the goal of non-geriatric femoral neck fracture surgery is to preserve the native hip joint. However, reoperations for painful implants, osteonecrosis, and nonunion are common. We determined the reoperation rate and time-to-reoperation following internal fixation of these fractures in a large population cohort. Patients and methods — This retrospective cohort study included patients between the ages of 18 and 50 years old who underwent internal fixation for a femoral neck fracture during 1997–2013. Patients were followed until December 2013. Primary outcomes were reoperation rate and time-to-reoperation. Time-to-event analysis was performed to estimate the rate of any reoperation and for THA specifically, while testing the dependency of time-to-reoperation on secondary variables. Results — 796 young femoral neck fracture patients were treated with internal fixation during the study period (median age 43 years, 39% women). Median follow-up was 8 years (IQR 4–13). One-third underwent at least 1 reoperation at a median 16 months after the index surgery (IQR 8–31). Half of reoperations were for implant removal, followed by conversion to total hip arthroplasty. 14% of the cohort were converted to THA. The median time to conversion was 2 years (IQR 1–4). Neither female sex nor older age had a statistically significant effect on time-to-reoperation or time-to-THA conversion. Interpretation — Following internal fixation of young femoral neck fracture, 1 in 3 patients required a reoperation, and 1 in 7 were converted to THA. These data should be considered by patients and surgeons during treatment decision-making.
30 July 2014 in Journal of Hand Surgery (European Volume)
This article critically and systematically reviews the surgical treatments for ulnar impaction syndrome. Three types of treatments currently exist: arthroscopic wafer procedure, open wafer procedure, and ulna shortening osteotomy. A total of 36 articles were included from searching the electronic databases PubMed MEDLINE, Ovid MEDLINE, and Ovid EMBASE. Studies were evaluated for quality using the Modified Detsky Score. Of these, 14 articles had a Modified Detsky Score of 6/10 or higher. Satisfaction rates were 100% for arthroscopic wafer procedure, 89% for open wafer procedure, and 84% for ulna shortening osteotomy. The percentage of participants reporting an excellent or good outcome was 82% for arthroscopic wafer procedure, 87% for open wafer procedure, and 76% for ulna shortening osteotomy. In conclusion, available evidence shows that arthroscopic wafer procedure and open wafer procedure may be viable alternatives to the more popular ulna shortening osteotomy, but clinical superiority is yet to be established. Future research should focus on prospective cohort methods and should report participant outcomes using validated scoring methods.
1 April 2017 in Journal of the American Academy of Orthopaedic Surgeons
Introduction: Although femoral neck fractures in young patients are rare and their complications are well-documented, there is a paucity of data on patient-reported outcomes for this population. The purpose of this study was to describe the quality of life and the effect of clinical complications on the outcomes of young patients with femoral neck fractures in a Chinese cohort. Methods: In this prospective observational cohort study, patients aged 18 to 55 years admitted to one of three participating trauma hospitals in China for treatment of a femoral neck fracture were recruited. The primary outcome was the patient’s health-related quality of life using the Medical Outcomes Study 36-Item Short Form (SF-36) Health Survey at 1 year after injury. Associations between the primary outcome and potential predictors were explored with univariate and multivariate regression analysis. Results: One hundred seven patients (mean age, 44 years) completed 1-year follow-up. Nearly all patients were treated with closed reduction and screw fixation. Nine cases of nonunion, 7 cases of malunion, and 11 cases of osteonecrosis were identified. The mean SF-36 Physical Component Score was 48.6 ± 8.5, and the mean Mental Component Score was 51.0 ± 7.4. Fracture displacement, quality of reduction, and nonunion were associated with a poor Physical Component Score outcome. Discussion: Our results demonstrate that the quality of life for patients after closed reduction and screw fixation of femoral neck fractures is similar to that of the general population, particularly when complications of nonunion and malunion are avoided. Level of Evidence: Level I
The primary purpose of this study was to describe the failure patterns of femoral neck fracture fixation in young patients. The secondary purpose was to determine if pattern of failure varies by type of implant. Adult patients (age range, 18–55 years) who experienced a “fixation failure” following internal fixation of a femoral neck fracture were identified from 5 level 1 trauma centers. Failure was defined by screw cutout, implant breakage, varus collapse (<120° neck-shaft angle), or severe fracture shortening (≥1 cm). When multiple complications were identified, mechanical failures were preferentially noted for the analysis. Failure patterns were compared between patients who received multiple cancellous screws and patients who received a sliding hip screw plus a derotation screw. Severe fracture shortening was the most common complication identified (61%). No differences in the incidence of severe shortening ( P =.750) or implant breakage ( P =1.000) were detected between the fixation groups. However, among the failures with a sliding hip screw plus a derotation screw construct, a greater portion were related to screw cutout (38% for a sliding hip screw plus a derotation screw vs 7% for screws, P =.019). Failures with multiple screws were associated with varus collapse (25% for screws vs 0% for a sliding hip screw plus a derotation screw, P =.037). Severe shortening was the most common fixation failure. Sliding hip screw plus derotation screw implants were associated with screw cutout. Multiple cancellous screw implants failed by varus collapse. Selecting a surgical implant based on its likely failure pattern may allow surgeons to minimize the severity of failure or the need for secondary conversion to hip arthroplasty. [ Orthopedics. 2019; 42(4):e376–e380.]