Chest X-rays (CXRs) can help triage for Coronavirus disease (COVID-19) patients in resource-constrained environments, and a computer-aided detection system (CAD) that can identify pneumonia on CXR may help the triage of patients in those environment where expert radiologists are not available. However, the performance of existing CAD for identifying COVID-19 and associated pneumonia on CXRs has been scarcely investigated. In this study, CXRs of patients with and without COVID-19 confirmed by reverse transcriptase polymerase chain reaction (RT-PCR) were retrospectively collected from four and one institution, respectively, and a commercialized, regulatory-approved CAD that can identify various abnormalities including pneumonia was used to analyze each CXR. Performance of the CAD was evaluated using area under the receiver operating characteristic curves (AUCs), with reference standards of the RT-PCR results and the presence of findings of pneumonia on chest CTs obtained within 24 hours from the CXR. For comparison, 5 thoracic radiologists and 5 non-radiologist physicians independently interpreted the CXRs. Afterward, they re-interpreted the CXRs with corresponding CAD results. The performance of CAD (AUCs, 0.714 and 0.790 against RT-PCR and chest CT, respectively hereinafter) were similar with those of thoracic radiologists (AUCs, 0.701 and 0.784), and higher than those of non-radiologist physicians (AUCs, 0.584 and 0.650). Non-radiologist physicians showed significantly improved performance when assisted with the CAD (AUCs, 0.584 to 0.664 and 0.650 to 0.738). In addition, inter-reader agreement among physicians was also improved in the CAD-assisted interpretation (Fleiss’ kappa coefficient, 0.209 to 0.322). In conclusion, radiologist-level performance of the CAD in identifying COVID-19 and associated pneumonia on CXR and enhanced performance of non-radiologist physicians with the CAD assistance suggest that the CAD can support physicians in interpreting CXRs and helping image-based triage of COVID-19 patients in resource-constrained environment.
Background: Many COVID-19 patients rapidly progress to respiratory failure with a broad range of severities. Identification of high-risk cases is critical for early intervention. Objective: The aim of this study is to develop deep learning models that can rapidly identify high-risk COVID-19 patients based on computed tomography (CT) images and clinical data. Methods: We analyzed 297 COVID-19 patients from five hospitals in Daegu, South Korea. A mixed artificial convolutional neural network (ACNN) model, combining an artificial neural network for clinical data and a convolutional neural network for 3D CT imaging data, was developed to classify these cases as either high risk of severe progression (ie, event) or low risk (ie, event-free). Results: Using the mixed ACNN model, we were able to obtain high classification performance using novel coronavirus pneumonia lesion images (ie, 93.9% accuracy, 80.8% sensitivity, 96.9% specificity, and 0.916 area under the curve [AUC] score) and lung segmentation images (ie, 94.3% accuracy, 74.7% sensitivity, 95.9% specificity, and 0.928 AUC score) for event versus event-free groups. Conclusions: Our study successfully differentiated high-risk cases among COVID-19 patients using imaging and clinical features. The developed model can be used as a predictive tool for interventions in aggressive therapies.
Background: An artificial intelligence (AI) model using chest radiography (CXR) may provide good performance in making prognoses for COVID-19. Objective: We aimed to develop and validate a prediction model using CXR based on an AI model and clinical variables to predict clinical outcomes in patients with COVID-19. Methods: This retrospective longitudinal study included patients hospitalized for COVID-19 at multiple COVID-19 medical centers between February 2020 and October 2020. Patients at Boramae Medical Center were randomly classified into training, validation, and internal testing sets (at a ratio of 8:1:1, respectively). An AI model using initial CXR images as input, a logistic regression model using clinical information, and a combined model using the output of the AI model (as CXR score) and clinical information were developed and trained to predict hospital length of stay (LOS) ≤2 weeks, need for oxygen supplementation, and acute respiratory distress syndrome (ARDS). The models were externally validated in the Korean Imaging Cohort of COVID-19 data set for discrimination and calibration. Results: The AI model using CXR and the logistic regression model using clinical variables were suboptimal to predict hospital LOS ≤2 weeks or the need for oxygen supplementation but performed acceptably in the prediction of ARDS (AI model area under the curve [AUC] 0.782, 95% CI 0.720-0.845; logistic regression model AUC 0.878, 95% CI 0.838-0.919). The combined model performed better in predicting the need for oxygen supplementation (AUC 0.704, 95% CI 0.646-0.762) and ARDS (AUC 0.890, 95% CI 0.853-0.928) compared to the CXR score alone. Both the AI and combined models showed good calibration for predicting ARDS (P=.079 and P=.859). Conclusions: The combined prediction model, comprising the CXR score and clinical information, was externally validated as having acceptable performance in predicting severe illness and excellent performance in predicting ARDS in patients with COVID-19.
1 January 2023 in Dental Press Journal of Orthodontics
Objective: This study was designed to analyze and compare the cusp and apex movements of the maxillary canines and first molars during canine retraction in the first step of extraction space closure, and to evaluate if these teeth follow a curvilinear (acceleration and/or deceleration) movement rate. Material and Methods: Twenty-five patients (23.3 ± 5.1 years of age) were enrolled. The retraction of the maxillary canines was accomplished using nickel-titanium closed coil springs (100gf) on 0.020-in stainless steel archwire. Oblique cephalograms were traced and superimposed on the anatomic best fit of the maxilla (before the retraction [T0], and after one month [T1], three [T3], five [T5] and seven [T7] months). Statistics was based in a normally distributed data. Multilevel procedures were used to derive polynomials for each of the measurements. Student’s t-test and one-way repeated measures ANOVA were conducted. The level of significance of 5% was adopted. Results: Canine cusps and apexes did not follow a quadratic curve regarding horizontal movement (neither accelerate nor decelerate). Canine and molar cusps showed more horizontal movement than apexes (4.80 mm vs. 2.78 mm, and 2.64 mm vs. 2.17 mm, respectively). Conclusions: Canine did not accelerate or decelerate overtime horizontally; the cusps and apexes of the canines and molars showed more horizontal movement and larger rate at the beginning of canine retraction, followed by significantly smaller and constant movement rate after the first month.