1 August 2017 in American Journal of Obstetrics and Gynecology
Prediction of neonatal respiratory morbidity may be useful to plan delivery in complicated pregnancies. The limited predictive performance of the current diagnostic tests together with the risks of an invasive procedure restricts the use of fetal lung maturity assessment. The objective of the study was to evaluate the performance of quantitative ultrasound texture analysis of the fetal lung (quantusFLM) to predict neonatal respiratory morbidity in preterm and early-term (<39.0 weeks) deliveries. This was a prospective multicenter study conducted in 20 centers worldwide. Fetal lung ultrasound images were obtained at 25.0-38.6 weeks of gestation within 48 hours of delivery, stored in Digital Imaging and Communication in Medicine format, and analyzed with quantusFLM. Physicians were blinded to the analysis. At delivery, perinatal outcomes and the occurrence of neonatal respiratory morbidity, defined as either respiratory distress syndrome or transient tachypnea of the newborn, were registered. The performance of the ultrasound texture analysis test to predict neonatal respiratory morbidity was evaluated. A total of 883 images were collected, but 17.3% were discarded because of poor image quality or exclusion criteria, leaving 730 observations for the final analysis. The prevalence of neonatal respiratory morbidity was 13.8% (101 of 730). The quantusFLM predicted neonatal respiratory morbidity with a sensitivity, specificity, positive and negative predictive values of 74.3% (75 of 101), 88.6% (557 of 629), 51.0% (75 of 147), and 95.5% (557 of 583), respectively. Accuracy was 86.5% (632 of 730) and positive and negative likelihood ratios were 6.5 and 0.3, respectively. The quantusFLM predicted neonatal respiratory morbidity with an accuracy similar to that previously reported for other tests with the advantage of being a noninvasive technique.
1 July 2015 in Reproductive Sciences
17 March 2017 in Reproductive Sciences
AFAlejandro Figueroa-Quiñones
Alejandro Figueroa-Quiñones
+2
24 November 2010 in Ultrasound in Obstetrics & Gynecology
30 June 2010 in Archives of Gynecology and Obstetrics
28 November 2014 in The Journal of Maternal-Fetal & Neonatal Medicine
MFMaría A. Fajardo-Expósito
María A. Fajardo-Expósito
Objective: To evaluate the influence of both uterine and umbilical arteries Doppler pulsatility indexes (PI) and metabolic control on birthweight in pregnant women with gestational diabetes mellitus. Methods: One hundred sixty-nine women with gestational diabetes were evaluated. Doppler measurements of umbilical artery and mean uterine arteries PI were recorded and the corresponding Z-score values by gestational age calculated. Maternal pregestational body mass index (BMI) and the levels of glycosylated hemoglobin were also recorded. The relationships between these studied variables and customised birthweight centiles according to sex and gestational age were analyzed using Spearman’s correlation coefficient and linear regression. Results: There was a significant correlation between birthweight centiles and Z-score values of the umbilical artery PI (r = −0.25, p = 0.001), but not with the Z-score values of the uterine artery PI (r = −0.12, p = 0.43). Third trimester maternal glycosylated hemoglobin was also positively correlated to birthweight (r = 0.29, p = 0.01). When using stepwise linear regression both maternal glycosylated hemoglobin and the Z-score of umbilical artery PI were included as independent variables in the predictive model of birthweight centile (p = 0.0002, p = 0.001 respectively, R2 = 0.27). Conclusions: Umbilical artery PI predicts birthweight in women with gestational diabetes. However, metabolic control is the only important determinant of fetal macrosomia in these mothers.