Hironori Shigeta

Hironori Shigeta

Auto-generated profile, based on publicly available information

Hironori Shigeta

Graduate School of Information Science and Technology, The University of Osaka, Suita, Japan

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021
Verified
Conference Paper
Open access
KFKenji Fujimoto
Kenji Fujimoto
TMTsubasa Mizugaki
Tsubasa Mizugaki
URUtkrisht Rajkumar
Utkrisht Rajkumar
HSHironori Shigeta
Hironori Shigeta
SSShigeto Seno
Shigeto Seno
HMHideo Matsuda
Hideo Matsuda
Cell migration is one of the important criteria for determining effects on cells by inflammatory and/or chemical stimulation. Accurate detection of cells' movement through traditional methods, such as optical flow, is difficult because those cells' fluorescence intensity and shapes are similar to each other. Therefore, we adopt a tracking approach based on a convolutional neural network (CNN) using time-lapse multi-slice images observed with 2-photon excitation microscopy. Existing CNN-based cell tracking methods are often focusing on tracking targets in the 2-dimensional (2D) space since the costs for computation and annotation drastically increase in 3-dimensional (3D) settings. Those methods usually convert the 3D microscopic images to the 2D ones via maximum intensity projection (MIP). However, as MIP does not keep the depth information, it is difficult to track depth-directionally overlapping cells in MIP images accurately. To cope with the problem, we propose a novel CNN-based cell tracking method for multi-slice 3D images. Our method trains a CNN using MIP images annotated with the cell locations, similarly to the existing methods. Meanwhile, in the tracking phase, our method estimates not only each cell's location but its depth using multiple slices at different depths. Using our method, we track leukocyte migration in multi-slice time-lapse images observed with 2-photon excitation microscopy. As a result, we show that our method outperforms existing cell tracking methods including multi-domain network (MDNet) with MIP images.


15 June 2023
Verified
Conference Paper
Open access
TNToru Nagamura
Toru Nagamura
SSShigeto Seno
Shigeto Seno
HSHironori Shigeta
Hironori Shigeta
Tomohiro MashitaTomohiro Mashita
Tomohiro Mashita
HMHideo Matsuda
Hideo Matsuda
Recent advances in optical microscopy and fluorescent protein technology have made it possible to record movies of cells over time while keeping them alive. Cell tracking is necessary to extract and analyze cell dynamics from these movies. Tracking-by-detection methods based on supervised deep learning are widely used for cell tracking. However, it is necessary to individually adjust the tracking algorithm for each cell movie that shows various characteristics and, in addition, to prepare a sufficient amount of data for training. To address these issues, we propose a method for training cell tracking models based on reinforcement learning with a simulator that imitates cell movies as an environment. The simulator can generate diverse and voluminous cell movies containing cell features from the correct trajectory of cell tracking. Through evaluation of the Cell Tracking Challenge dataset, the proposed method is confirmed to achieve a competitive performance that is better than the conventional reinforcement-learning tracker.

22 January 2026 in JMIR Medical Informatics
Verified
Journal Article
Open access
TNTomoaki Nakano
Tomoaki Nakano
KOKeita Okayama
Keita Okayama
MYMasanao Yasuoka
Masanao Yasuoka
HSHironori Shigeta
Hironori Shigeta
AKAkito Kawamura
Akito Kawamura
YSYasushi Sakata
Yasushi Sakata
Background: Long-term garment-type wearable Holter electrocardiographic (ECG) monitoring is frequently affected by noise contamination, which complicates automated atrial fibrillation (AF) detection in real-world recordings. Although deep learning has shown high performance for AF detection, relatively few studies have evaluated explicit strategies for handling noise-included wearable ECG data. An alternative representation using the R-R interval (RRI) time series may reduce the dependence on waveform morphology and provide an alternative pathway for AF screening in noisy recordings. Objective: This study aimed to develop and evaluate a 3-class, noise-aware RRI-based AF screening framework that explicitly separated AF, non-AF, and uninterpretable noise windows, and to assess the impact of analysis window length on model performance. Methods: Single-lead garment-type wearable Holter ECG data from 117 patients at the University of Osaka Hospital were analyzed after exclusion of patients with documented atrial tachycardia, flutter, or paced rhythm according to the predefined task definition. R-peaks were automatically detected, and the resulting RRI segments were converted into 2D histogram images, with time on the x-axis and RRI-derived heart rate on the y-axis, for 1.5-, 3-, and 6-minute windows. A ResNet-34–based 2D convolutional neural network was trained for 3-class classification. Model performance was evaluated using 5-fold interpatient cross-validation on the institutional dataset and independent external testing on the MIT-BIH (Massachusetts Institute of Technology–Beth Israel Hospital) AF Database (AFDB). In the external validation, atrial flutter–annotated intervals were excluded to match the training task definition. Patient-level AF burden was evaluated by comparing reference AF burden with model-estimated AF burden using Pearson and Spearman correlation coefficients, and linear regression. Results: Of 129 monitored patients between March 1, 2023, and November 20, 2025, 117 were analyzed. In the internal validation, the 3-class model (non-AF, AF, and noise) showed similarly high performance for the 1.5- and 3 -minute windows, both with an accuracy of 96.6%. In independent external validation, the 3-minute window showed numerically the highest overall performance (accuracy: 97.3%; AF sensitivity: 96.9%; and AF specificity: 97.7%), although the differences across window lengths were modest. At the patient level, AF burden correlation was high across all window lengths, with Pearson r of 0.995, 0.991, and 0.989 and Spearman ρ of 0.988, 0.982, and 0.979 for the 1.5-, 3-, and 6-minute models, respectively. Conclusions: The RRI-based 2D convolutional neural network achieved high AF classification accuracy and strong patient-level correlation with reference AF burden. Using RRI features and a 3-class framework, which explicitly separated noise from AF and non-AF rhythms, a 3-minute RRI window provided a favorable balance of performance for AF screening in a garment-type Holter ECG.

22 January 2026 in JMIR Preprints
Verified
Preprint
Open access
TNTomoaki Nakano
Tomoaki Nakano
KOKeita Okayama
Keita Okayama
MYMasanao Yasuoka
Masanao Yasuoka
HSHironori Shigeta
Hironori Shigeta
AKAkito Kawamura
Akito Kawamura
YSYasushi Sakata
Yasushi Sakata
BACKGROUND Atrial fibrillation (AF) is a significant contributor to cardioembolic stroke, necessitating early and precise detection of AF to mitigate associated risks. Long-term Holter electrocardiography (ECG) monitoring using garment-type wearable devices produces large volumes of single-lead data with various noise artifacts. Deep learning has achieved high performance in AF detection from ECG data; however, many deep learning studies report strong performance on curated datasets or noise-controlled recordings. Comparatively fewer approaches have been developed and evaluated with an explicit strategy to maintain diagnostic accuracy in noise-included real-world wearable Holter ECG data. An alternative representation using the R–R interval (RRI) time series may reduce the dependence on waveform morphology and provide a computationally efficient pathway for robust AF screening in noisy recordings. OBJECTIVE This study aims to develop a computationally efficient, noise-robust deep learning model that leverages the irregularity of the RRI in noisy wearable monitoring environments. We evaluated the impact of the analysis window length on model performance. METHODS Single-lead Holter ECG data from 117 patients at the University of Osaka Hospital were analyzed, excluding those with atrial tachycardia/flutter. The RRIs were extracted, segmented into 1.5-, 3-, and 6-min windows, and transformed into two-dimensional histogram images. A ResNet-34–based two-dimensional convolutional neural network (2D-CNN) was trained for three-class classification. The model performance was evaluated using five-fold inter-patient cross-validation and externally validated using the MIT-BIH AF Database. Patient-level AF burden was defined as the proportion of AF duration relative to total analyzable recording time per patient; agreement between cardiologist-derived and model-estimated AF burden was assessed using Pearson’s correlation coefficient and linear regression. RESULTS Of 129 monitored patients (Feb 1, 2023–Nov 20, 2025), 117 were analyzed. In the internal validation, the 3-min window had superior performance (accuracy, 96.9%; AF sensitivity, 97.0%; AF specificity, 98.2%). External validation corroborated this balance (accuracy, 96.1%; AF sensitivity, 93.3%; and AF specificity, 98.7%). The 3-min model exhibited an exceptionally high correlation with the reference AF burden (r = 0.988, R² = 0.976). CONCLUSIONS The RRI-based 2D-CNN achieved high AF classification accuracy and excellent agreement with AF burden. By utilizing RRI features and a noise-adaptive training strategy, a 3-min RRI window has emerged as a practical solution for efficient AF screening in a garment-type Holter ECG.