21 May 2021 in Science Advances
The lack of available table-top extreme ultraviolet (XUV) sources with high enough fluxes and coherence properties has limited the availability of nonlinear XUV and x-ray spectroscopies to free-electron lasers (FELs). Here, we demonstrate second harmonic generation (SHG) on a table-top XUV source by observing SHG near the Ti M2,3 edge with a high-harmonic seeded soft x-ray laser. Furthermore, this experiment represents the first SHG experiment in the XUV. First-principles electronic structure calculations suggest the surface specificity and separate the observed signal into its resonant and nonresonant contributions. The realization of XUV-SHG on a table-top source opens up more accessible opportunities for the study of element-specific dynamics in multicomponent systems where surface, interfacial, and bulk-phase asymmetries play a driving role.
2 March 2023 in Nature Photonics
26 April 2021 in Journal of Optics
We report a straightforward method to control main spatio-temporal couplings in a chirped pulse amplification (CPA) laser chain system using a specially designed chromatic doublet in a divergent beam configuration. The centering of the doublet allows for the control of the spatial chirp of the CPA laser chain, while its longitudinal position in the divergent beam enables the control of the amount of longitudinal chromatism in a wide dynamic range. The performance of this technique is evaluated by measuring main spatio-temporal couplings with a simple method, based on an ultrafast pulse shaper, which allows for a selection of narrow windows of the spectrum.
18 July 2022 in Physical Review Research
We report the first experimental measurement of a strong pulse shortening of a seeded plasma-based soft x-ray laser at high electron densities. As a consequence of the gain gating caused by subsequent collisional ionization, the duration drops from 1.4 ps to an unprecedented value of 520 fs RMS when the electron density increases from 4 to . These measurements, performed with an original single-shot method, are in good agreement with results from 3D Maxwell-Bloch simulations.
1 October 2020 in Review of Scientific Instruments
We report a straightforward beam splitter in the soft x-ray spectral range using a thin oxidized aluminum foil. As it allows us to monitor reliably shot-to-shot variations in energy and in energy distribution, this beam splitter is of high interest for the simultaneous use of diagnostics for soft x-rays sources. We measure a transmission of 0.5 and a reflectivity of 0.018 at 22.5° of incidence with a soft x-ray laser working at 32.8 nm. These values are in good agreement with the theory. As the theory predicts a reflectivity and a transmission of both 12% at 52.5° of incidence for 32.8 nm, it can also be useful for experiments that require the division and recombination of a beam, for instance, interferometry or pump-probe technique with an intense soft x-ray source.