17 July 2018 in Chemistry of Materials
9 January 2017 in The Journal of Physical Chemistry Letters
18 October 2021 in Journal of Synchrotron Radiation
The optical design and performance of the recently opened 13A biological small-angle X-ray scattering (SAXS) beamline at the 3.0 GeV Taiwan Photon Source of the National Synchrotron Radiation Research Center are reported. The beamline is designed for studies of biological structures and kinetics in a wide range of length and time scales, from angstrom to micrometre and from microsecond to minutes. A 4 m IU24 undulator of the beamline provides high-flux X-rays in the energy range 4.0–23.0 keV. MoB4C double-multilayer and Si(111) double-crystal monochromators (DMM/DCM) are combined on the same rotating platform for a smooth rotation transition from a high-flux beam of ∼4 × 1014 photons s−1 to a high-energy-resolution beam of ΔE/E ≃ 1.5 × 10−4; both modes share a constant beam exit. With a set of Kirkpatrick–Baez (KB) mirrors, the X-ray beam is focused to the farthest SAXS detector position, 52 m from the source. A downstream four-bounce crystal collimator, comprising two sets of Si(311) double crystals arranged in a dispersive configuration, optionally collimate the DCM (vertically diffracted) beam in the horizontal direction for ultra-SAXS with a minimum scattering vector q down to 0.0004 Å−1, which allows resolving ordered d-spacing up to 1 µm. A microbeam, of 10–50 µm beam size, is tailored by a combined set of high-heat-load slits followed by micrometre-precision slits situated at the front-end 15.5 m position. The second set of KB mirrors then focus the beam to the 40 m sample position, with a demagnification ratio of ∼1.5. A detecting system comprising two in-vacuum X-ray pixel detectors is installed to perform synchronized small- and wide-angle X-ray scattering data collections. The observed beamline performance proves the feasibility of having compound features of high flux, microbeam and ultra-SAXS in one beamline.
27 August 2024 in ACS Nano
12 July 2018 in The Journal of Physical Chemistry Letters
25 July 2023 in Journal of Applied Crystallography
Liposome development is of great interest owing to increasing requirements for efficient drug carriers. The structural features and thermal stability of such liposomes are crucial in drug transport and delivery. Reported here are the results of the structural characterization of PEGylated liposomes via small- and wide-angle X-ray scattering and an asymmetric flow field-flow fractionation (AF4) system coupled with differential refractive-index detection, multi-angle light scattering (MALS) and dynamic light scattering. This integrated analysis of the exemplar PEGylated liposome formed from hydrogenated soy phosphatidylcholine (HSPC) with the addition of cholesterol reveals an average hydrodynamic radius (R h) of 52 nm with 10% polydispersity, a comparable radius of gyration (R g) and a major liposome particle mass of 118 kDa. The local bilayer structure of the liposome is found to have asymmetric electronic density profiles in the inner and outer leaflets, sandwiched by two PEGylated outer layers ca 5 nm thick. Cholesterol was found to effectively intervene in lipid chain packing, resulting in the thickening of the liposome bilayer, an increase in the area per lipid and an increase in liposome size, especially in the fluid phase of the liposome. These cholesterol effects show signs of saturation at cholesterol concentrations above ca 1:5 cholesterol:lipid molar ratio.