Purpose: Although commercial optical coherence tomography angiography (OCTA) machines quantitate retinal vascular density (VD) by dividing the vasculature into superficial and deep capillary plexus (SCP, DCP), histology reveals three distinct plexus layers. This study tested the hypothesis that the VD measurement of three distinct retinal plexus layers obtained using custom segmentation has high repeatability comparable to that of automatically segmented SCP and DCP layers. Materials and Methods: Forty-four participants (86 eyes) were enrolled – 54 eyes with retinal vasculopathy and 25 eyes with macular edema. Macular OCTA images (3x3 mm and 6x6 mm) were obtained twice within 30 minutes by the same personnel using the same instrument (AngioVue, Optovue, version 2018.0.0.18). The intraclass correlation coefficient (ICC) was calculated to access repeatability. Results: The repeatability of VD for SCP and DCP was good-to-moderate (ICC=0.65– 0.85) and minimally affected by image quality, retinal vasculopathy, or macular edema. The repeatability of the VD of the custom-segmented intermediate and deep plexus layers (cICP and cDCP) was poor/moderate (ICC=0.40– 0.74) but better in the subset without macular edema using 3x3 mm scans with good images quality (ICC=0.58– 0.93). Repeatability of cICP and cDCP VD measurement for 6x6 mm scans was poor (ICC≤ 0.5) in eyes with retinal vasculopathy and/or macular edema. Conclusion: Although repeatability of the VD measurement is high for the automatically segmented SCP and DCP, repeatability of VD is poor for the cICP and cDCP using larger scans in eyes with retinal vasculopathy and/or macular edema.
Purpose: The study aims to investigate the ease of use, acceptability, and accuracy of a simple at-home vision screening kit in a non-English speaking socially disadvantaged population. Design: This is a single site, prospective, cross-sectional study. Methods: Patients at a clinic that provided free medical care to an urban, predominantly Asian, underserved population were invited to participate in this study. We designed a program for at-home vision assessment, which consisted of a simple at-home vision kit (Rosenbaum near card, Amsler grid) and instructions for use given in verbal and written form in the patient’s own language. Testing was performed in each eye during an in-person visit. Patients were then asked to test at-home and were later contacted by telephone to record the results. A survey questionnaire assessing the ease of use and acceptability of the vision kit was then administered. Results: One hundred and one of 141 patients completed the study. Of those patients, 60.4% were female, 79.2% were Asian, 95% were born outside of the United States, 81.2% did not speak English as their primary language, 47.5% were not enrolled in health insurance, and 67.3% expressed difficulty in accessing eye care. The results of our survey (n = 101) demonstrated that 90% would continue utilizing the vision screening kit, 91.1% would recommend the vision screening kit to others, and 82.2% rated the vision screening kit as extremely easy to use. The Spearman’s rank correlation coefficient for the in-person VA logMAR scores and at-home VA logMAR scores was calculated to be ρ = 0.862, p < 0.0001 in the right eye and ρ = 0.834, p < 0.0001 in left eye. Conclusion: Our tailored protocol and design of a simple at-home vision screening kit was widely accepted and easy to use by an underserved population in which English was not the primary spoken language. The kit demonstrated excellent correlation between in-person and at-home VA results.