Zhiqiang Xu

Zhiqiang Xu

Auto-generated profile, based on publicly available information

Zhiqiang Xu

School of Electronics and Computer Science, University of Southampton, Southampton, United Kingdom

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in CSEE Journal of Power and Energy Systems
Verified
Journal Article
Open access
PDF file
GCGeorge Chen
George Chen
MHMiao Hao
Miao Hao
ZXZhiqiang Xu
Zhiqiang Xu
AVAlun Vaughan
Alun Vaughan
JCJunzheng Cao
Junzheng Cao
HWHaitian Wang
Haitian Wang
Increased renewable energy integration and international power trades have led to the construction and development of new HVDC transmission systems. HVDC cables, in particular, play an important role in undersea power transmission and offshore renewa...

15 August 2011 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
TZTian-Chun Zhou
Tian-Chun Zhou
GCGeorge Chen
George Chen
RLRui-Jin Liao
Rui-Jin Liao
ZXZhiqiang Xu
Zhiqiang Xu
Space charge formation in polymeric materials can cause some serious concern for design engineers as the electric field may severely be distorted, leading to part of the material being overstressed. This may result in material degradation and possibly premature failure at the worst. It is therefore important to understand charge generation, trapping, and detrapping processes in the material. Trap depths and density of trapping states in materials are important as they are potentially related to microstructure of the material. Changes in these parameters may reflect the aging taken place in the material. In the present paper, characteristics of charge trapping and detrapping in low density polyethylene (LDPE) under dc electric field have been investigated using the pulsed electroacoustic (PEA) technique. A simple trapping and detrapping model based on two trapping levels has been used to qualitatively explain the observation. Numerical simulation based on the above model has been carried out to extract parameters related to trapping characteristics in the material. It has been found that the space charge decaying during the first few hundred seconds corresponding to the fast changing part of the slope was trapped with the shallow trap depth 0.88 eV, with trap density 1.47 × 1020 m−3 in the sample volume measured. At the same time, the space charge that decays at longer time corresponding to the slower part of the slope was trapped with the deep trap depth 1.01 eV, with its trap density 3.54 × 1018 m−3. The results also indicate that trap depths and density of both shallow and deep traps may be used as aging markers as changes in the material will certainly affect trapping characteristics in terms of trap depth and density.

2 November 2007 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
ZXZhiqiang Xu
Zhiqiang Xu
LZLinwen Zhang
Linwen Zhang
GCGeorge Chen
George Chen

15 December 2010 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
JZJ. Zhao
J. Zhao
ZXZ. Xu
Z. Xu
GCG. Chen
G. Chen
PLPaul Lewin
Paul Lewin
Space charge in polyethylene-based insulation materials and its effect on the local electric field under a dc environment have been extensively examined over the last few decades while the behavior of space charge under ac stress has received less attention. Space charge phenomenon under ac electric fields becomes an important issue with increased operating field strength in many applications, such as next generation high voltage cables. In this paper, a bipolar charge transport model has been developed to simulate space charge in polymers under ac electric fields. Obtained simulation results show that there is a small quantity of phase-dependent bipolar charge accumulation in the vicinity of the electrodes that does not move into the bulk under ac stress. This causes a slight distortion of the local field in the bulk. However, at lower frequencies less than 1 Hz, there is increased charge accumulation and penetration. Comparison with available experimental data suggests that the model is capable of describing the underlying physics of charge behavior when a dielectric material is subjected to ac electric fields. Due to the weak charge movement in the bulk, the conduction current density is small and hence the displacement component dominates the total current density and this increases linearly with ac frequency.

18 January 2016 in Energies
Verified
Journal Article
Open access
PDF file
CTChao Tang
Chao Tang
BHBo Huang
Bo Huang
MHMiao Hao
Miao Hao
ZXZhiqiang Xu
Zhiqiang Xu
JHJian Hao
Jian Hao
GCGeorge Chen
George Chen
This paper focuses on the space charge behavior in oil-paper insulation systems used in power transformers. It begins with the importance of understanding the space charge behavior in oil-paper insulation systems, followed by the introduction of the pulsed electrostatic technique (PEA). After that, the research progress on the space charge behavior of oil-paper insulation during the recent twenty years is critically reviewed. Some important aspects such as the environmental conditions and the acoustic wave recovery need to be addressed to acquire more accurate space charge measurement results. Some breakthroughs on the space charge behavior of oil-paper insulation materials by the research team at the University of Southampton are presented. Finally, future work on space charge measurement of oil-paper insulation materials is proposed.

6 March 2019 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
BHBo Huang
Bo Huang
ZXZhiqiang Xu
Zhiqiang Xu
MHMiao Hao
Miao Hao
GCGeorge Chen
George Chen
Space charge build-up has been considered as the major issue in the development of HVDC apparatus such as the converter transformer. The existence of space charge can distort the local electric field, which could lead to the degradation and even breakdown of insulation materials. Therefore, it is vital to investigate factors that can affect space charge formation and dissipation characteristics such as the temperature, moisture, ageing, thickness, multi-layered structure and electric fields. This paper mainly focuses on the effect of multilayers and thickness on space charge behaviour of oil and pressboard insulation system. Space charge was measured using the pulsed electroacoustic technique (PEA) method. The space charge results are quantitatively analysed to establish the relationship between interfacial charge density and different pressboard and oil thickness ratios. A new space charge interpolation methodology is utilized to input space charge into the multilayers oil and pressboard model using COMSOL software. The local electric field of multilayers oil-impregnated pressboard and oil could be simulated, with the emphasis on the electric field after the polarity reversal operation. From space charge results, they indicate that the increased thickness of pressboard could prohibit the interfacial charge increase while the increased oil thickness could facilitate interfacial charge increase. Moreover, from the electric field simulation results, they indicate that there is the electric field gradient caused by the space charge for multilayers oil and oil-impregnated pressboard structure. After the polarity reversal, the maximum electric field of the oil caused by the space charge is higher than electric field calculated based on the Maxwell-Wagner theory.