Lik-Kwan Shark

Lik-Kwan Shark

Auto-generated profile, based on publicly available information

Lik-Kwan Shark

Institute for Engineering, Technology and Innovation (InETI), University of Lancashire

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2011 in Medical Engineering & Physics
Verified
Journal Article
Closed access
LSL.-K. Shark
L.-K. Shark
HCH. Chen
H. Chen
JGJ. Goodacre
J. Goodacre
Based on a single time-point study of 34 healthy and 19 osteoarthritic knees in three different age groups (early, middle and late adulthood), this paper reports the potential of knee acoustic emission as a biomarker to monitor joint ageing and degeneration. Measurements were made of short transient high frequency acoustic emission signals generated by knee joints under stress during repeated sit-stand-sit movements along with joint angle. A statistically significant feature profile was established using a four-phase model of sit-stand-sit movements and two waveform features. The four-phase movement model is derived from joint angle measurement during repeated sit-stand-sit movements, and it consists of the ascending-acceleration and ascending-deceleration phases in the sit-to-stand movement, followed by the descending-acceleration and descending-deceleration phases in the stand-to-sit movement. The two statistically significant waveform features are extracted from AE measurement during repeated sit-stand-sit movements, and they consist of the peak magnitude value and average signal level of each AE burst. In addition to the use of bilateral plots, statistical distributions and 2D colour histograms to visualise the differences and similarities among participants, use of principal component analysis showed not only distinct data clusters corresponding to participating groups, but also an age- and disease-related trajectory progressing from the early adulthood healthy group to the late adulthood healthy group followed by the middle adulthood osteoarthritic group to the late adulthood osteoarthritic group. Furthermore, this trajectory shows increasing areas for each data cluster, with a highly compact cluster for the early adulthood healthy group at one end and a widely spread cluster for the late adulthood osteoarthritic group at the other end. From these results, a strong basis is formed for further development of knee acoustic emission as a convenient and non-invasive biomarker for quantitative assessment of joint ageing and degeneration.

27 July 2010 in The Open Medical Informatics Journal
Verified
Journal Article
Open access
LSLik-Kwan Shark
Lik-Kwan Shark
HCHongzhi Chen
Hongzhi Chen
JGJohn Goodacre
John Goodacre
By performing repeated sit-stand-sit movements to create stress on knee joints, short transient bursts of high frequency acoustic emission (AE) released by the knee joints were acquired from two age matched groups consisting of healthy and osteoarthritic (OA) knees, and significant differences between these two groups were discovered from the signal analysis performed. The analysis is based on a four-phase model of sit-stand-sit movements and a two-feature descriptor of AE bursts. The four phases are derived from joint angle measurement during movement, and they consist of the ascending-acceleration and ascending-deceleration phases in the sit-to-stand movement, followed by the descending-acceleration and descending-deceleration phases in the stand-to-sit movement. The two features are extracted from AE measurement during movement, and they consist of the peak magnitude value and average signal level of each AE burst. The proposed analysis method is shown to provide a high sensitivity for differentiation of the two age matched healthy and OA groups, with the most significant difference found to come from the peak magnitude value in the ascending-deceleration phase, clear quantity and strength differences in the image based visual display of their AE feature profiles due to substantially more AE bursts from OA knee joints with higher peak magnitude values and higher average signal levels, and two well separated clusters in the space formed by the principal components. These results provide ample support for further development of AE as a novel tool to facilitate dynamic integrity assessment of knee joints in clinic and home settings.

1 December 2014 in IET Biometrics
Verified
Journal Article
Open access
PDF file
YWYiding Wang
Yiding Wang
KZKe Zhang
Ke Zhang
LSLik‐Kwan Shark
Lik‐Kwan Shark
This paper presents a biometric identification system based on near‐infrared imaging of dorsal hand veins and matching of the keypoints that are extracted from the dorsal hand vein images by the scale‐invariant feature transform. The whole system is covered in detail, which includes the imaging device used, image processing methods proposed for geometric correction, region‐of‐interest extraction, image enhancement and vein pattern segmentation, as well as image classification by extraction and matching of keypoints. In addition to several constraints introduced to minimise incorrectly matched keypoints, a particular focus is placed on the use of multiple training images of each hand class to improve the recognition performance for a large database with more than 200 hand classes. By organising multiple keypoint sets extracted from multiple training images of each hand class into three sets, namely, the union, the intersection and the exclusion, based on their inter‐class and intra‐class relationships, this study shows the contribution made by each set to the recognition performance and demonstrates the feasibility of achieving 100% correct recognition by combining the three sets, based on the experiments conducted using more than 2000 dorsal hand vein images.

6 March 2025 in Expert Systems with Applications
Verified
Journal Article
Closed access
BLBocheng Liang
Bocheng Liang
HLHuiLan Luo
HuiLan Luo
JWJianqin Wang
Jianqin Wang
LSLik-Kwan Shark
Lik-Kwan Shark

23 January 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
XCXin Chen
Xin Chen
MVMartin R Varley
Martin R Varley
LSLik-Kwan Shark
Lik-Kwan Shark
GSGlyn S Shentall
Glyn S Shentall
MKMike C Kirby
Mike C Kirby
The paper presents a computationally efficient 3D-2D image registration algorithm for automatic pre-treatment validation in radiotherapy. The novel aspects of the algorithm include (a) a hybrid cost function based on partial digitally reconstructed radiographs (DRRs) generated along projected anatomical contours and a level set term for similarity measurement; and (b) a fast search method based on parabola fitting and sensitivity-based search order. Using CT and orthogonal x-ray images from a skull and a pelvis phantom, the proposed algorithm is compared with the conventional ray-casting full DRR based registration method. Not only is the algorithm shown to be computationally more efficient with registration time being reduced by a factor of 8, but also the algorithm is shown to offer 50% higher capture range allowing the initial patient displacement up to 15 mm (measured by mean target registration error). For the simulated data, high registration accuracy with average errors of 0.53 mm +/- 0.12 mm for translation and 0.61 +/- 0.29 degrees for rotation within the capture range has been achieved. For the tested phantom data, the algorithm has also shown to be robust without being affected by artificial markers in the image.

1 July 2010
Verified
Conference Paper
Closed access
YLYingzhu Li
Yingzhu Li
LSLik-Kwan Shark
Lik-Kwan Shark
Sarah Jane HobbsSarah Jane Hobbs
Sarah Jane Hobbs
JIJames Ingham
James Ingham
Presented in this paper is a novel real-time virtual reality game developed to enable two participants to play table tennis immersively with each other's avatar in a shared virtual environment. It uses a wireless hybrid inertial and ultrasonic tracking system to provide the positions and orientations of both the head (view point) and hand (racket) of each player, as well as two large rear-projection stereoscopic screens to provide a view-dependent 3D display of the game environment. Additionally, a physics-based ball animation model is designed for the game, which includes fast detection of the ball colliding with table, net and quick moving rackets. The system is shown to offer some unique features and form a good platform for development of other immersive games for multiple players.