Willis Chow

Willis Chow

Auto-generated profile, based on publicly available information

Willis Chow

Canadian Food Inspection Agency, Calgary Laboratory , 3650-36th St N.W , Calgary, AB T2L 2L1

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2020 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Open access
PDF file
JWJian Wang
Jian Wang
DLDaniel Leung
Daniel Leung
WCWillis Chow
Willis Chow
JWJon W Wong
Jon W Wong
JCJames Chang
James Chang
Effective and expansive methods for multiresidue pesticide analysis are desired for routine monitoring programs. These methods are complexed especially when several hundred pesticides are involved. Two approaches to sort data and identify isomers and isobaric ions in the pesticide mixture were evaluated to possibly determine whether they could be differentiated by mass resolving power and/or chromatographic resolution. This study presented an application of ultra-high performance liquid chromatography electrospray Q-Orbitrap mass spectrometry (UHPLC/ESI Q-Orbitrap) along with QuEChERS for quantitation of 655 pesticide residues in fruits and vegetables. From the developed method, 94.7% of the 655 pesticides in fruits or 93.9% in vegetables had recoveries between 81% and 110%; 98.3% in both fruits and vegetables had an intermediate precision ≤ 20%; and 97.7% in fruits or 97.4% in vegetables showed measurement uncertainty ≤ 50%. When the retention time difference (ΔtR) of two isomers were ≥ 0.12 min, they were chromatographically resolved. Twenty five out of 35 pairs or groups of isomers were chromatographically separated (ΔtR ≥ 0.12 min), but 14 pairs were not resolved (ΔtR < 0.12 min). There were 493 pairs of pesticides with a mass-to-charge (m/z) difference less than 1 Da. However, only one pair of isobaric ions could not be separated by mass and chromatographic resolution. UHPLC/ESI Q-Orbitrap along with QuEChERS sample preparation offered a practical quantitative companion method to an nDATA workflow for pesticide residue analysis in routine monitoring programs for food safety.


27 September 2021 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
WCWillis Chow
Willis Chow
DLDaniel Leung
Daniel Leung
JWJian Wang
Jian Wang
Background: Triple quadrupole (MS/MS) and high-resolution mass spectrometry (HRMS), coupled with ultra-high performance (UHP) liquid chromatography (LC) or gas chromatography (GC), are technologies used to analyze pesticide residues in fruits and vegetables. LC-MS/MS has been the gold standard for analysis of pesticides, offering reliable performance and sensitivity, while LC-HRMS is expanding in application to serve as another benchmark. Method development and testing scope expansion are constantly required with new generation mass spectrometers. Objective: This article discusses the development and validation of a quantitative and confirmatory method that can analyze over 400 pesticide residues using a state-of-the-art UHPLC/electrospray ionization (ESI)-MS/MS system. Methods: Homogenized fruit and vegetable samples were fortified with pesticides and were extracted using a modified quick, easy, cheap, effective, rugged, and safe method. Samples were injected onto a UHPLC/ESI-MS/MS system, and data were acquired in multiple reaction monitoring (MRM) mode. The method was validated using a nested experimental design, and was able to quantify and confirm 416 pesticides in fruits and vegetables. It was also complimentary to the UHPLC/ESI Q-Orbitrap quantitative and screening methods previously developed in the authors’ laboratory. Results: The method demonstrated good performance. In all matrixes, 92% of pesticides yielded recoveries between 81–110%, more than 95% of pesticides yielded intermediate precision ≤20%, about 65% of pesticides yielded measurement uncertainties ≤20%, and 96% of pesticides yielded measurement uncertainties ≤50%. Conclusion: This method shows great potential to be a standalone method or as part of a laboratory workflow for quantitative and confirmatory analysis of pesticide residues in fruits and vegetables. Highlights: This method was developed using the same mobile phases, analytical columns, and extraction procedure, as UHPLC/ESI Q-Orbitrap methods. Extracts can be run on either system, streamlining monitoring programs and offering high sample throughput.

28 January 2025 in Journal of Chromatography A
Verified
Journal Article
Open access
MKM․j․ Kelman
M․j․ Kelman
JRJustin B Renaud
Justin B Renaud
PMP․ McCarron
P․ McCarron
SHShawn J Hoogstra
Shawn J Hoogstra
WCW. Chow
W. Chow
MSMark W Sumarah
Mark W Sumarah
Monitoring for mycotoxins in food or feed matrices is necessary to ensure the safety and security of global food systems. Due to a lack of standardized methods and individual laboratory priorities, most institutions have developed their own methods for mycotoxin determinations. Given the diversity of mycotoxin chemical structures and physicochemical properties, searching databases, and comparing data between institutions is complicated. We previously introduced incorporating a retention index (RI) system into liquid chromatography mass spectrometry (LC-MS) based mycotoxin determinations. To validate this concept, we designed an interlaboratory study where each participating laboratory was sent N-alkylpyridinium-3-sulfonates (NAPS) RI standards, and 36 mycotoxin standards for analysis using their pre-optimized LC-MS methods. Data from 44 analytical methods were submitted from 24 laboratories representing various manufacturer platforms, LC columns, and mobile phase compositions. Mycotoxin retention times (tR) were converted to RI values based on their elution relative to the NAPS standards. Trichothecenes (deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyldeoxynivalenol) showed tR consistency (± 20-50 RI units, 1-5 % median RI) regardless of mobile phase or type of chromatography column in this study. For the remaining mycotoxins tested, the RI values were strongly impacted by the mobile phase composition and column chemistry. The ability to predict tR was evaluated based on the median RI mycotoxin values and the NAPS tR. These values were corrected using Tanimoto coefficients to investigate whether structurally similar compounds could be used as anchors to further improve accuracy. This study demonstrated the power of employing an RI system for mycotoxin determinations, further enhancing the confidence of identifications.

18 February 2025 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
JWJian Wang
Jian Wang
WCWillis Chow
Willis Chow
JWJon W Wong
Jon W Wong
Background: Cost-effective multi-residue pesticide methods with a broad detection scope are desired for risk-based monitoring programs. Objective: The aims were to evaluate the nDATA (non-target data acquisition for target analysis) workflow using ultra high performance liquid chromatography/electrospray ionization quadrupole-Orbitrap mass spectrometry (UHPLC/ESI quadrupole-Orbitrap (Q-Orbitrap)) and semi-quantitate 1094 pesticides in fruits and vegetables. Methods: Pesticide extracts from fresh produce were prepared using the Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) procedure. nDATA was carried out by utilizing UHPLC/ESI Q-Orbitrap full MS scan and variable data independent acquisition (UHPLC/ESI Q-Orbitrap full MS/vDIA MSMS). Data were processed using a compound database (CDB, 1094 pesticides) and one-point standard calibration with internal standards for semi-quantitation. Data processing criteria were based on Retention Time (±0.5 min) and mass accuracy of a Precursor ion (±5 ppm; RTP by full MS), or Retention Time (±0.5 min) and mass accuracy of a precursor ion (±5 ppm) and that of its Fragment Ion (±10 ppm; RTFI by full MS/vDIA). Results: RTP found 1010 and 1094 pesticides, while RTFI identified 906 and 1029 pesticides at 10 and 100 μg/kg, respectively. RTF detected all 30 LC-amenable pesticides and RTFI identified 29 of 30 LC-amenable pesticides in eight proficiency testing samples. There were 42 pairs of co-eluting isomeric pesticides and 5 pairs of isobaric pesticides that were not separated by mass resolving power and/or chromatographic separation (retention time difference ΔtR <0.12 min) with the current instrument parameter settings. Conclusion: The validated nDATA workflow using UHPLC/ESI Q-Orbitrap full MS/vDIA MSMS proved to be a comprehensive detection method for semi-quantitative screening of 1094 pesticides in fruits and vegetables. Highlights: nDATA combines both non-target data acquisition and target analysis. The non-target data acquisition generates data for retrospective analysis of a large number of pesticides (over 1000). The target analysis using a CDB and a one-point standard calibration affords confidence in semi-quantitative screening results.