Prashant P. Bansod

Prashant P. Bansod

Auto-generated profile, based on publicly available information

Prashant P. Bansod

Department of Biomedical Engineering, Shri G. S. Institute of Technology & Science, Indore 452003, India

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2013 in BioMed Research International
Verified
Journal Article
Open access
PDF file
VNVaishali Naik
Vaishali Naik
RGR. S. Gamad
R. S. Gamad
PBP. P. Bansod
P. P. Bansod
Background. The segmentation of the common carotid artery (CCA) wall is imperative for the determination of the intima-media thickness (IMT) on B-mode ultrasound (US) images. The IMT is considered an important indicator in the evaluation of the risk for the development of atherosclerosis. In this paper, authors have discussed the relevance of measurements in clinical practices and the challenges that one has to face while approaching the segmentation of carotid artery on ultrasound images. The paper presents an overall review of commonly used methods for the CCA segmentation and IMT measurement along with the different performance metrics that have been proposed and used for performance validation. Summary and future directions are given in the conclusion.

1 January 2018 in AEU - International Journal of Electronics and Communications
Verified
Journal Article
Closed access
ASAnurag Shrivastava
Anurag Shrivastava
PBPrashant Bansod
Prashant Bansod
KGKamlesh Gupta
Kamlesh Gupta
SMShabbir N. Merchant
Shabbir N. Merchant

16 March 2015 in Cogent Engineering
Verified
Journal Article
Open access
VTVibha Tiwari
Vibha Tiwari
PBP.P. Bansod
P.P. Bansod
AKAbhay Kumar
Abhay Kumar
Compressive sensing theory enables faithful reconstruction of signals, sparse in domain $ \Psi $, at sampling rate lesser than Nyquist criterion, while using sampling or sensing matrix $ \Phi $ which satisfies restricted isometric property. The role played by sensing matrix $ \Phi $ and sparsity matrix $ \Psi $ is vital in faithful reconstruction. If the sensing matrix is dense then it takes large storage space and leads to high computational cost. In this paper, effort is made to design sparse sensing matrix with least incurred computational cost while maintaining quality of reconstructed image. The design approach followed is based on sparse block circulant matrix (SBCM) with few modifications. The other used sparse sensing matrix consists of 15 ones in each column. The medical images used are acquired from US, MRI and CT modalities. The image quality measurement parameters are used to compare the performance of reconstructed medical images using various sensing matrices. It is observed that, since Gram matrix of dictionary matrix ($ \Phi \Psi \mathrm{)} $ is closed to identity matrix in case of proposed modified SBCM, therefore, it helps to reconstruct the medical images of very good quality

15 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VBVibha Bhatnagar
Vibha Bhatnagar
PBPrashant P. Bansod
Prashant P. Bansod
Purpose: Tongue image analysis for disease diagnosis is an ancient, traditional, non-invasive diagnostic technique widely used by traditional medicine practitioners. Deep learning-based multi-label disease detection models have tremendous potential for clinical decision support systems because they facilitate preliminary diagnosis. Methods: In this work, we propose a multi-label disease detection pipeline where observation and analysis of tongue images captured and received via smartphones assist in predicting the health status of an individual. Subjects, who consult collaborating physicians, voluntarily provide all images. Images thus acquired are first and foremost classified either into a diseased or a normal category by a 5-fold cross-validation algorithm using a convolutional neural network (MobileNetV2) model for binary classification. Once it predicts the diseased label, the disease prediction algorithm based on DenseNet-121 uses the image to diagnose single or multiple disease labels. Results: The MobileNetV2 architecture-based disease detection model achieved an average accuracy of 93% in distinguishing between diseased and normal, healthy tongues, whereas the multilabel disease classification model produced more than 90% accurate results for the disease class labels considered, strongly indicating a successful outcome with the smartphone-captured image dataset. Conclusion: AI-based image analysis shows promising results, and an extensive dataset could provide further improvements to this approach. Experimenting with smartphone images opens a great opportunity to provide preliminary health status to individuals at remote locations as well, prior to further treatment and diagnosis, using the concept of telemedicine.

1 November 2010
Verified
Conference Paper
Closed access
TJTripti Jain
Tripti Jain
PBPrashant Bansod
Prashant Bansod
CKC.B. Singh Kushwah
C.B. Singh Kushwah
MMMayenk Mewara
Mayenk Mewara
Median filter is a non-linear filter used in image processing for impulse noise removal during morphological operations, image enhancement and other image processing operations. It finds its typical application in the situations where edges are to be preserved for higher level operations like segmentation, object recognition etc. Real-time applications, such as video and high speed acquisition cameras often require fast algorithms for processing. Reconfigurable hardware filters can be embedded with image acquisition system to achieve this goal. In this paper we propose a hardware implementation of a median filter with programmable window sizes ranging from 3×3 to 7×7. This median filter was designed, simulated and synthesized on the Xilinx family of FPGAs (XC3S500E of Spartan-3E). The performance of the same was evaluated for variety of images. For 3×3 window size, the maximum operating frequency achieved was approximately 89 MHz and for 5×5 window sizes, the maximum operating frequency achieved was approximately 89 MHz. The VHDL was used to design the above 2-D median filter using ISE (Xilinx) tool. The proposed hardware implementation took on an average 0.00246 m sec. For a frame of size 4×4 (for window size 3×3), 0.22472 m sec on for a frame of size 16×16 (for window size 5×5) and 0.468 m sec on a average for a frame of size 16×16 (for window size 7×7). The algorithm proposed for the median filter is based on sorting pixel samples and extracting their median values.

1 October 2017
Verified
Conference Paper
Closed access
NSNitin Singh
Nitin Singh
PBP. P. Bansod
P. P. Bansod
This Paper proposes second order switched capacitor filters for ECG application. ECG signal contains different types of noise and artifacts thereby giving rise to the need for signal filtering. Thus a switched capacitor highpass filter withcutoff frequency 0.05Hz and a low pass filterwith cutoff frequency 150Hz are presented. The circuits consist of two phase clock generator, gain stage and switched capacitors. These circuits are designed in Cadence Virtuoso Analog Design Environment using SCL (semi-conductor laboratory) 180nm technology.