4 April 2024 in Journal of Power Sources
1 October 2021 in Applied Energy
17 December 2021 in IEEE Transactions on Power Systems
The quantification of heating, ventilation, and air condition (HVAC) system flexibility is critical to the operations of both the grid and buildings in demand response (DR) programs. However, the flexibility quantification is challenging due to the non-linearity and non-convexity of thermal dynamics associated with HVAC components. This paper proposes a novel HVAC flexibility quantification method based on a semidefinite programming (SDP) formulation. The SDP is reformulated from the non-convex problem of HVAC power optimization, and can be solved efficiently in real-time. The physics-based HVAC model is incorporated to ensure the reliability and accuracy of solutions. The quantification results are organized into an HVAC flexibility table that can provide response strategies on adjusting HVAC setpoints in response to the grid signals received. The developed response strategies minimize occupant discomfort while satisfying grid requirements. A case study of a test building model is carried out to illustrate the flexibility quantification framework and compares the performance of two DR strategies.
7 March 2022 in IEEE Transactions on Power Systems
Commercial buildings are great demand response resources in the energy and regulation markets. Many commercial building heating, ventilation and air conditioning (HVAC) systems are composed of a chiller producing chilled water, and multiple Air-Handling Units (AHUs) distributing cooled air to thermal zones. Demand response of such systems has the potential to closely track energy and regulation market signals. However, existing control methods are mostly focused on fan control, neglecting the impact of the air loop fan control on the power consumption of water loop pumps and chillers. This paper presents a complete modeling of a commercial building HVAC system consisting of chiller, water pump and multiple AHUs, and develops a two-level control to follow five-minute energy market signals and four-second frequency regulation signals. The first-level coarse control provides commands for both water and air loop variables, the second-level fine control adjusts the fan commands while maintaining the water loop inputs within the five-minute control period. As a result, the water-loop power serves as a basis to track energy market signals and the air-loop fan control can be adjusted flexibly for frequency regulation. A high-fidelity model in Dymola is built to validate the model and control. The validation is conducted through co-simulation between Matlab and Dymola model via the Building Controls Virtual Test Bed (BCVTB). The simulation results show significant tracking improvement with the proposed two-level control framework.
19 January 2024 in International Journal of Refrigeration
26 June 2024 in Journal of Cleaner Production