Takuya Okada

Takuya Okada

Auto-generated profile, based on publicly available information

Takuya Okada

Department of Clinical Engineering, Sapporo Heart Center Sapporo Cardiovascular Clinic Sapporo Japan

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012
Verified
Conference Paper
Closed access
TOTakuya Okada
Takuya Okada
SGShuoxin Gu
Shuoxin Gu
NXNan Xiao
Nan Xiao
QFQiang Fu
Qiang Fu
YYYasuhiro Yamauchi
Yasuhiro Yamauchi
In this paper, we discuss a multi-DOFs locomotion and position detection system of the microrobot to realize the wireless locomotion. Also we propose one wireless microrobot with two motions controlled by changing the outside magnetic field. When generating alternating magnetic field, the microrobot can be driven by the fin motion just like fish. When generating rotating magnetic field, the microrobot can move in the spiral jet motion. Based on the experimental results of the locomotion, we confirm that the microrobot can move in forward, backward, floating motion and turning motion. In addition, we have developed a position detection system of the microrobot. We use least square method to solve the inverse problem. To evaluate the error of the proposed position detection system, we will do experiment by using 6 magnetic field sensors and program. Base on this experiment, we also confirm that the proposed position detection system can detect the position of the microrobot within 50mm from sensor in vertical direction, and its average error is within 6.09mm.

1 November 2024 in EP Europace
Verified
Journal Article
Open access
RWRyuta Watanabe
Ryuta Watanabe
KNKoichi Nagashima
Koichi Nagashima
YSYasuhiro Shirai
Yasuhiro Shirai
TKTakayuki Kitai
Takayuki Kitai
TOTakuya Okada
Takuya Okada
YOYasuo Okumura
Yasuo Okumura
Aims: Catheter ablation (CA) of idiopathic ventricular arrhythmias (VAs) from the epicardial left ventricular summit is challenging. The endocardial approach targets two sites: the endocardial closest site (ECS) to the epicardial earliest activation site (epi-EAS) and the endocardial earliest activation site (endo-EAS). We aimed to differentiate between cases where CA at the ECS was effective and where CA at the endo-EAS yielded success. Methods and results: Fifty-eight patients (47 men; age 60 ± 13 years) were analysed with VAs in which the EAS was observed in the coronary venous system (CVS). Overall, VAs were successfully eliminated in 42 (72%) patients: 8 in the CVS, 8 where the ECS matched with the endo-EAS, 11 at the ECS, and 15 at the endo-EAS. A successful ECS ablation was associated with a shorter epi-EAS–ECS distance (10.2 ± 4.7 vs. 18.8 ± 5.3 mm; P < 0.001) and shorter epi-EAS–left main coronary trunk (LMT) ostial distance (20.3 ± 7.6 vs. 30.3 ± 8.4 mm; P = 0.005), with optimal cut-off values of ≤12.6 and ≤24.0 mm, respectively. A successful endo-EAS ablation was associated with an earlier electrogram at the endo-EAS [23 (8, 36) vs. 15 (0, 19) ms preceding the QRS; P < 0.001] and shorter epi-EAS–endo-EAS interval [6 (1, 8) vs. 22 (12, 25) ms; P < 0.001], with optimal cut-off values of ≥18 and ≤9 ms, respectively. Conclusion: Shorter anatomical distances between the epi-EAS and ECS, and between the epi-EAS and LMT ostium, predict a successful ECS ablation. The prematurity of the endo-EAS electrogram and a shorter interval between the epi-EAS and endo-EAS predicted a successful endo-EAS ablation.

2 July 2023 in Journal of Arrhythmia
Verified
Journal Article
Open access
TOTakuya Okada
Takuya Okada
JMJunji Morita
Junji Morita
YKYuhei Kasai
Yuhei Kasai
TKTakayuki Kitai
Takayuki Kitai
TFTsutomu Fujita
Tsutomu Fujita

22 August 2023 in Journal of Arrhythmia
Verified
Journal Article
Open access
TOTakuya Okada
Takuya Okada
JMJunji Morita
Junji Morita
TKTakayuki Kitai
Takayuki Kitai
TFTsutomu Fujita
Tsutomu Fujita
YKYusuke Kondo
Yusuke Kondo
In this study, we report two cases with oversensing due to air accumulation in the subcutaneous implantable cardioverter‐defibrillator (S‐ICD) device generator header. If trapped air in the header of the device is suspected, the re‐connection procedure should be considered or the primary vector must be used, which might prevent oversensing.