Keiji Enpuku

Keiji Enpuku

Auto-generated profile, based on publicly available information

Keiji Enpuku

Department of Electrical and Electronic Engineering, Kyushu University , Fukuoka 819-0395, Japan

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2016 in Superconductor Science and Technology
Verified
Journal Article
Open access
PDF file
RKRainer Körber
Rainer Körber
JSJan-Hendrik Storm
Jan-Hendrik Storm
HSHugh Seton
Hugh Seton
JMJyrki P Mäkelä
Jyrki P Mäkelä
RPRitva Paetau
Ritva Paetau
JNJukka Nenonen
Jukka Nenonen

17 March 2017 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
KEKeiji Enpuku
Keiji Enpuku
YTYuya Tsujita
Yuya Tsujita
KNKota Nakamura
Kota Nakamura
TSTeruyoshi Sasayama
Teruyoshi Sasayama
TYTakashi Yoshida
Takashi Yoshida
Magnetic biosensing techniques that are based on the use of bio-functionalized magnetic nanoparticles (magnetic markers) and superconducting quantum interference devices (SQUIDs) are expected to have various advantages when compared with conventional biosensing methods. In this paper, we review the recent progress made in magnetic biosensing techniques. First, we describe the most important parameters of magnetic markers that are intended for use in biosensing, i.e., the magnetic signal and the relaxation time that are determined by the Brownian and/or Néel relaxation mechanisms. We note that these parameters are significantly dependent on the marker size, and as a result, commercial markers exhibit a wide variety of values for these key parameters. Next, we describe three measurement methods that have been developed based on the magnetic properties of these markers, i.e., AC susceptibility, relaxation and remanence-based measurement methods. The weak (picotesla-range) signals emitted by the markers can be measured precisely with a SQUID system using these methods. Finally, we give examples of biosensing for in vitro and in vivo medical diagnosis applications. For in vitro diagnosis, high-sensitivity detection of various biological targets has been demonstrated without use of any washing process to separate the bound and free markers. For in vivo applications, detection of the quantities and the three-dimensional positions of the markers that have been injected into the test subject are demonstrated. These results confirm the effectiveness of magnetic biosensing techniques.

1 September 2007 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
KEK. Enpuku
K. Enpuku
TTT. Tanaka
T. Tanaka
TMT. Matsuda
T. Matsuda
FDF. Dang
F. Dang
NEN. Enomoto
N. Enomoto
MSM. Schilling
M. Schilling
Properties of magnetic nanoparticles in the Brownian relaxation region were studied. Using the magnetic nanoparticles that exhibit remanence, we measured the magnetic properties, such as static magnetization, magnetic relaxation, and alternating current susceptibility, in a solution. Comprehensive comparisons were made between the experimental results and the theoretical ones predicted from the Brownian relaxation. From the comparison, the distributions of the particle parameters, i.e., the magnetic moment and the relaxation time, were estimated. It was shown that all the magnetic properties can be well explained when we take into account the parameter distributions in the sample.

1 September 2006 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
KEK. Enpuku
K. Enpuku
KSK. Soejima
K. Soejima
TNT. Nishimoto
T. Nishimoto
HTH. Tokumitsu
H. Tokumitsu
HKH. Kuma
H. Kuma
KYK. Yoshinaga
K. Yoshinaga
We have developed a liquid phase immunoassay system utilizing a magnetic marker and a superconducting quantum interference device (SQUID). In this system, the magnetic marker was used to detect the biological material called antigen. The magnetic marker was designed so as to generate a remanence, and the remanence field of the markers that bound to the antigens was measured with the SQUID. The measurement was performed in a solution that contained both the bound and free (or unbound) markers, i.e., without using the so-called bound/free (BF) separation process. The Brownian rotation of the free markers in the solution was used to distinguish the bound markers from the free ones. Using the system, we conducted the detection of biological material called IgE without BF separation. At present, we could detect the IgE down to 7pg (or 39amol ).

20 February 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
WYWataru Yoshimura
Wataru Yoshimura
TSTeruyoshi Sasayama
Teruyoshi Sasayama
KEKeiji Enpuku
Keiji Enpuku
Defect detection on the backside of thick steel plates is essential for the safety maintenance of most infrastructures in which they are used. Eddy-current testing (ECT) is a promising method to detect the defects in a steel plate, and inspections at low frequencies are necessary to suppress the skin effect. However, if the frequency is reduced further, the signal from the detection coil also becomes smaller. Therefore, we assessed the optimal frequency for the detection of slit defects on the backside of a 10 mm thick steel plate based on experiments and electromagnetic simulations using the finite-element method. The results suggest that the optimal frequency to detect the defects is approximately 8-10 Hz when the height of the slit exceeds 6 mm. Similarly, in the simulation, the signal was maximized when the frequency was 8-10 Hz, which validates the experimental results. Furthermore, we propose a method to emphasize the deeper defects using multi-frequency data as a fundamental study. The results show that the backside defects are depicted more clearly.

3 April 2020 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
KEKeiji Enpuku
Keiji Enpuku
AEAhmed L. Elrefai
Ahmed L. Elrefai
TYTakashi Yoshida
Takashi Yoshida
TKTamara Kahmann
Tamara Kahmann
JZJing Zhong
Jing Zhong
FLFrank Ludwig
Frank Ludwig
We estimated the effective magnetic anisotropy constant K of magnetic nanoparticles (MNPs) from the temperature dependence of the coercive field Hc of the M–H curve for use in biosensing applications. For this purpose, a previous analytical expression for Hc was extended so that it can be applied to nanoparticles with a size distribution. Using the extended expression for Hc, we estimated the K value of multi-core based MNP sample that consists of crystalline aggregates of elementary particles. We prepared three MNP samples. One is Resovist, in which elementary particles and aggregates are mixed. The Resovist sample was magnetically divided into two fractions called MS1 and MS3, which included mainly aggregates and elementary particles, respectively. We discuss the K value of elementary particles and aggregates from the comparison among the three samples. It is suggested that the K value of the aggregates is much smaller than that of the elementary particles. The temperature dependence of K of the aggregates is also discussed.