Kristen J. Margevicius

Kristen J. Margevicius

Auto-generated profile, based on publicly available information

Kristen J. Margevicius

Defense Systems and Analysis Division, Los Alamos National Laboratory, Los Alamos, New Mexico, United States of America

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 1998 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
LCLutz E. Claes
Lutz E. Claes
CHChrista A. Heigele
Christa A. Heigele
CNCornelia Neidlinger-Wilke
Cornelia Neidlinger-Wilke
DKDaniela Kaspar
Daniela Kaspar
WSWalter Seidl
Walter Seidl
PAPeter Augat
Peter Augat
An interdisciplinary study based on animal experiments, cell culture studies, and finite element models is presented. In a sheep model, the influence of the osteotomy gap size and interfragmentary motion on the healing success was investigated. Increasing gap sizes delayed the healing process. Increasing movement stimulated callus formation but not tissue quality. Typical distributions of intramembranous bone, endochondral ossification, and connective tissue in the fracture gap are quantified. The comparison of the mechanical data determined by a finite element model with the histologic images allowed the attribution of certain mechanical conditions to the type of tissue differentiation. Intramembranous bone formation was found for strains smaller than approximately 5% and small hydrostatic pressure (4%) turned away from the principal strain axis and avoided larger deformations. It is hypothesized that gap size and the amount of strain and hydrostatic pressure along the calcified surface in the fracture gap are the fundamental mechanical factors involved in bone healing.

1 November 1994 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
KMKristen Margevicius
Kristen Margevicius
TBThomas Bauer
Thomas Bauer
JMJames McMahon
James McMahon
SBS A Brown
S A Brown
KMKatherine. Merritt
Katherine. Merritt
Particles of wear debris have been implicated in osteolysis around and aseptic loosening of total joint prostheses, but the number and size distribution of particles present in periprosthetic tissues are unknown. A method of particle assay was developed, consisting of nitric-acid digestion o

1 July 1998 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
PAPeter Augat
Peter Augat
KMKristen Margevicius
Kristen Margevicius
JSJörg Simon
Jörg Simon
SWSteffen Wolf
Steffen Wolf
GSGebhard Suger
Gebhard Suger
LCLutz Claes
Lutz Claes

1 July 1996 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PAPeter Augat
Peter Augat
JMJosef Merk
Josef Merk
AIAnita Ignatius
Anita Ignatius
KMKristen Margevicius
Kristen Margevicius
GBGerhard Bauer
Gerhard Bauer
LCLutz Claes
Lutz Claes
Secondary fracture healing is known to be accelerated by the process of periosteal callus formation that can be induced by flexible fracture fixation in connection with loading of the injured extremity. The purpose of this study was to compare the healing of experimental fractures of long bones in sheep under early weightbearing with that of fractures under delayed, steadily increasing weightbearing. Differences in the quality of fracture healing were described by biomechanical (rigidity of fracture, indentation stiffness of callus) and histologic methods. Prevention from early, full weightbearing resulted in a higher flexural rigidity of the fracture, an increased mechanical stiffness of the callus tissue, and an enhanced bone formation at the healing front. Although early loading of a fresh fracture initiated an enormous amount of periosteal callus, the healing of the osteotomy was significantly delayed, and the quality of the newly formed tissue was reduced as compared with fractures with a reduced loading situation. A reduction of load transfer by delaying full weightbearing is advantageous for the healing of fractures stabilized with flexible fixation systems.

2 January 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KMKristen J. Margevicius
Kristen J. Margevicius
NGNicholas Generous
Nicholas Generous
KTKirsten J. Taylor-McCabe
Kirsten J. Taylor-McCabe
MBMac Brown
Mac Brown
WDW. Brent Daniel
W. Brent Daniel
ADAlina Deshpande
Alina Deshpande
In recent years, biosurveillance has become the buzzword under which a diverse set of ideas and activities regarding detecting and mitigating biological threats are incorporated depending on context and perspective. Increasingly, biosurveillance practice has become global and interdisciplinary, requiring information and resources across public health, One Health, and biothreat domains. Even within the scope of infectious disease surveillance, multiple systems, data sources, and tools are used with varying and often unknown effectiveness. Evaluating the impact and utility of state-of-the-art biosurveillance is, in part, confounded by the complexity of the systems and the information derived from them. We present a novel approach conceptualizing biosurveillance from the perspective of the fundamental data streams that have been or could be used for biosurveillance and to systematically structure a framework that can be universally applicable for use in evaluating and understanding a wide range of biosurveillance activities. Moreover, the Biosurveillance Data Stream Framework and associated definitions are proposed as a starting point to facilitate the development of a standardized lexicon for biosurveillance and characterization of currently used and newly emerging data streams. Criteria for building the data stream framework were developed from an examination of the literature, analysis of information on operational infectious disease biosurveillance systems, and consultation with experts in the area of biosurveillance. To demonstrate utility, the framework and definitions were used as the basis for a schema of a relational database for biosurveillance resources and in the development and use of a decision support tool for data stream evaluation.

1 July 1996 in Journal of Biomedical Materials Research
Verified
Journal Article
Closed access
PDF file
KMK. J. Margevicius
K. J. Margevicius
LCL. E. Claes
L. E. Claes
LDL. Dürselen
L. Dürselen
KHK. Hanselmann
K. Hanselmann