17 November 2023 in IEEE Transactions on Power Electronics
During asymmetric faults, the coupling between positive and negative (PN) sequences significantly affects the phase-locked-loop (PLL) synchronization transient stability (PSTS) of a weak-grid connected voltage source converter (WG-VSC). However, little literature is on analyzing the PSTS while considering PN sequence coupling. This article has analyzed the PSTS of the WG-VSC system considering PN sequence coupling under asymmetric faults for the first time. First, the Takagi–Sugeno method is adopted to construct the largest estimated domain of attraction (LEDA) at an equilibrium point of the system during asymmetric faults. This LEDA enables quantitative analysis of PLL synchronization transient instability phenomena. Furthermore, from the point of view of ensuring the PSTS, the feasible region of PN currents (FR-PNC) of the system during asymmetric faults has been obtained. In addition, an algorithm is proposed to visualize this 4-D FR-PNC in 2-D space. Finally, the theoretical analysis is validated by time domain experiments conducted on the RT-Box hardware-in-the-loop experimental platform.
2 May 2025 in IEEE Transactions on Power Electronics
During fault recovery stage, multiparallel grid-forming (MP-GFM) converters may retrigger the current limiter, leading to transient synchronization instability. While most existing studies focus on the transient synchronization stability (TSS) of single converters, and the well-established TSS studies designed for synchronous generators are not directly applicable to MP-GFM converters due to two key differences: active and reactive power control loop (ARPCL) coupling and current limiting. This article aims to address the TSS issue of MP-GFM converters during fault recovery stage, considering these two factors. First, a mathematical model of a system with MP-GFM converters is developed, considering ARPCL coupling and current limiting. Then, for the first time, the current limiting constrained largest estimated domain of attraction (CL-LEDA) is defined and constructed. Specifically, unlike traditional energy function (EF) that only considers active power control dynamics, an analytical EF that incorporates ARPCL coupling is proposed in this article. Furthermore, considering current limiting constraint, a new idea to calculate the critical energy value is proposed based on LaSalle's invariance principle. Then, the CL-LEDA can be constructed by the obtained EF and critical energy value. Provided that the operating state is located within this CL-LEDA at fault clearance moment, all MP-GFM converters will achieve transient stability, without triggering current limiting during faults recovery stage. Finally, experimental results based on RT-LAB hardware-in-the-loop and complete hardware-based experimental verify the analysis.
19 August 2024 in IEEE Transactions on Power Electronics
This article investigates the phase-locked loop (PLL) synchronization transient stability (PLL-STS) issue of grid-tied multiple voltage source converters (MVSCs) systems, specifically focusing on transient stability evaluation and transient interaction analysis. First, a novel PLL-STS assessment method for MVSCs systems has been proposed, which considers angular frequency jumps, nonlinear damping, and transient interactions among VSCs. Compared with previous studies, this method can accurately evaluate PLL-STS of MVSCs system since the acceleration and deceleration areas of VSCs can be accurately determined by combining equal-area criterion and numerical integration method. Moreover, it can identify the dominant converters which lead to transient instability. Second, by introducing static and dynamic interaction coefficients, influence of static and dynamic interaction on the transient stability of individual converters is quantitatively analyzed. Finally, the theoretical analysis results are verified by PSCAD/ EMTDC time-domain simulation results and RT-LAB hardware-in-the-loop experimental results.
29 October 2024 in IEEE Transactions on Industrial Electronics
Large power fluctuation may cause transient instability in renewable power generations (RPGs) via voltage source converter based high voltage direct current transmission (VSC-HVDC) system. First, this article establishes a reduced-order model of a system including grid-following RPGs and grid-forming VSC-HVDC, derives equivalent motion equations, and analyzes the dynamic coupling mechanism among different types of control units and their impacts on the system's transient stability. Then, a transient stability assessment method based on equivalent acceleration and deceleration areas is proposed. Furthermore, the power feasible region of such a system is constructed, and the influence of main circuit and control parameters on system stability is analyzed. Finally, the effectiveness of the proposed transient stability analysis method is validated through experimental results conducted on the real-time laboratory (RT-LAB) platform.
16 October 2024 in IEEE Transactions on Sustainable Energy
During grid faults, the grid-connected paralleled converter systems is susceptible to a phase-locked loop (PLL) synchronization transient instability. Most existing studies focus on first-swing transient stability analysis using the equal-area criterion. However, achieving first-swing transient stability does not guarantee overall stability, as the system may still experience multi-swing transient instability. This paper analyzes the type of multi-swing transient instability issue from two aspects: transient instability mechanism and transient stability assessment. Firstly, the mechanism of multi-swing transient instability is revealed from the transient energy conversion point of view. Then, considering transient interactions between converters, the largest estimated domain of attraction (LEDA) is constructed utilizing the Takagi-Sugeno method. Using the LEDA, the multi-swing transient instability problem of the grid-connected paralleled converter systems is quantitatively analyzed. Finally, the theoretical results are verified based on the RT-LAB hardware-in-the-loop experimental platform.
24 September 2022 in IET Power Electronics
When the traditional two‐stage boost inverter is used in photovoltaic (PV) and energy storage systems, it is necessary to connect additional bidirectional conversion devices, which will increase the loss of the system and increase the complexity of system control. Therefore, an improved energy storage switched boost (ESSB) grid‐connected inverter is proposed in this paper. The system has the advantages of high integration, high gain and dead time immunity. By controlling the duty cycle of the system, the energy management of the battery can be realized. The system consists of three parts: PV cells, ESSB network and grid‐connected inverter. In order to maximize the energy utilization, this paper uses the disturbance observation method to track the maximum power point of PV cells, and formulates a set of energy management strategy to control the energy flow between the three energy units. Simulation and experiments verify the superiority of the topology and the feasibility of the energy storage strategy.