25 May 2021 in IEEE Transactions on Power Delivery
This paper addresses lightning surges on the transmission systems with a new hybrid method, using a 1D FDTD model for the transmission line and a PEEC model for the tower and lightning channel. Compared with other circuit-based models, mutual coupling between the lightning channel and other parts in the system can be fully considered. This hybrid method has been validated numerically and experimentally, and good agreements are observed. This method then is applied to analyze the lightning surges on a 500 kV double-circuit transmission line system. It is found that the lightning channel has a significant impact on the surge response of the tower struck. Ignoring the coupling from the channel to the tower will weaken the hazard of lightning strikes. However, the influence of its coupling to the transmission line is not critical. The choice of interfacing points between these two models is then suggested. Furthermore, the influence of the tower footing is inves tigated. It is found that the insulator voltage is made of inductive and resistive components. The inductive component becomes dominant in the case of high soil conductivity and low grounding resistance. The voltage generally increases with decreasing soil conductivity and tends to decay slowly with time.
8 September 2021 in IEEE Transactions on Power Delivery
This paper presents an assessment of lightning protection schemes for overhead lines from two aspects: protection performance and economic cost. Considering the random nature of lightning, the Monte-Carlo method with a heuristic technique is applied in the assessment. The one-dimensional finite-difference time-domain method is adopted to evaluate lightning overvoltages on insulators and lightning currents in surge arresters for failure assessment. The failure rate of an overhead line is addressed under both direct lightning and indirect lightning. A reduced set of design parameters are identified. It is found that the line insulation itself with a critical flashover overvoltage of less than 200 kV is not sufficient for lightning protection, especially against direct strokes. With other protection options, however, increasing the insulation level can greatly improve the protection performance. Installing surge arresters on every pole results in the best protection performance, but could be extremely expensive due to the replacement of failed surge arresters. The shielding wire provides moderate protection performance with a relatively low cost. The combination of the shielding wire and surge arresters provides much better performance under a wide range of soil conductivity with a moderate cost. It is worth mentioning that adopting high insulation strength for overhead lines in the new-line design could lead to significant cost savings for lightning protection. Guidelines for selecting design parameter values and protection schemes are provided, as well as a procedure for performance-cost evaluation.
27 January 2021 in IEEE Transactions on Electromagnetic Compatibility
This article discusses the lightning protection performance of a grounding grid for photovoltaic (PV) systems protected by independent lightning rods. Several grounding grid configurations are investigated, and the transferred voltages between the dc cables and supporting structures at different points in the PV system are evaluated using the finite difference time domain (FDTD) method. In the PV system without a dedicated grounding grid for supporting structures, the transferred voltage is very high, and is even worse if the soil resistivity is high. Installing a dedicated grounding grid, which is very costly in a large PV power plant, can reduce the amplitude of the transferred voltage and eliminate the residual voltage effectively. It is found that the arrangement using a bonding network is superior to other grounding improvement approaches in lightning protection. More importantly, the proposed approach is simple to implement and cost-effective. With the bonding network, the soil with high soil resistivity will not lead to severe overvoltage in the system. It is highly recommended to be adopted in the PV power plant protected by independent lightning rods.
15 May 2018 in IEEE Transactions on Power Delivery
This paper proposes an FDTD thin wire model, for modeling lossy wire structures with non-circular cross section in transient analysis. Unique correction factors of field quantities and surface electric field of wire structures are introduced in the model. These parameters are both frequency-dependent and position-variant. They are evaluated in an initialization process and are applied in the updating process using an iterative convolution technique. The proposed method is validated with the transmission line theory analytically and the traditional FDTD method numerically. Three types of wire structures are tested, including rectangular, H-shape and cross-shape structures. Good agreements are observed. It is found that the computation time is reduced to 1% of that with the conventional FDTD method, and the computer memory to 30% in the tested case. General guidelines on wire zone meshing are provided as well. Finally, this method is applied to analyze lightning surges in a light rail system under a direct lightning stroke.
28 October 2020 in IEEE Transactions on Electromagnetic Compatibility
This article presents a theoretical time-domain analysis of lightning surge propagation on a multistage and multi-conductor tower. An extended traveling wave theory using electric scalar potential is introduced. The non-TEM wave propagation in the tower is characterized by time/position-variant transient impedance. The analytical formulas of the transient impedance are presented for any position/time in the tower, as well as those of the reflection coefficient at a discontinuity. The concept of primary and secondary waves is introduced to depict the multiple reflections in the tower. It is found that the primary current wave attenuates during its propagation in the tower, and is corrected by a factor when crossing over the discontinuity. A pair of secondary waves is generated at the discontinuity, similar to a center-fed dipole. The proposed method is applied to evaluate the lightning current in a two-stage tower. The result of the proposed method is of high consistency with the FDTD result. It is also observed that the secondary waves could be neglected if the reflection coefficient is small. The traditional transmission line theory could lead to a significant error of the current in the tower.
26 November 2020 in IEEE Transactions on Electromagnetic Compatibility
In this article, a thin-wire model of single-core coaxial cables with three or more conductive layers is proposed for transient analysis using the finite-difference time-domain (FDTD) method. The multilayer cable is regarded as a series of 2-conductor coaxial transmission lines. The currents in these lines can be, however, unbalanced, and may not return via earth, such as in the case of a direct lightning strike. The FDTD method is employed to evaluate electromagnetic coupling outside the cable. Frequency-dependent surface impedances of conductors are fully considered using the Bessel functions. They are integrated into the time-domain analysis with a vector fitting technique. Updating equations for both lossless and lossy cables are derived. The proposed model is validated transmission line theory analytically and with the traditional FDTD method numerically. Good agreements are observed. Finally, the proposed model is applied to analyze the transients in a cable connection station under a direct lightning strike.