Denis M. Chernyshev

Denis M. Chernyshev

Auto-generated profile, based on publicly available information

Denis M. Chernyshev

National Research Nuclear University MEPhI, Kashirskoye Shosse 31, Moscow 115409, Russia

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2013 in Analytical Chemistry
Verified
Journal Article
Closed access
ASAlexey A. Sysoev
Alexey A. Sysoev
DCDenis M Chernyshev
Denis M Chernyshev
SPSergey S Poteshin
Sergey S Poteshin
AKAlexander V Karpov
Alexander V Karpov
OFOleg I Fomin
Oleg I Fomin
ASAlexander A Sysoev
Alexander A Sysoev

1 April 2014 in European Journal of Mass Spectrometry
Verified
Journal Article
Closed access
SPSergey S. Poteshin
Sergey S. Poteshin
DCDenis M. Chernyshev
Denis M. Chernyshev
AKAlexander V. Karpov
Alexander V. Karpov
YTYuriy B. Tuzkov
Yuriy B. Tuzkov
VKVyacheslav V. Kyzmin
Vyacheslav V. Kyzmin
ASAlexey A. Sysoev
Alexey A. Sysoev
Characteristic ion mobility mass spectrometry data, reduced mobility, and limits of detection (signal-to-noise ratio = 3) were determined for six synthetic drugs and cocaine by ion mobility time-of-flight mass spectrometry (IM-TOF-MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). The studied synthetic illicit drugs recently appeared on the recreational drug market as designer drugs and were methylone, 4-MEC (4′-methylethcathinone), 3,4-MDPV (3,4-methylenedioxypyrovalerone), JWH-210 [4-ethylnaphthalen-1-yl-(1-pentylindol-3-yl)methanone], JWH-250 [2-(2-methoxyphenyl)-1-(1-pentyl-1H-indol-3-yl)ethanone], and JWH-203 [1-pentyl-3-(2′-chlorophenylacetyl) indole]. Absolute reduced mobilities in nitrogen were 1.35, 1.28, 1.41, 1.30, 1.18, 0.98, 1.09, and 1.07 cm2 V−1 s−1, for methylone [M–H]+, methylone [M+H]+, 4-MEC [M–H]+, 4-MEC [M+H]+, 3,4-MDPV [M+H]+, JWH-210 [M+H]+, JWH-250 [M+H]+, and JWH-203 [M+H]+, respectively. Selected illicit drugs are easily identified by IM-TOF-MS during a 100 s analysis. Relative limits of detection ranged from 4 to 400 nM are demonstrated for these compounds. Such relative limits of detection correspond to 14 pg to 2 ng absolute limits of detection. Better detection limits are obtained in APCI mode for all the illicit drugs except cocaine. ESI mode was found to be preferable for the IM-TOF-MS detection of cocaine at trace levels. A single sample analysis is completed in an order of magnitude less time than that for conventional liquid chromatography/mass spectrometry approach. The application allows one to consider IM-TOF-MS as a good candidate for a method to determine quickly the recently surfaced designer drugs marketed on the internet as “bath salts,” “spice,” and “herbal blends”.

1 January 2015 in Physics Procedia
Verified
Journal Article
Open access
AKA.V. Karpov
A.V. Karpov
ASAlexey A. Sysoev
Alexey A. Sysoev
SPS.S. Poteshin
S.S. Poteshin
DCD.M. Chernyshev
D.M. Chernyshev
ASAlexey A. Sysoev
Alexey A. Sysoev
This article describes a genetic algorithm capable of fast search for optimum parameters of ion-optical systems with various types of reflective mirrors. Such an algorithm is an effective tool for solving optimization problems in ion and electron optics, where the use of analytical methods and direct programming becomes ineffective or impossible, and the stochastic search of variants consuming and costly. Genetic algorithm is an effective addition to standard developer tools and software environments such as SIMION-8-3D.


27 November 2011 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
DCD. M. Chernyshev
D. M. Chernyshev
IFI. S. Frolov
I. S. Frolov
AFA. S. Frolov
A. S. Frolov
MMM. S. Mukhanov
M. S. Mukhanov
ASAlexey A. Sysoev
Alexey A. Sysoev
An atmosphere pressure ion mobility spectrometer is described. Both electrospray and corona discharge ion sources were used. Increased up to 100 resolving power allows obtaining higher selectivity...

1 December 2016 in European Journal of Mass Spectrometry
Verified
Journal Article
Closed access
ASAlexey A. Sysoev
Alexey A. Sysoev
SPSergey S Poteshin
Sergey S Poteshin
DCDenis M Chernyshev
Denis M Chernyshev
ASAlexander A Sysoev
Alexander A Sysoev
An ion mobility time-of-flight mass spectrometry (IM-TOFMS)-based method has been preliminarily investigated for the identification of triphenylmethane ballpoint pen dyes on paper. The dyes were sampled from one-year-old ballpoint pen ink entries. The entries were written on paper documents stored in the dark in a bookcase. Sample solutions were prepared by extraction of dyes in a vial. Basic violet 2, Methyl violet 6B, Methyl violet 2B and Crystal violet were characterized by IM-TOFMS. Since the ballpoint ink dyes contain ionic compounds, the studied compounds were expected to form stable peaks in the atmospheric pressure drift tube ion mobility spectrometry, and this was experimentally verified. The studied dyes produce [M – Cl]+ ions in electrospray and form stable individual mass-selective reduced mobility peaks. The values of the characteristic reduced mobility are: 1.187 cm2/(V·s) for Basic violet 2 ( m/ z 330.20), 1.165 cm2/(V·s) for Methyl violet 6B ( m/ z 344.21), 1.156 cm2/(V·s) for Methyl violet 2B ( m/ z 358.23), 1.123 cm2/(V·s) for Crystal violet ( m/ z 372.24). IM-TOFMS is expected to be a promising tool for fast and reliable analysis of dyes in complex matrixes.