Emmanuelle Mouton-Barbosa

Emmanuelle Mouton-Barbosa

Auto-generated profile, based on publicly available information

Emmanuelle Mouton-Barbosa

Institut de Pharmacologie et de Biologie Structurale (IPBS), Université de Toulouse, CNRS, Université Toulouse III—Paul Sabatier (UPS) 1 , Toulouse, France

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2020 in Bioinformatics
Verified
Journal Article
Open access
DBDavid Bouyssié
David Bouyssié
AHAnne-Marie Hesse
Anne-Marie Hesse
EMEmmanuelle Mouton-Barbosa
Emmanuelle Mouton-Barbosa
MRMagali Rompais
Magali Rompais
CMCharlotte Macron
Charlotte Macron
CBChristophe Bruley
Christophe Bruley
Motivation: The proteomics field requires the production and publication of reliable mass spectrometry-based identification and quantification results. Although many tools or algorithms exist, very few consider the importance of combining, in a unique software environment, efficient processing algorithms and a data management system to process and curate hundreds of datasets associated with a single proteomics study. Results: Here, we present Proline, a robust software suite for analysis of MS-based proteomics data, which collects, processes and allows visualization and publication of proteomics datasets. We illustrate its ease of use for various steps in the validation and quantification workflow, its data curation capabilities and its computational efficiency. The DDA label-free quantification workflow efficiency was assessed by comparing results obtained with Proline to those obtained with a widely used software using a spiked-in sample. This assessment demonstrated Proline’s ability to provide high quantification accuracy in a user-friendly interface for datasets of any size. Availability and implementation: Proline is available for Windows and Linux under CECILL open-source license. It can be deployed in client–server mode or in standalone mode at http://proline.profiproteomics.fr/#downloads. Supplementary information: Supplementary data are available at Bioinformatics online.

1 May 2010 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
EMEmmanuelle Mouton-Barbosa
Emmanuelle Mouton-Barbosa
FRFlorence Roux-Dalvai
Florence Roux-Dalvai
DBDavid Bouyssié
David Bouyssié
FBFrançois Berger
François Berger
ESEric Schmidt
Eric Schmidt
APAnne Gonzalez de Peredo
Anne Gonzalez de Peredo
Cerebrospinal fluid (CSF) is the biological fluid in closest contact with the brain and thus contains proteins of neural cell origin. Hence, CSF is a biochemical window into the brain and is particularly attractive for the search for biomarkers of neurological diseases. However, as in the case of other biological fluids, one of the main analytical challenges in proteomic characterization of the CSF is the very wide concentration range of proteins, largely exceeding the dynamic range of current analytical approaches. Here, we used the combinatorial peptide ligand library technology (ProteoMiner) to reduce the dynamic range of protein concentration in CSF and unmask previously undetected proteins by nano-LC-MS/MS analysis on an LTQ-Orbitrap mass spectrometer. This method was first applied on a large pool of CSF from different sources with the aim to better characterize the protein content of this fluid, especially for the low abundance components. We were able to identify 1212 proteins in CSF, and among these, 745 were only detected after peptide library treatment. However, additional difficulties for clinical studies of CSF are the low protein concentration of this fluid and the low volumes typically obtained after lumbar puncture, precluding the conventional use of ProteoMiner with large volume columns for treatment of patient samples. The method has thus been optimized to be compatible with low volume samples. We could show that the treatment is still efficient with this miniaturized protocol and that the dynamic range of protein concentration is actually reduced even with small amounts of beads, leading to an increase of more than 100% of the number of identified proteins in one LC-MS/MS run. Moreover, using a dedicated bioinformatics analytical work flow, we found that the method is reproducible and applicable for label-free quantification of series of samples processed in parallel.

1 January 2016 in Journal of Proteomics
Verified
Journal Article
Closed access
CRClaire Ramus
Claire Ramus
AHAgnes Hovasse
Agnes Hovasse
MMMarlène Marcellin
Marlène Marcellin
AHAnne-Marie HESSE
Anne-Marie HESSE
EMEmmanuelle Mouton-Barbosa
Emmanuelle Mouton-Barbosa
APAnne Gonzalez de Peredo
Anne Gonzalez de Peredo

1 September 2007 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
DBDavid Bouyssié
David Bouyssié
APAnne Gonzalez de Peredo
Anne Gonzalez de Peredo
EMEmmanuelle Mouton
Emmanuelle Mouton
RARenaud Albigot
Renaud Albigot
LRLucie Roussel
Lucie Roussel
BMBernard Monsarrat
Bernard Monsarrat
Proteomics strategies based on nanoflow (nano-) LC-MS/MS allow the identification of hundreds to thousands of proteins in complex mixtures. When combined with protein isotopic labeling, quantitative comparison of the proteome from different samples can be achieved using these approaches. However, bioinformatics analysis of the data remains a bottleneck in large scale quantitative proteomics studies. Here we present a new software named Mascot File Parsing and Quantification (MFPaQ) that easily processes the results of the Mascot search engine and performs protein quantification in the case of isotopic labeling experiments using either the ICAT or SILAC (stable isotope labeling with amino acids in cell culture) method. This new tool provides a convenient interface to retrieve Mascot protein lists; sort them according to Mascot scoring or to user-defined criteria based on the number, the score, and the rank of identified peptides; and to validate the results. Moreover the software extracts quantitative data from raw files obtained by nano-LC-MS/MS, calculates peptide ratios, and generates a non-redundant list of proteins identified in a multisearch experiment with their calculated averaged and normalized ratio. Here we apply this software to the proteomics analysis of membrane proteins from primary human endothelial cells (ECs), a cell type involved in many physiological and pathological processes including chronic inflammatory diseases such as rheumatoid arthritis. We analyzed the EC membrane proteome and set up methods for quantitative analysis of this proteome by ICAT labeling. EC microsomal proteins were fractionated and analyzed by nano-LC-MS/MS, and database searches were performed with Mascot. Data validation and clustering of proteins were performed with MFPaQ, which allowed identification of more than 600 unique proteins. The software was also successfully used in a quantitative differential proteomics analysis of the EC membrane proteome after stimulation with a combination of proinflammatory mediators (tumor necrosis factor-α, interferon-γ, and lymphotoxin α/β) that resulted in the identification of a full spectrum of EC membrane proteins regulated by inflammation.

23 August 2016 in Journal of Proteome Research
Verified
Journal Article
Closed access
YVYves Vandenbrouck
Yves Vandenbrouck
LLLydie Lane
Lydie Lane
CCChristine Carapito
Christine Carapito
PDPaula Duek
Paula Duek
KRKarine Rondel
Karine Rondel
CPCharles Pineau
Charles Pineau

1 August 2012 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
VGViolette Gautier
Violette Gautier
EMEmmanuelle Mouton-Barbosa
Emmanuelle Mouton-Barbosa
DBDavid Bouyssié
David Bouyssié
NDNicolas Delcourt
Nicolas Delcourt
MBMathilde Beau
Mathilde Beau
APAnne Gonzalez de Peredo
Anne Gonzalez de Peredo
To perform differential studies of complex protein mixtures, strategies for reproducible and accurate quantification are needed. Here, we evaluated a quantitative proteomic workflow based on nanoLC-MS/MS analysis on an LTQ-Orbitrap-VELOS mass spectrometer and label-free quantification using the MFPaQ software. In such label-free quantitative studies, a compromise has to be found between two requirements: repeatability of sample processing and MS measurements, allowing an accurate quantification, and high proteomic coverage of the sample, allowing quantification of minor species. The latter is generally achieved through sample fractionation, which may induce experimental bias during the label-free comparison of samples processed, and analyzed independently. In this work, we wanted to evaluate the performances of MS intensity-based label-free quantification when a complex protein sample is fractionated by one-dimensional SDS-PAGE. We first tested the efficiency of the analysis without protein fractionation and could achieve quite good quantitative repeatability in single-run analysis (median coefficient of variation of 5%, 99% proteins with coefficient of variation <48%). We show that sample fractionation by one-dimensional SDS-PAGE is associated with a moderate decrease of quantitative measurement repeatability while largely improving the depth of proteomic coverage. We then applied the method for a large scale proteomic study of the human endothelial cell response to inflammatory cytokines, such as TNFα, interferon γ, and IL1β, which allowed us to finely decipher at the proteomic level the biological pathways involved in endothelial cell response to proinflammatory cytokines.