Jianguo Feng

Jianguo Feng

Auto-generated profile, based on publicly available information

Jianguo Feng

School of Microelectronics, Hefei University of Technology, Hefei, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
YWYe Wang
Ye Wang
HZHanliang Zhu
Hanliang Zhu
JFJianguo Feng
Jianguo Feng
PNPavel Neuzil
Pavel Neuzil

25 February 2025 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
BSBaichuan Sun
Baichuan Sun
GXGaobin Xu
Gaobin Xu
ZYZhaohui Yang
Zhaohui Yang
CGCunhe Guan
Cunhe Guan
XJXu Ji
Xu Ji
JFJianguo Feng
Jianguo Feng
Due to the limited thermoelectric (TE) performance of polymer materials and the inherent rigidity of inorganic materials, developing low-cost, highly flexible, and high-performance materials for flexible thermocouple sensors (FTCSs) remains challenging. Additionally, dual-mode (contact/non-contact) temperature monitoring in FTCSs is underexplored. This study addresses these issues by using p-type (PEDOT:PSS/CNTs, 2:1) and n-type (MXene/Bi2Se3, 2:1) TE materials applied via screen printing and compression onto a PPSN substrate (paper/PDMS/Si3N₄). The resulting FTCSs exhibit excellent TE properties: electrical conductivities of 61,197.88 S/m (n-type) and 55,697.77 S/m (p-type), Seebeck coefficients of 39.88 μV/K and -29.45 μV/K, and power factors (PFs) of 97.66 μW/mK² and 55.64 μW/mK², respectively. In contact mode, the sensor shows high-temperature sensitivity (S T = 379.5 μV/°C), a broad detection range (20-200 °C), high resolution (~0.3 °C), and fast response (~12.6 ms). In non-contact mode, it maintains good sensitivity (S Tmax = 52.67 μV/°C), a broad detection range, high resolution (~0.8 °C), and even faster response (~9.8 ms). The sensor also demonstrates strong mechanical durability, maintaining stable performance after 1000 bending cycles. When applied to dual-mode temperature monitoring in wearable devices and lithium batteries, the FTCS shows high accuracy and reliability compared to commercial K-type thermocouples, indicating significant potential for advanced medical monitoring systems and smart home technologies.

25 October 2022 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
HZHao Zhang
Hao Zhang
YCYinghao Cui
Yinghao Cui
MLMengxue Lu
Mengxue Lu
QYQingyang Yang
Qingyang Yang
JFJianguo Feng
Jianguo Feng
YYYongqiang Yu
Yongqiang Yu
Here, we presented a novel near-infrared (NIR) photodetectors based on Si micro-holes array/graphene (SiMHs/Gr) Schottky barrier diode (SBD) for monitoring heart rate. The SBD exhibited a unique self-filtered NIR response in a range from 900 nm to 1160 nm with a responsivity of 122 mA/W at zero bias voltage. Moreover, our device possessed an ultrahigh signal to noise ratio (SNR) of more than 10 5 between visible and NIR light. The presented self-filtered NIR photodetector was used as a non-contact transmission-type photoplethysmography sensor for real-time heart rate monitoring. Due to the suppression of disturbances caused by ambient light, our device performed more accurate heart rate monitoring than those extracted from commercial broadband photodetectors.

1 June 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JFJianguo Feng
Jianguo Feng
PPPavel Podesva
Pavel Podesva
HZHanliang Zhu
Hanliang Zhu
JPJan Pekarek
Jan Pekarek
CMCarmen. C. Mayorga-Martinez
Carmen. C. Mayorga-Martinez
PNPavel Neuzil
Pavel Neuzil

1 June 2021 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
JFJianguo Feng
Jianguo Feng
HZHanliang Zhu
Hanliang Zhu
JLJulius Lukeš
Julius Lukeš
MKMarie Korabečná
Marie Korabečná
ZFZdenka Fohlerová
Zdenka Fohlerová
PNPavel Neuzil
Pavel Neuzil

1 November 2024 in Fundamental Research
Verified
Journal Article
Open access
HZHanliang Zhu
Hanliang Zhu
LWLan Wang
Lan Wang
JFJianguo Feng
Jianguo Feng
PNPavel Neuzil
Pavel Neuzil
Heat generation or consumption is required for all biological processes. Microcalorimetry is an ultrasensitive method to measure heat change for various applications. In this paper, we aimed to review the ultrasensitive microcalorimeter systems and their extensive applications in bioanalysis and energy balance monitoring. We first discussed the basic structure of microcalorimeters, including the closed system and open system, temperature sensing methods, isolation materials, and temperature stabilization. Then, we focused on their applications, such as cell metabolism research, biomolecule interaction measurement, biothermal analysis, and calorimetric detection. Finally, we compared the advantages and disadvantages of commercially available microcalorimeters and their contributions to bioresearch. The development of ultrasensitive microcalorimeters provides the tools for bioanalysis at the single-cell, or even subcellular, level, as well as for precise calorimetric detection.