Luisa Ciobanu

Luisa Ciobanu

Auto-generated profile, based on publicly available information

Luisa Ciobanu

NeuroSpin, CEA, Gif-sur-Yvette, Paris-Saclay University, Saclay, France

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2002 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
LCL Ciobanu
L Ciobanu
DSD.A Seeber
D.A Seeber
CPC.H Pennington
C.H Pennington

1 June 2007 in Hearing Research
Verified
Journal Article
Closed access
TBThomas J. Brozoski
Thomas J. Brozoski
LCLuisa Ciobanu
Luisa Ciobanu
CBCarol A. Bauer
Carol A. Bauer

7 March 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
DBDavide Boido
Davide Boido
RRRavi L. Rungta
Ravi L. Rungta
BOBruno-Félix Osmanski
Bruno-Félix Osmanski
MRMorgane Roche
Morgane Roche
TTTomokazu Tsurugizawa
Tomokazu Tsurugizawa
SCSerge Charpak
Serge Charpak
Imaging based on blood flow dynamics is widely used to study sensory processing. Here we investigated the extent to which local neuronal and capillary responses (two-photon microscopy) are correlated to mesoscopic responses detected with fast ultrasound (fUS) and BOLD-fMRI. Using a specialized chronic olfactory bulb preparation, we report that sequential imaging of the same mouse allows quantitative comparison of odour responses, imaged at both microscopic and mesoscopic scales. Under these conditions, functional hyperaemia occurred at the threshold of neuronal activation and fUS-CBV signals could be detected at the level of single voxels with activation maps varying according to blood velocity. Both neuronal and vascular responses increase non-linearly as a function of odour concentration, whereas both microscopic and mesoscopic vascular responses are linearly correlated to local neuronal calcium. These data establish strengths and limits of mesoscopic imaging techniques to report neural activity.

25 June 2013 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
TTTomokazu Tsurugizawa
Tomokazu Tsurugizawa
LCLuisa Ciobanu
Luisa Ciobanu
DBDenis LE BIHAN
Denis LE BIHAN
Neuronal activity results in a local increase in blood flow. This concept serves as the basis for functional MRI. Still, this approach remains indirect and may fail in situations interfering with the neurovascular coupling mechanisms (drugs, anesthesia). Here we establish that water molecular diffusion is directly modulated by underlying neuronal activity using a rat forepaw stimulation model under different conditions of neuronal stimulation and neurovascular coupling. Under nitroprusside infusion, a neurovascular-coupling inhibitor, the diffusion response and local field potentials were maintained, whereas the hemodynamic response was abolished. As diffusion MRI reflects interactions of water molecules with obstacles (e.g., cell membranes), the observed changes point to a dynamic modulation of the neural tissue structure upon activation, which remains to be investigated. These findings represent a significant shift in concept from the current electrochemical and neurovascular coupling principles used for brain imaging, and open unique avenues to investigate mechanisms underlying brain function.

1 July 2014 in Investigative Radiology
Verified
Journal Article
Closed access
Mami IimaMami Iima
Mami Iima
OROlivier Reynaud
Olivier Reynaud
TTTomokazu Tsurugizawa
Tomokazu Tsurugizawa
LCLuisa Ciobanu
Luisa Ciobanu
JLJing-Rebecca Li
Jing-Rebecca Li
DBDenis Le Bihan
Denis Le Bihan
Purpose Our aim was to investigate the pertinence of diffusion and perfusion magnetic resonance imaging (MRI) parameters obtained at 17.2 T in a 9L glioma rat brain tumor model to evaluate tumor tissue characteristics. Materials and Methods The local animal ethics advisory committee approved this study. 9L glioma cells were injected intracerebrally to 14 Fischer rats. The animals were imaged at 7 or 12 days after implantation on a 17.2-T MRI scanner, using 72 different b values (2-3025 s/mm(2)). The signal attenuation, S/So, was fitted using a kurtosis diffusion model (ADCo and K) and a biexponential diffusion model (fractions f(fast) and f(slow) and diffusion coefficients D-fast and D-slow) using b values greater than 300 s/mm(2). To bridge the 2 models, an average diffusion coefficient and a biexponential index were estimated from the biexponential model as ADCo and K equivalents, respectively. Intravoxel incoherent motion perfusion-related parameters were obtained from the residual signal at low b values, after the diffusion component has been removed. Diffusion and perfusion maps were generated for each fitted parameter on a pixel-by-pixel basis, and regions of interest were drawn in the tumor and contralateral side to retrieve diffusion and perfusion parameters. All rats were killed and cellularity and vascularity were quantitatively assessed using histology for comparison with diffusion and perfusion parameters. Results Intravoxel incoherent motion maps clearly highlighted tumor areas as generally heterogeneous, as confirmed by histology. For diffusion parameters, ADCo and were not significantly different between the tumor and contralateral side, whereas K in the tumor was significantly higher than in contralateral basal ganglia (P < 0.0001), as well as biexponential index (P < 0.001). ADCo and in the tumor at day 7 were significantly higher than at day 12 (P < 0.01 and P < 0.001, respectively). f(IVIM) in the tumor from the kurtosis diffusion model was significantly higher than in contralateral basal ganglia (P < 0.001). f(IVIM) in the tumor at day 7 was significantly higher than in the tumor at day 12 (P < 0.0001). There was no significant difference for D* between the tumor and contralateral side (P = 0.06). A significant negative correlation was found between tumor vascularity and f(IVIM) (P < 0.05) as well as between tumor cell count and (P < 0.01). Conclusion Quantitative non-Gaussian diffusion and perfusion MRI can provide valuable information on microvasculature and tissue structure to improve characterization of brain tumors.

21 January 2012 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
RWréunion Winkeler
réunion Winkeler
RBRaphael Boisgard
Raphael Boisgard
AAAli R. Awde
Ali R. Awde
ADAlbertine Dubois
Albertine Dubois
BTBenoit Thézé
Benoit Thézé
BTBertrand Tavitian
Bertrand Tavitian
Purpose In recent years there has been an increase in the development of radioligands targeting the 18-kDa translocator protein (TSPO). TSPO expression is well documented in activated microglia and serves as a biomarker for imaging neuroinflammation. In addition, TSPO has also been reported to be overexpressed in a number of cancer cell lines and human tumours including glioma. Here we investigated the use of [18F]DPA-714, a new TSPO positron emission tomography (PET) radioligand to image glioma in vivo. Methods We studied the uptake of [18F]DPA-714 in three different rat strains implanted with 9L rat glioma cells: Fischer (F), Wistar (W) and Sprague Dawley (SD) rats. Dynamic [18F]DPA-714 PET imaging, kinetic modelling of PET data and in vivo displacement studies using unlabelled DPA-714 and PK11195 were performed. Validation of TSPO expression in 9L glioma cell lines and intracranial 9L gliomas were investigated using Western blotting and immunohistochemistry of brain tissue sections. Results All rats showed significant [18F]DPA-714 PET accumulation at the site of 9L tumour implantation compared to the contralateral brain hemisphere with a difference in uptake among the three strains (F > W > SD). The radiotracer showed high specificity for TSPO as demonstrated by the significant reduction of [18F]DPA-714 binding in the tumour after administration of unlabelled DPA-714 or PK11195. TSPO expression was confirmed by Western blotting in 9L cells in vitro and by immunohistochemistry ex vivo. Conclusion The TSPO radioligand [18F]DPA-714 can be used for PET imaging of intracranial 9L glioma in different rat strains. This preclinical study demonstrates the feasibility of employing [18F]DPA-714 as an alternative radiotracer to image human glioma.