Piero Fossati

Piero Fossati

Auto-generated profile, based on publicly available information

Piero Fossati

EBG GmbH MedAustron, Wiener Neustadt, Austria

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PFPiero Fossati
Piero Fossati
SMSilvia Molinelli
Silvia Molinelli
NMNaruhiru Matsufuji
Naruhiru Matsufuji
MCMario Ciocca
Mario Ciocca
AMAlfredo Mirandola
Alfredo Mirandola
HTHirohiko Tsujii
Hirohiko Tsujii
In carbon ion radiotherapy there is an urgent clinical need to develop objective tools for the conversion of relative biological effectiveness (RBE)-weighted doses based on different models. In this work we introduce a clinically oriented method to compare NIRS-based and LEM-based GyE systems, minimizing differences in physical dose distributions between treatment plans. Carbon ion plans were optimized on target volumes of cubic and spherical shapes, for RBE-weighted dose prescription levels ranging from 3.6 to 4.4 GyE. Plans were calculated for target sizes from 4 to 12 cm defining three beam geometries: single beam, opposed beam and orthogonal beam configurations. The two treatment planning systems currently employed in clinical practice were used, providing the NIRS-based and LEM-based GyE calculations. Physical dose distributions of NIRS-based and LEM-based treatment plans were compared. LEM-based prescription doses that minimize differences in physical dose distributions between the two systems were found. These doses were compared with the mean RBE-weighted dose obtained with a Monte Carlo code (FLUKA) interfaced with LEM I. In the investigated dose range, LEM-based RBE-weighted prescription doses, that minimize differences with NIRS plans, should be higher than NIRS reported prescription doses. The optimal dose depends on target size, shape and position, number of beams and dose level. The opposed beam configuration resulted in the smallest average prescription dose difference (0.45 ± 0.09 GyE). The second approach of recalculating NIRS RBE-weighted dose with a Monte Carlo code interfaced with LEM resulted in no significant difference with the results obtained from the planning study. The delivery of a voxel by voxel iso-effective plan, if different RBE models are employed, is not feasible; it is however possible to minimize differences in a treatment plan with the simple approach presented here. Dose prescription ultimately represents a clinical task under the responsibility of the radiation oncologist, the presented analysis intends to be a quantitative and objective way to assist the clinical decision.

9 August 2016 in World Journal of Surgical Oncology
Verified
Journal Article
Open access
PDF file
LCLorenzo Cobianchi
Lorenzo Cobianchi
APAndrea Peloso
Andrea Peloso
BVBarbara Vischioni
Barbara Vischioni
Denis PanizzaDenis Panizza
Denis Panizza
MFMaria Rosaria Fiore
Maria Rosaria Fiore
PDPaolo Dionigi
Paolo Dionigi
Sacral chordoma (SC) is a neoplasm arising from residual notochordal cells degeneration. SC is difficult to manage mainly because of anatomic location and tendency to extensive spread. Carbon ion radiotherapy (CIRT) is highly precise to selectively deliver high biological effective dose to the tumor target sparing the anatomical structure on its path even if when SC is contiguous to the intestine, and a surgical spacer might be an advantageous tool to create a distance around the target volume allowing radical curative dose delivery with a safe dose gradient to the surrounding organs. This paper describes a double approach—open and hand-assisted laparoscopic—for a silicon spacer placement in patients affected by sacral chordoma undergoing carbon ion radiotherapy. Six consecutive patients have been enrolled for surgical spacer placement—open (three) or hand-assisted (three)—prior carbon ion radiotherapy treatment in order to increase efficacy of carbon ion radiotherapy minimizing its side effects. Results showed that silicon spacer placement for SC treatment is feasible both via laparoscopic and laparotomic approach. Its use might improve CIRT safety and thus efficacy for SC treatment.

1 February 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
Guillaume VoginGuillaume Vogin
Guillaume Vogin
AWA. Wambersie
A. Wambersie
MKMasashi Koto
Masashi Koto
TOTatsuya Ohno
Tatsuya Ohno
MUMatthias Uhl
Matthias Uhl
JBJ. Balosso
J. Balosso
Carbon ion radiotherapy (CIRT) has been delivered to more than 20,000 patients worldwide. International trials have been recommended in order to emphasize the actual benefits. The ULICE program (Union of Light Ion Centers in Europe) addressed the need for harmonization of CIRT practices. A comparative knowledge of the sources and magnitudes of uncertainties altering dose distribution and clinical effects during the whole CIRT procedure is required in that aim. As part of ULICE WP2 task group, we sent a centrally reviewed questionnaire exploring candidate sources of uncertainties in dose deposition to the ten CIRT facilities in operation by February 2017. We aimed to explore native beam characterization, immobilization, anatomic data acquisition, target volumes and organs at risks delineation, treatment planning, dose delivery, quality assurance prior and during treatment. The responders had to consider the clinical case of a clival chordoma eligible for postoperative CIRT according to their clinical practice. With the results, our task group discussed ways to harmonize CIRT practices. We received 5 surveys from facilities that have treated 77% of the patients worldwide per November 2017. We pointed out the singularity of the facilities and beam delivery systems, a divergent definition of target volumes, the multiplicity of TPS and equieffective dose calculation approximations. Multiple uncertainties affect equieffective dose definition, deposition and calculation in CIRT. Although it is not possible to harmonize all the steps of the CIRT planning between the centers, our working group proposed counter-measures addressing the improvable limitations.

24 July 2012 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
KKKerstin Kessel
Kerstin Kessel
NBNina Bougatf
Nina Bougatf
CBChristian Bohn
Christian Bohn
DHDaniel Habermehl
Daniel Habermehl
DODieter Oetzel
Dieter Oetzel
SCStephanie Combs
Stephanie Combs
Background: To establish a common database on particle therapy for the evaluation of clinical studies integrating a large variety of voluminous datasets, different documentation styles, and various information systems, especially in the field of radiation oncology. Methods: We developed a web-based documentation system for transnational and multicenter clinical studies in particle therapy. 560 patients have been treated from November 2009 to September 2011. Protons, carbon ions or a combination of both, as well as a combination with photons were applied. To date, 12 studies have been initiated and more are in preparation. Results: It is possible to immediately access all patient information and exchange, store, process, and visualize text data, any DICOM images and multimedia data. Accessing the system and submitting clinical data is possible for internal and external users. Integrated into the hospital environment, data is imported both manually and automatically. Security and privacy protection as well as data validation and verification are ensured. Studies can be designed to fit individual needs. Conclusions: The described database provides a basis for documentation of large patient groups with specific and specialized questions to be answered. Having recently begun electronic documentation, it has become apparent that the benefits lie in the user-friendly and timely workflow for documentation. The ultimate goal is a simplification of research work, better study analyses quality and eventually, the improvement of treatment concepts by evaluating the effectiveness of particle therapy.