María Dolores Tenorio Sanz

María Dolores Tenorio Sanz

Auto-generated profile, based on publicly available information

María Dolores Tenorio Sanz

Department of Nutrition and Food Science, Facultad de Farmacia, Universidad Complutense de Madrid, Plaza de Ramón y Cajal, s/n, 28040 Madrid, Spain

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2020 in Exposure and Health
Verified
Journal Article
Closed access
PDF file
MGMª Concepción Almonacid Garrido
Mª Concepción Almonacid Garrido
PNPilar Jiménez Navarro
Pilar Jiménez Navarro
JAJavier Peinador Asensio
Javier Peinador Asensio
MSMª José Villanueva Suárez
Mª José Villanueva Suárez
MSMª Dolores Tenorio Sanz
Mª Dolores Tenorio Sanz

3 October 2024 in Science of The Total Environment
Verified
Journal Article
Open access
MGMaría Concepción Almonacid Garrido
María Concepción Almonacid Garrido
MVMaría José Villanueva-Suárez
María José Villanueva-Suárez
MMMaría Jesús Montes Martín
María Jesús Montes Martín
AGAlejandra Garcia-Alonso
Alejandra Garcia-Alonso
MSMaría Dolores Tenorio Sanz
María Dolores Tenorio Sanz
The presence and concentration of Legionella in drinking water supply systems, in hot water (DHW) for human consumption in public buildings in Madrid with potential health risk was studied. Sampling covered a total of 1695 DHW samples and 30 cold water (DCW) as a control taken in the 21 districts of the city over a period of 14 years (2007-2020). The detection and quantification of Legionella was carried out by plate culture and quantitative qPCR. The study evaluated a series of variables including sampling year, districts, type of building, seasonality, sampling points (taps, tanks and showers), water temperature and type of disinfection used. The degree of compliance of Legionella in the water supply network of Madrid was very high (96.1 %). The degree of colonization of the positive samples ranged from 0.3 × 103 and 1.5 × 105 GU/L for a 97 % of the samples. A higher presence of this bacterium was detected in older facilities in the peripheral districts and end points able to produce aerosols such as showers. The highest number of samples with Legionella growth occurred in the 35-40 °C range. The strategies implemented have contributed to a remarkable decrease in the presence of Legionella in the last years of sampling.

26 September 2023 in Exposure and Health
Verified
Journal Article
Open access
PDF file
MGMª Concepción Almonacid Garrido
Mª Concepción Almonacid Garrido
MVMª José Villanueva-Suárez
Mª José Villanueva-Suárez
AGAlberto Álamo Gómez
Alberto Álamo Gómez
AGAlejandra Garcia-Alonso
Alejandra Garcia-Alonso
MSMª Dolores Tenorio Sanz
Mª Dolores Tenorio Sanz
Trihalomethanes (THMs) are generated in the drinking water treatment plant, due to the reaction of the halogenated disinfection compounds with the natural organic matter (NOM). They are related to health problems both from the point of view of cancer development and other important diseases. This study aimed to assess the quality of tap water in Madrid in terms of prevention and control of THMs risks in the supply water treated by Canal de Isabel II (CYII) in a total of 108 samples throughout 2015 to 2020, to distinguish the problems of the different 21 districts or types of buildings, the seasonality and to estimate the risk of exposure to THMs from tap water in the population of Madrid. The variables considered include year, seasonality, district of Madrid and sampling point. The concentrations of THMs detected in all samples were within the current legal limit (100 µg/l). Chloroform was the compound with the highest contribution to the sum of THMs. A decreasing trend in THMs concentrations was observed over the years of the study related to the removal of NOM and the use of chloramines. THM levels were higher in the central area than in the peripheral districts and the lowest concentrations were detected in summer. Regarding risk assessment, the results of the non-carcinogenic risk indicate that there is no potential risk from tap water consumption for the adult population. For the carcinogenic risk, only water samples with THM concentrations between 50 and 75 µg/l could constitute a risk for high consumers.

5 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MGMaría Concepción Almonacid Garrido
María Concepción Almonacid Garrido
AGAlejandra Garcia-Alonso
Alejandra Garcia-Alonso
MVMaría José Villanueva-Suárez
María José Villanueva-Suárez
MTMaría Dolores Tenorio-Sanz
María Dolores Tenorio-Sanz
Domestic hot water systems are one of the most important reservoirs of Legionella. It is thought that physicochemical and microbiological water quality influences bacterial development. Accordingly, the objective of this study was to evaluate this relationship in domestic hot water in public buildings in Madrid for potential health risks and to assess the parameters that could be associated with Legionella contamination, which would assist in developing control strategies to prevent legionellosis. A total of 1695 DHW samples were evaluated over a 14-year period (2007–2020). Legionella was analysed using culture plates and qPCR. The influencing parameters (pH, electrical conductivity, colour, turbidity, Fe nitrites, and coliforms) were analysed following official methods. Furthermore, sport centre risk assessment was carried out. Legionella was isolated in 64 samples. Non-compliance levels for turbidity, colour, iron, nitrites and coliforms were found primarily in samples containing Legionella. Nitrites > 0.5 mg/L, turbidity > 1 NFU, colour ≥ 1 Pt/Co, and building type were good parameters to test Legionella colonisation. The selected influencing factors may be a useful tool for ensuring water supply quality.