Volodymyr Virt

Volodymyr Virt

Auto-generated profile, based on publicly available information

Volodymyr Virt

Lviv Polytechnic National University, Lviv, Ukraine

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017
Verified
Conference Paper
Closed access
GBGrygoriy Barylo
Grygoriy Barylo
RHRoman Holyaka
Roman Holyaka
ZHZenon Hotra
Zenon Hotra
VVVolodymyr Virt
Volodymyr Virt
FVFedir Vezyr
Fedir Vezyr
VMVistak Maria
Vistak Maria
The peculiarities of SPICE simulation of impedance spectroscopy measuring transducers are investigated in our work. On the base of model research results, an analysis method of measured values errors of the active and reactive impedance component are proposed. Our analysis method takes in to account the comparison the low-signal AC and Transient analysis. The Nyquist impedance diagrams are obtained during the AC analysis process in the idealized case, and during the Transient analysis, the active and reactive impedance components are calculated for measuring transducers actual parameters, including the activating signals forms. The implementation of such an approach is carried out by synchronous detection of output signals and integration of detection result in time range corresponding to active and reactive components. The proposed method can be used in the modeling process and sensor devices designing and in materials and nanostructures studding.

27 April 2019 in Information Technologies and Learning Tools
Verified
Journal Article
Open access
PDF file
VKVictor M. Koryahin
Victor M. Koryahin
NMNataliya Mukan
Nataliya Mukan
OBOksana Z. Blavt
Oksana Z. Blavt
VVVolodymyr V. Virt
Volodymyr V. Virt
The informatisation of modern education necessitates the development of a new model of physical education, based on interdisciplinary integrative processes using ICT. This paper considers using ICT for testing coordination skills in physical education of students. The main idea of integrating ICT into the monitoring is to intensify the pedagogical control process in order to reinforce its information capabilities. The purpose of the paper is to justify and show how to implement ICT in students’ coordination skills monitoring, while they undergo physical education. Foremost, it concerns a personalist approach to education and training, and an integrated approach in the implementation of monitoring and evaluating its results. The device that measures movement is the result of a research aimed at integrating ICT into students’ coordination skills testing. Its function is to provide a high level of control and assessment of students’ coordination skills. The device is based on the latest advances in energy-saving technologies, using optical sensors, multifunctional microcontroller development boards and software developed in Proteus Design Suite. The developed infrastructure of the device of movement control provides quick processing of received testing results using the methods of multidimensional mathematical analysis as well as the formation of integrated database for coordination skills controlling. The interface used for this provides a high level of ergonomic properties of the developed device and the possibility of effective work of specialists with the data of testing. The effectiveness of using the designed device in testing students' coordination skills is achieved through the ease of use and compactness of the device, student-friendly testing procedure and the efficiency and reliability of control. Implementation of the unique possibilities of ICT provides state-of-the-art didactic method of intensification of control process in physical education of students.

1 May 2017
Verified
Conference Paper
Closed access
GBGrygoriy Barylo
Grygoriy Barylo
RHRoman Holyaka
Roman Holyaka
VVVolodymyr Virt
Volodymyr Virt
FVFedir Vezyr
Fedir Vezyr
ZHZenon Hotra
Zenon Hotra
The main approaches to the parametric analysis of measuring transducers of galvanostatic type impedance on the base of SPICE-simulation are reviewed in the paper. The galvanostatic measuring method which is based on the basis of determining the value and the phase delays between the voltage and current harmonic defined amplitude and frequency was used in the process of simulation. As a result, the simulation found significant opportunity to improve the accuracy of measuring transformation by modifying the input circuits impedance measuring transducers.

1 February 2016
Verified
Conference Paper
Closed access
ZHZenon Hotra
Zenon Hotra
OKOleksandr Kozhukhar
Oleksandr Kozhukhar
MIMariya Ivakh
Mariya Ivakh
HBHryhoriy Barylo
Hryhoriy Barylo
VVVolodymyr Virt
Volodymyr Virt
In this paper the analysis of the prospects of creation of controlled (according to certain treatment programs) programmed devices for polychromatic therapy is conducted, the requirements to its construction and new approaches with circuit implementation of the programmed polychromatic device with new test functions and automatic adjustment of light spectrum of treatment program are provided.

1 February 2018
Verified
Conference Paper
Closed access
SOSushynskyi Orest
Sushynskyi Orest
KIKremer Iryna
Kremer Iryna
VVVirt Volodymyr
Virt Volodymyr
PRPetrina Romana
Petrina Romana
VMVistak Marija
Vistak Marija
BGBlad Grzegorz
Blad Grzegorz
The paper presents the study of liquid crystal (LC) materials with spiral structure under the influence of medicinal plant metabolites materials. Such materials are important for medicine, pharmacology and other branches of industry. The results of spectral studies of the system on the base of cholesteric liquid crystal (CLC) with quercetin make it possible to propose these materials to design the primary transducers of biological substances optical sensors. In paper shown that the solubility of quercetin in the polar nematic 5CB significantly increase compared with the steroid CLC blend BL061. The technical solution for the circuit diagram of a secondary converter of optical sensors is proposed.

1 July 2017
Verified
Conference Paper
Closed access
BGBarylo Grygoriy
Barylo Grygoriy
HRHolyaka Roman
Holyaka Roman
HZHotra Zenon
Hotra Zenon
VVVirt Volodymyr
Virt Volodymyr
VFVezyr Fedir
Vezyr Fedir
VMVistak Maria
Vistak Maria
In this paper the features of SPICE simulation of impedance spectroscopy measuring transducer considering the non-harmonic signals are presented. The detailed analysis of patterns of structural elements and functional signal transducer source are carried out. The method of improving the efficiency of model research is proposed and the corresponding SPICE model is synthesized. Designed model analyze the output parameters considering the parameters of real signals - shape, amplitude and non harmonicity. As the result of parametric analysis is not the same influence of higher harmonics in the pulse signal at different frequencies and appears differently at the results of measuring conversion. It is must be taken into account to design the signal impedance transducers.