Sean A. Woolen

Sean A. Woolen

Auto-generated profile, based on publicly available information

Sean A. Woolen

University of California, San Francisco, California, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Radiology
Verified
Journal Article
Closed access
FDFlorence X. Doo
Florence X. Doo
JVJan Vosshenrich
Jan Vosshenrich
TCTessa S. Cook
Tessa S. Cook
LMLinda Moy
Linda Moy
EAEduardo P.R.P. Almeida
Eduardo P.R.P. Almeida
KHKate Hanneman
Kate Hanneman
According to the World Health Organization, climate change is the single biggest health threat facing humanity. The global health care system, including medical imaging, must manage the health effects of climate change while at the same time addressing the large amount of greenhouse gas (GHG) emissions generated in the delivery of care. Data centers and computational efforts are increasingly large contributors to GHG emissions in radiology. This is due to the explosive increase in big data and artificial intelligence (AI) applications that have resulted in large energy requirements for developing and deploying AI models. However, AI also has the potential to improve environmental sustainability in medical imaging. For example, use of AI can shorten MRI scan times with accelerated acquisition times, improve the scheduling efficiency of scanners, and optimize the use of decision-support tools to reduce low-value imaging. The purpose of this Radiology in Focus article is to discuss this duality at the intersection of environmental sustainability and AI in radiology. Further discussed are strategies and opportunities to decrease AI-related emissions and to leverage AI to improve sustainability in radiology, with a focus on health equity. Co-benefits of these strategies are explored, including lower cost and improved patient outcomes. Finally, knowledge gaps and areas for future research are highlighted.

1 May 2023 in Radiology
Verified
Journal Article
Closed access
SWSean A. Woolen
Sean A. Woolen
ABAmy E. Becker
Amy E. Becker
AMAlastair J. Martin
Alastair J. Martin
RKRoland Knoerl
Roland Knoerl
VLVincent Lam
Vincent Lam
VDVibhas Deshpande
Vibhas Deshpande
Background Radiology is a major contributor to health care's climate footprint due to energy-intensive devices, particularly MRI which uses the most energy. Purpose To determine the energy, cost, and carbon savings that could be achieved through different scanner power management strategies. Materials and Methods In this retrospective evaluation, four outpatient MRI scanners from three vendors were individually equipped with power meters (1-Hz sampling rate). Power measurement logs were extracted over 39 days. Data were segmented into off, idle, prepared-to-scan, scan, or power-save modes for each scanner. Energy, cost (assuming a mean cost of $0.14 per kilowatt hour), and carbon savings were calculated for the lowest scanner activity modes. Data was summarized using descriptive statistics and 95% confidence intervals. Results Projected annual energy consumption per scanner ranged from 82.7-171.1 megawatt-hours (MWh), with 72-91% defined as nonproductive. Power draws for each mode were measured as 6.4 ± 0.1 kW (power-save), 7.3 ± 0.6 kW to 9.7 ± 0.2 kW (off), 9.5 ± 0.9 to 14.5 ± 0.5 kW (idle), 17.3 ± 0.5 to 25.6 ± 0.6 kW (prepared-to-scan), and 28.6 ± 8.6 to 48.3 ± 11.8 kW (scan). Switching MRIs from idle to off mode for 12 overnight hours reduced power consumption by 25-33%, translating to a potential annual savings of 12.3-21.0 MWh, $1717-$2943 U.S. dollars, and 8.7-14.9 metric tons of CO2-equivalent (MTCO2eq). The power-save mode further reduced consumption by 22-28% compared to off mode, potentially saving an additional 8.8-11.4 MWh, $1,226-$1,594 U.S. dollars, and 6.2-8.1 MTCO2eq per year for 12 hours overnight. Implementation of a power-save mode for 12 hours overnight on all U.S. outpatient MRI in the U.S. could save U.S. health care 58,863.2-76,288.2 MWh, $8.2-$10.7 million U.S. dollars, and 41,606.4-54,088.3 MTCO2eq. Conclusion Powering down MRIs can make radiology departments more energy-efficient and gain substantial sustainability and cost benefits. See also the editorial by Vosshenrich and Heye.

16 November 2022 in Academic Radiology
Verified
Journal Article
Open access
SWSean A. Woolen
Sean A. Woolen
CKChristine J. Kim
Christine J. Kim
AHAndrew M. Hernandez
Andrew M. Hernandez
ABAmy Becker
Amy Becker
AMAlastair J. Martin
Alastair J. Martin
STSean Tutton
Sean Tutton

11 June 2014 in Emergency Radiology
Verified
Journal Article
Closed access
PDF file
CAChristopher Aquino
Christopher Aquino
SWSean Woolen
Sean Woolen
SSScott D. Steenburg
Scott D. Steenburg

1 April 2025 in Radiology
Verified
Journal Article
Closed access
SWSean A. Woolen
Sean A. Woolen
VDVibhas Deshpande
Vibhas Deshpande
ABAmy E. Becker
Amy E. Becker
SDShuting Dai
Shuting Dai
PSPan Su
Pan Su
AMAlastair J. Martin
Alastair J. Martin
This study shows that MRI acceleration techniques reduce energy use, carbon emissions, and costs, while increasing imaging capacity and practice revenue, offering a sustainable and efficient strategy for health care operations.

2 March 2022 in Tomography
Verified
Journal Article
Open access
PDF file
Di SunDi Sun
Di Sun
Lubomir HadjiyskiLubomir Hadjiyski
Lubomir Hadjiyski
AAAjjai Alva
Ajjai Alva
YZYousef Zakharia
Yousef Zakharia
MJMONIKA JOSHI
MONIKA JOSHI
MMMartha Matuszak
Martha Matuszak
This observer study investigates the effect of computerized artificial intelligence (AI)-based decision support system (CDSS-T) on physicians’ diagnostic accuracy in assessing bladder cancer treatment response. The performance of 17 observers was evaluated when assessing bladder cancer treatment response without and with CDSS-T using pre- and post-chemotherapy CTU scans in 123 patients having 157 pre- and post-treatment cancer pairs. The impact of cancer case difficulty, observers’ clinical experience, institution affiliation, specialty, and the assessment times on the observers’ diagnostic performance with and without using CDSS-T were analyzed. It was found that the average performance of the 17 observers was significantly improved (p = 0.002) when aided by the CDSS-T. The cancer case difficulty, institution affiliation, specialty, and the assessment times influenced the observers’ performance without CDSS-T. The AI-based decision support system has the potential to improve the diagnostic accuracy in assessing bladder cancer treatment response and result in more consistent performance among all physicians.