Photon-counting CT has gained significant attention in recent years; however, publicly available datasets for spectral reconstruction and deep learning training remain limited. Consequently, many image process algorithms and deep learning models are developed and validated using simulated rather than real spectral CT data. To address this gap, we present a cone-beam photon-counting CT (PCCT) dataset acquired using a custom-built micro-PCCT system and 15 walnut samples. Each walnut was scanned from four bed positions under dual energy thresholds (15 keV and 30 keV), resulting in a total of 172,800 raw projection images with a resolution of 2063 × 505 pixels. The dataset provides full access to raw multi-energy projections, system parameters, calibration tables, calibration phantom raw projection data and reconstruction code, enabling comprehensive spectral CT studies including spectral CT reconstruction, material decomposition, artifact correction, and deep learning-based methods. It addresses the scarcity of real PCCT datasets for developing and validating data-driven approaches and aims to foster fair and reproducible comparisons across spectral CT image process algorithms.
31 August 2025 in Biomedical Signal Processing and Control
26 March 2026 in IEEE Transactions on Instrumentation and Measurement
Photon-counting computed tomography has demonstrated significant advancements in recent years; however, micro photon-counting CT (Micro-PCCT) systems are still limited by pixel-wise detector response nonuniformity, which degrades measurement uniformity across detector pixels and commonly produces ring artifacts in reconstructed images. Existing calibration methods exhibit limited generalizability in complex multi-material scenarios, such as contrast-enhanced imaging. This study introduces a Signal-to-Nonuniformity Error Polynomial Calibration (STEPC) framework based on measurement nonuniformity error modeling to address this issue. STEPC first fits multi-energy projections using a 2D polynomial surface to generate ideal references, then applies a nonlinear multi-energy polynomial model to predict and correct pixel-wise nonuniformity errors. The model is calibrated using homogeneous slab phantoms of different materials, including PMMA, aluminum, and iodinated contrast agents, enabling correction for both non-contrast and contrast-enhanced imaging. Experiments were performed on a custom Micro-PCCT system with phantoms and mouse. Correction performance of STEPC was evaluated using the mean local standard deviation (MLSD) in the projection domain and the ring artifact deviation (RAD) on the reconstructed images. Compared with existing methods, STEPC achieved an average MLSD reduction of at least 21.58% and reduced RAD by at least 14.18%, consistently yielding the best performance in both non-contrast and contrast-enhanced scenarios. Furthermore, STEPC can be readily extended to compensate for beam hardening effects within the same calibration framework. Quantitative material decomposition results indicate that the proposed method preserves measurement accuracy across different basis materials. These results demonstrate that STEPC provides a robust and practical calibration framework that significantly improves detector measurement uniformity in Micro-PCCT systems for multi-material spectral imaging.