Jonathan M. Taylor

Jonathan M. Taylor

Auto-generated profile, based on publicly available information

Jonathan M. Taylor

School of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ, UK

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
UBUnė G. Būtaitė
Unė G. Būtaitė
GGGraham Gibson
Graham Gibson
Ying-Lung Daniel HoYing-Lung Daniel Ho
Ying-Lung Daniel Ho
Mike TaverneMike Taverne
Mike Taverne
JTJonathan M. Taylor
Jonathan M. Taylor
DPDavid B. Phillips
David B. Phillips
Optical tweezers are a highly versatile tool for exploration of the mesoscopic world, permitting non-contact manipulation of nanoscale objects. However, direct illumination with intense lasers restricts their use with live biological specimens, and limits the types of materials that can be trapped. Here we demonstrate an indirect optical trapping platform which circumvents these limitations by using hydrodynamic forces to exert nanoscale-precision control over aqueous particles, without directly illuminating them. Our concept is based on optically actuated micro-robotics: closed-loop control enables highly localised flow-fields to be sculpted by precisely piloting the motion of optically-trapped micro-rotors. We demonstrate 2D trapping of absorbing particles which cannot be directly optically trapped, stabilise the position and orientation of yeast cells, and demonstrate independent control over multiple objects simultaneously. Our work expands the capabilities of optical tweezers platforms, and represents a new paradigm for manipulation of aqueous mesoscopic systems.

15 November 2019 in Nature Communications
Verified
Journal Article
Open access
JTJonathan M. Taylor
Jonathan M. Taylor
CNCarl J. Nelson
Carl J. Nelson
FBFinnius A. Bruton
Finnius A. Bruton
AKAryan Kaveh
Aryan Kaveh
CBCharlotte Buckley
Charlotte Buckley
MDMartin A. Denvir
Martin A. Denvir
Three-dimensional fluorescence time-lapse imaging of the beating heart is extremely challenging, due to the heart’s constant motion and a need to avoid pharmacological or phototoxic damage. Although real-time triggered imaging can computationally “freeze” the heart for 3D imaging, no previous algorithm has been able to maintain phase-lock across developmental timescales. We report a new algorithm capable of maintaining day-long phase-lock, permitting routine acquisition of synchronised 3D + time video time-lapse datasets of the beating zebrafish heart. This approach has enabled us for the first time to directly observe detailed developmental and cellular processes in the beating heart, revealing the dynamics of the immune response to injury and witnessing intriguing proliferative events that challenge the established literature on cardiac trabeculation. Our approach opens up exciting new opportunities for direct time-lapse imaging studies over a 24-hour time course, to understand the cellular mechanisms underlying cardiac development, repair and regeneration.

5 July 2024 in Science Advances
Verified
Journal Article
Open access
UBUnė G. Būtaitė
Unė G. Būtaitė
CSChristina Sharp
Christina Sharp
MHMichael Horodynski
Michael Horodynski
GGGraham Gibson
Graham Gibson
MPMiles J. Padgett
Miles J. Padgett
DPDavid B. Phillips
David B. Phillips
Optical tweezers enable noncontact trapping of microscale objects using light. It is not known how tightly it is possible to three-dimensionally (3D) trap microparticles with a given photon budget. Reaching this elusive limit would enable maximally stiff particle trapping for precision measurements on the nanoscale and photon-efficient tweezing of light-sensitive objects. Here, we customize the shape of light fields to suit specific particles, with the aim of optimizing trapping stiffness in 3D. We show, theoretically, that the confinement volume of microspheres held in sculpted optical traps can be reduced by one to two orders of magnitude. Experimentally, we use a wavefront shaping–inspired strategy to passively suppress the Brownian fluctuations of microspheres in every direction concurrently, demonstrating order-of-magnitude reductions in their confinement volumes. Our work paves the way toward the fundamental limits of optical control over the mesoscopic realm.

12 October 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
CGChiara Garbellotto
Chiara Garbellotto
JTJonathan M. Taylor
Jonathan M. Taylor
By integrating a phase-only Spatial Light Modulator (SLM) into the illumination arm of a cylindrical-lens-based Selective Plane Illumination Microscope (SPIM), we have created a versatile system able to deliver high quality images by operating in a wide variety of different imaging modalities. When placed in a Fourier plane, the SLM permits modulation of the microscope’s light-sheet to implement imaging techniques such as structured illumination, tiling, pivoting, autofocusing and pencil beam scanning. Previous publications on dedicated microscope setups have shown how these techniques can deliver improved image quality by rejecting out-of-focus light (structured illumination and pencil beam scanning), reducing shadowing (light-sheet pivoting), and obtaining a more uniform illumination by moving the highest-resolution region of the light-sheet across the imaging Field of View (tiling). Our SLM-SPIM configuration is easy to build and use, and has been designed to allow all of these techniques to be employed on an easily reconfigurable optical setup, compatible with the OpenSPIM design. It offers the possibility to choose between three different light-sheets, in thickness and height, which can be selected according to the characteristics of the sample and the imaging technique to be applied. We demonstrate the flexibility and performance of the system with results obtained by applying a variety of different imaging techniques on samples of fluorescent beads, zebrafish embryos, and optically cleared whole mouse brain samples. Thus our approach allows easy implementation of advanced imaging techniques while retaining the simplicity of a cylindrical-lens-based light-sheet microscope.

11 December 2014 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
JTJonathan M. Taylor
Jonathan M. Taylor
The constant motion of the beating heart presents an obstacle to clear optical imaging, especially 3D imaging, in small animals where direct optical imaging would otherwise be possible. Gating techniques exploit the periodic motion of the heart to computationally "freeze" this movement and overcome motion artefacts. Optically gated imaging represents a recent development of this, where image analysis is used to synchronize acquisition with the heartbeat in a completely non-invasive manner. This article will explain the concept of optical gating, discuss a range of different implementation strategies and their strengths and weaknesses. Finally we will illustrate the usefulness of the technique by discussing applications where optical gating has facilitated novel biological findings by allowing 3D in vivo imaging of cardiac myocytes in their natural environment of the beating heart.

27 April 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
VZVytautas Zickus
Vytautas Zickus
JTJonathan M. Taylor
Jonathan M. Taylor
We present SPIM-μPIV as a flow imaging system, capable of measuring in vivo flow information with 3D micron-scale resolution. Our system was validated using a phantom experiment consisting of a flow of beads in a 50 μm diameter FEP tube. Then, with the help of optical gating techniques, we obtained 3D + time flow fields throughout the full heartbeat in a ∼3 day old zebrafish larva using fluorescent red blood cells as tracer particles. From this we were able to recover 3D flow fields at 31 separate phases in the heartbeat. From our measurements of this specimen, we found the net pumped blood volume through the atrium to be 0.239 nL per beat. SPIM-μPIV enables high quality in vivo measurements of flow fields that will be valuable for studies of heart function and fluid-structure interaction in a range of small-animal models.