Kei Sano

Kei Sano

Auto-generated profile, based on publicly available information

Kei Sano

Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2024 in American Journal of Ophthalmology
Verified
Journal Article
Open access
ENEuido Nishijima
Euido Nishijima
KFKota Fukai
Kota Fukai
KSKei Sano
Kei Sano
TNTakahiko Noro
Takahiko Noro
SOShumpei Ogawa
Shumpei Ogawa
TNTadashi Nakano
Tadashi Nakano
This study sought to identify the most effective testing program for detecting visual-field defects in mild-stage glaucoma with central visual-field defects. A multicenter, retrospective diagnostic testing evaluation. The study involved 93 eyes (83 patients) with mild-stage glaucoma (median mean deviation [interquartile range]: -1.79 [2.16] dB) with central visual-field defects and 69 eyes (63 patients; median mean deviation, -1.38 [2.31] dB) with mild-stage glaucoma without central visual-field defects, from Jikei University School of Medicine and Tajimi Iwase Eye Clinic. Patients underwent 10-2 Swedish Interactive Thresholding Algorithm (SITA) Standard, 24-2 SITA Standard, and 24-2C SITA Faster tests. Central visual-field defects were defined using 10-2 SITA Standard and optical coherence tomography (OCT). A detection power of 4 points in the 24-2 that coincided with 10-2 (Center4), 12 points that lie within 10° (24-2-12), and 22 points that lie within 10° of 24-2C (24-2C-22) were analyzed using receiver operating characteristic (ROC) curves based on logistic regression analysis, using total deviation (TD) and pattern deviation (PD) probability plots. Area under the receiver operating characteristic curve (AUC) of the Center4, 24-2-12, and 24-2C-22 tests. In the upper-central visual field, AUCs of the TD plot were 0.50 (0.40-0.58) for the Center4, 0.75 (0.67-0.83) for 24-2-12, and 0.85 (0.78-0.91) for 24-2C-22, with 24-2C-22 AUC significantly exceeding 24-2-12 AUC. For the PD plot, AUCs were 0.53 (0.44-0.63), 0.81 (0.74-0.89), and 0.84 (0.77-0.90), respectively. In the lower-central visual field, using a total plot, AUCs were 0.27 (0.18-0.36), 0.57 (0.47-0.69), and 0.57 (0.46-0.68) for the Center4, 24-2-12, and 24-2C-22, respectively. Using the PD plot in the upper field, AUCs were 0.27 (0.19-0.36), 0.64 (0.53-0.75), and 0.81 (0.72-0.90), respectively, with the AUC of the 24-2C-22 significantly exceeding that of 24-2-12. The 24-2C test was significantly faster than both the 24-2 and 10-2 tests, reducing testing duration by 46% and 52%, respectively. The 24-2C SITA Faster test is highly effective and efficient for detecting mild-stage glaucoma with central visual-field defects. This, and its reduced duration, makes it a valuable tool in clinical settings.

26 September 2023 in Journal of Glaucoma
Verified
Journal Article
Open access
KSKei Sano
Kei Sano
RTRyo Terauchi
Ryo Terauchi
KFKota Fukai
Kota Fukai
YFYuko Furuya
Yuko Furuya
SNShoko Nakazawa
Shoko Nakazawa
MTMasayuki Tatemichi
Masayuki Tatemichi
Précis: In this case-control study of the Japanese population, including 3207 glaucoma cases, alcohol consumption patterns such as frequency and quantity showed a positive association with glaucoma prevalence. Purpose: To examine the association between alcohol consumption patterns and glaucoma. Subjects and Methods: This case-control study evaluated 3207 cases with glaucoma and 3207 matched controls. Patients over 40 years of age were included from 1,693,611 patients admitted to 34 hospitals in Japan. Detailed alcohol consumption patterns (drinking frequency, average daily drinks, and total lifetime drinks) were obtained, as well as various confounding factors, including smoking history and lifestyle-related comorbidities. Conditional logistic regression models were used to calculate odds ratios (ORs) and 95% CIs for glaucoma prevalence. Results: Drinking frequency showed an association with glaucoma for “a few days/week” (OR, 1.19; 95% CI, 1.03–1.38) and “almost every day/week” (OR, 1.40; 95% CI, 1.18–1.66). Average daily drinks showed an association for “>0–2 drinks/day” (OR, 1.16; 95% CI, 1.03–1.32). Total lifetime drinks showed an association for “>60–90 drink-year” (OR, 1.23; 95% CI, 1.01–1.49) and “>90 drink-year” (OR, 1.23; 95% CI, 1.05–1.44). As alcohol consumption levels differed considerably between men and women, additional analyses were conducted separately for men and women. Among men, drinking frequency of “a few days/week” and “almost every day/week,” average daily drinks of “>0–2 drinks/day” and “>2–4 drinks/day,” and total lifetime drinks of “>60–90 drink-year” and “>90 drink-year” had an association with glaucoma. Conversely, among women, neither drinking frequency, average daily drinks, nor total lifetime drinks were associated. Conclusions: Both the frequency and quantity of alcohol consumption were associated with glaucoma. Further research on gender differences is warranted.

12 September 2024 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
KIKie Iida
Kie Iida
TGToshiaki Goseki
Toshiaki Goseki
HOHiromi Onouchi
Hiromi Onouchi
KSKei Sano
Kei Sano
TNTadashi Nakano
Tadashi Nakano

28 April 2025 in Ophthalmology Science
Verified
Journal Article
Open access
KSKei Sano
Kei Sano
ENEuido Nishijima
Euido Nishijima
SSShunsuke Sumi
Shunsuke Sumi
TNTakahiko Noro
Takahiko Noro
SOShumpei Ogawa
Shumpei Ogawa
TNTadashi Nakano
Tadashi Nakano
To develop DeepISP, a deep learning model that predicts the comprehensive visual field (VF) information of the Humphrey visual field analyzer (HFA) based on rapid screening perimetry (Imo/TEMPO screening program [ISP]). A retrospective, cross-sectional, and longitudinal cohort database study. One hundred eighty-seven actual ISPs from 112 patients who underwent both ISP and HFA 24-2 on the same day at the Jikei University School of Medicine Affiliated Hospital and 3470 synthesized ISPs from 883 patients who underwent VF measurements using HFA 24-2 and HFA 10-2 at 4 hospitals affiliated with Jikei University School of Medicine. We developed 2 variants of multitask neural networks designed to predict both current VF parameters and VF progression parameters. We also evaluated the efficacy of data augmentation to synthesize ISP tests created by combining 20 points from HFA 24-2 and 8 points from HFA 10-2, with thresholding applied to these 28 points. Mean absolute error for mean deviation (MD), pattern standard deviation (PSD), and visual field index (VFI). Mean F1 score for total deviation (TD) and pattern deviation (PD) probability plot classification. Area under the curve (AUC) for MD progression (MD slope <-1.0 decibel/year) and VFI progression (VFI slope <-1.8%/year). DeepISP could predict current VF status. Mean absolute errors for predicting MD, PSD, and VFI were 1.869 ± 0.114, 1.918 ± 0.082, and 5.146 ± 0.487, respectively. The mean F1 scores for pointwise classification of TD and PD probability plots were 0.761 ± 0.002 and 0.775 ± 0.002, respectively. The AUC for classifying glaucoma hemifield test was 0.920 ± 0.008. DeepISP was also capable of predicting VF progression, with AUCs of 0.828 ± 0.060 and 0.832 ± 0.062 for predicting MD and VFI progression, respectively. We demonstrated ISP's versatility and capability in predicting comprehensive VF information, including current severity and progression risk. Our DeepISP serves as an efficient tool for screening and prioritizing patients with glaucoma for clinical intervention using only a single rapid ISP test. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

17 November 2025 in American Journal of Ophthalmology
Verified
Journal Article
Open access
KKKoji Komatsu
Koji Komatsu
YMYoichiro Masuda
Yoichiro Masuda
KSKei Sano
Kei Sano
RORyo Ohira
Ryo Ohira
SMShingo Mitooka
Shingo Mitooka
TNTadashi Nakano
Tadashi Nakano
To evaluate whether the difference between artificial intelligence (AI)-estimated retinal biological age and chronological age-the retinal age gap (RAG)-is associated with postoperative visual function after cataract surgery. Retrospective, consecutive interventional case series. Consecutive cataract surgeries at Machida Municipal Hospital (February 2024-May 2025) targeting postoperative emmetropia were included. Eligible eyes had preoperative corneal astigmatism <1 diopter and no prior ocular surgery or other ocular disease. Overall, 142 eyes (mean age, 77.6 ± 6.2 years) received a monofocal intraocular lens (IOL) or an enhanced monofocal IOL. Retinal age was estimated with the Japan Ocular Imaging Registry (JOIR) AI model, and RAG was computed as retinal age minus chronological age. Quartiles (Q1-Q4) were defined; after age matching between Q1 and Q4, 1-month outcomes-visual acuity, contrast sensitivity (CS), patient satisfaction, spectacle independence, and dysphotopsia-were compared. Multivariable logistic regression assessed factors associated with satisfaction. The JOIR model's mean absolute error was 6.98 years and root-mean-square error was 8.97 years. RAG correlated negatively with chronological age (Spearman's ρ = -0.671, P < .001). With age matching, most visual acuity and contrast sensitivity measures did not differ; however, Q1 showed higher satisfaction, higher spectacle independence, and more patients reporting no glare and no waxy vision (all P < .01). Larger RAG independently predicted lower satisfaction, irrespective of corrected distance visual acuity (P < .05). Smaller RAG was associated with greater postoperative satisfaction. RAG may serve as a practical biomarker to personalize intraocular lens selection.

1 August 2023 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
MIMasanobu Iida
Masanobu Iida
YMYoichiro Masuda
Yoichiro Masuda
KSKei Sano
Kei Sano
KIKosuke Ichihara
Kosuke Ichihara
KKKoji Komatsu
Koji Komatsu
TNTadashi Nakano
Tadashi Nakano
Purpose: To examine whether atopic cataracts are associated with thinner lenses. Setting: Department of Ophthalmology, Jikei University Hospital, Tokyo, Japan. Design: Retrospective matched case–control study. Methods: 31 eyes with atopic cataracts, 62 with nonatopic cataracts, and 31 without cataracts were analyzed. Each group was matched for age (±4 years) and sex. Results: The mean lens thickness (LT) was 3.76 ± 0.40 mm, 3.94 ± 0.49 mm, and 4.11 ± 0.40 mm in eyes with atopic cataracts, nonatopic cataracts, and normal lenses, respectively. Repeated-measures analysis of variance showed that the LT in the atopic cataract group was significantly thinner than that in the nonatopic cataract (P = .036) and normal lens (P < .001) groups. In multivariate logistic regression analysis, a thinner LT was negatively correlated with age (odds ratio [OR], 0.91; 95% CI, 0.86-0.96) and positively correlated with anterior subcapsular cataract (ASC) (OR, 5.61; 95% CI, 1.97-15.99). Atopy was not a significant factor. 24 (38.7%) of the 62 eyes with nonatopic cataracts and 24 (77.4%) of the 31 eyes with atopic cataracts had ASC. Conclusions: The lenses of eyes with atopic cataracts were thinner than those of controls. Atopic cataracts frequently present with anterior subcapsular opacity, which is associated with lens thinning.