1 September 2011 in Geophysics
We introduce a new method for first-arrival picking based on digital color-image segmentation of energy ratios of refracted seismic data. The method uses a new color-image segmentation scheme based on projection onto convex sets (POCS). The POCS requires a reference color for the first break and one iteration to segment the first-break amplitudes from other arrivals. We tested the segmentation method on synthetic seismic data sets with various amounts of additive Gaussian noise. The proposed method gives similar performance to a modified version of Coppens’ method for traces with high signal-to-noise ratio and medium-to-large offsets. Finally, we applied our method and used as well the modified first-arrival picking method based on Coppens’ method to pick the first arrivals on four real data sets, where both were compared to the first breaks that were picked manually and then interpolated. Based on an assessment error of a 20-ms window with respect to manual picks that are interpolated, we find that our method gives comparable performance to Coppens’ method, depending on the data difficulty of picking first arrivals. Therefore, we believe that our proposed method is a good new addition to the existing methods of first-arrival picking.
27 March 2019 in Arabian Journal of Geosciences
7 May 2025 in Scientific Reports
In bioturbated strata, defining and obtaining a representative elementary volume for permeability measurements presents significant challenges. To address this, spot permeability is often used as an alternative method to estimate the bulk permeability of these complex strata. However, laboratory measurements of spot permeability require steady-state nitrogen gas injection and careful sample preparation including slab cutting which makes the process both time-consuming and resource-intensive. Alternatively, field measurements using portable devices offer a more cost-effective, straightforward, and real-time approach for assessing permeability in situ. To evaluate the accuracy of portable devices in measuring spot permeability in bioturbated strata, we compare and contrast permeability measurements on the same rock samples (from the Hanifa Formation in central Saudi Arabia) using two different techniques: the sophisticated laboratory-based AutoScan system and the portable TinyPerm 3 field device both from New England Research (NER). Two sets of permeability data comprising 64 measurements were obtained and analyzed graphically using Whisker Box Plots, Bland-Altman Plot, Curve Matching, and Cross Plots, as well as statistically through correlation analysis and analysis of variance (ANOVA). The graphical analysis revealed no substantial difference in permeability measured by the two methods, a finding further supported by ANOVA results, which indicated no statistically significant difference (P-value > 0.05). Additionally, the correlation plot between the permeability measurements from the two methods yielded a straight line with an R $$^2$$ value greater than 0.9, demonstrating a strong agreement. This study highlights the potential of using portable handheld permeameters to measure spot permeability of bioturbated strata in the field, offering a cost-effective, accurate, and real-time alternative to laboratory-based techniques in estimating their bulk permeability.
25 January 2013 in Arabian Journal of Geosciences