Rune Boas

Rune Boas

Auto-generated profile, based on publicly available information

Rune Boas

Department of Cardiology, Amager Hvidovre University Hospital, University of Copenhagen, Denmark (R.B., U.D.).

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2022 in Circulation
Verified
Journal Article
Closed access
PDF file
RBRune Boas
Rune Boas
NSNikolay Sappler
Nikolay Sappler
LSLukas von Stülpnagel
Lukas von Stülpnagel
MKMathias Klemm
Mathias Klemm
UDUlrik Dixen
Ulrik Dixen
KRKonstantinos D. Rizas
Konstantinos D. Rizas
Background: Identification of patients with nonischemic cardiomyopathy who may benefit from prophylactic implantation of a cardioverter-defibrillator. We hypothesized that periodic repolarization dynamics (PRD), a marker of repolarization instability associated with sympathetic activity, could be used to identify patients who will benefit from prophylactic implantable cardioverter defibrillator (ICD) implantation. Methods: We performed a post hoc analysis of DANISH (Danish ICD Study in Patients With Dilated Cardiomyopathy), in which patients with nonischemic cardiomyopathy, left ventricular ejection fraction (LVEF) ≤35%, and elevated NT-proBNP (N-terminal probrain natriuretic peptides) were randomized to ICD implantation or control group. Patients were included in the PRD substudy if they had a 24-hour Holter monitor recording at baseline with technically acceptable ECG signals during the night hours (00:00–06:00). PRD was assessed using wavelet analysis according to previously validated methods. The primary end point was all-cause mortality. Cox regression models were adjusted for age, sex, NT-proBNP, estimated glomerular filtration rate, LVEF, atrial fibrillation, ventricular pacing, diabetes, cardiac resynchronization therapy, and mean heart rate. We proposed PRD ≥10 deg 2 as an exploratory cut-off value for ICD implantation. Results: A total of 748 of the 1116 patients in DANISH qualified for the PRD substudy. During a mean follow-up period of 5.1±2.0 years, 82 of 385 patients died in the ICD group and 85 of 363 patients died in the control group ( P =0.40). In Cox regression analysis, PRD was independently associated with mortality (hazard ratio [HR], 1.28 [95% CI, 1.09–1.50] per SD increase; P =0.003). PRD was significantly associated with mortality in the control group (HR, 1.51 [95% CI, 1.25–1.81]; P <0.001) but not in the ICD group (HR, 1.04 [95% CI, 0.83–1.54]; P =0.71). There was a significant interaction between PRD and the effect of ICD implantation on mortality ( P =0.008), with patients with higher PRD having greater benefit in terms of mortality reduction. ICD implantation was associated with an absolute mortality reduction of 17.5% in the 280 patients with PRD ≥10 deg 2 (HR, 0.54 [95% CI, 0.34–0.84]; P =0.006; number needed to treat=6), but not in the 468 patients with PRD <10 deg 2 (HR, 1.17 [95% CI, 0.77–1.78]; P =0.46; P for interaction=0.01). Conclusions: Increased PRD identified patients with nonischemic cardiomyopathy in whom prophylactic ICD implantation led to significant mortality reduction.

30 November 2020 in EP Europace
Verified
Journal Article
Closed access
RBRune Boas
Rune Boas
JTJens Jakob Thune
Jens Jakob Thune
SPSteen Pehrson
Steen Pehrson
LKLars Køber
Lars Køber
JNJens C Nielsen
Jens C Nielsen
UDUlrik Dixen
Ulrik Dixen
Aims: Improved risk stratification to identify non-ischaemic heart failure patients who will benefit from primary prophylactic implantable cardioverter-defibrillator (ICD) is needed. We examined the potential of ventricular arrhythmia to identify patients who could benefit from an ICD. Methods and results: A total of 850 non-ischaemic systolic heart failure patients with left ventricle ≤35% and elevated N-terminal pro-brain natriuretic peptides had a 24-h Holter monitor recording performed. We examined present non-sustained ventricular tachycardia (NSVT), defined as ≥3 consecutive premature ventricular contractions (PVCs) with a rate of ≥100/min, and number of PVCs per hour stratified into low (<30) and high burden (≥30) groups. Outcome measures were overall mortality, sudden cardiac death (SCD), and cardiovascular death (CVD). In total, 193 patients died, 49 from SCD and 125 from CVD. Non-sustained ventricular tachycardia (365 patients) was significantly associated with increased all-cause mortality [hazard ratio (HR) 1.47; 95% confidence interval (CI) 1.07–2.03; P = 0.02] and to CVD (HR 1.89; CI 1.25–2.87; P = 0.003). High burden PVC (352 patients) was associated with increased all-cause mortality (HR1.38; CI 1.00–1.90; P = 0.046) and with CVD (HR 1.78; CI 1.19–2.66; P = 0.005). There was no statistically significant association with SCD for neither NSVT nor PVC. In interaction analyses, neither NSVT (P = 0.56) nor high burden of PVC (P = 0.97) was associated with survival benefit from ICD implantation. Conclusion: Ventricular arrhythmia in non-ischaemic heart failure patients was associated with a worse prognosis but could not be used to stratify patients to ICD implantation.

1 February 2021 in American Heart Journal
Verified
Journal Article
Closed access
RBRune Boas
Rune Boas
JTJens Jakob Thune
Jens Jakob Thune
SPSteen Pehrson
Steen Pehrson
LKLars Køber
Lars Køber
JNJens C. Nielsen
Jens C. Nielsen
UDUlrik Dixen
Ulrik Dixen