Christoph Germann

Christoph Germann

Auto-generated profile, based on publicly available information

Christoph Germann

Department of Radiology, Balgrist University Hospital, University of Zurich, Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Investigative Radiology
Verified
Journal Article
Closed access
CGChristoph Germann
Christoph Germann
DNDaniel Nanz
Daniel Nanz
RSReto Sutter
Reto Sutter
During the last decade, metal artifact reduction in magnetic resonance imaging (MRI) has been an area of intensive research and substantial improvement. The demand for an excellent diagnostic MRI scan quality of tissues around metal implants is closely linked to the steadily increasing number of joint arthroplasty (especially knee and hip arthroplasties) and spinal stabilization procedures. Its unmatched soft tissue contrast and cross-sectional nature make MRI a valuable tool in early detection of frequently encountered postoperative complications, such as periprosthetic infection, material wear–induced synovitis, osteolysis, or damage of the soft tissues. However, metal-induced artifacts remain a constant challenge. Successful artifact reduction plays an important role in the diagnostic workup of patients with painful/dysfunctional arthroplasties and helps to improve patient outcome. The artifact severity depends both on the implant and the acquisition technique. The implant's material, in particular its magnetic susceptibility and electrical conductivity, its size, geometry, and orientation in the MRI magnet are critical. On the acquisition side, the magnetic field strength, the employed imaging pulse sequence, and several acquisition parameters can be optimized. As a rule of thumb, the choice of a 1.5-T over a 3.0-T magnet, a fast spin-echo sequence over a spin-echo or gradient-echo sequence, a high receive bandwidth, a small voxel size, and short tau inversion recovery–based fat suppression can mitigate the impact of metal artifacts on diagnostic image quality. However, successful imaging of large orthopedic implants (eg, arthroplasties) often requires further optimized artifact reduction methods, such as slice encoding for metal artifact correction or multiacquisition variable–resonance image combination. With these tools, MRI at 1.5 T is now widely considered the modality of choice for the clinical evaluation of patients with metal implants.

6 November 2020 in Skeletal Radiology
Verified
Journal Article
Open access
PDF file
CGChristoph Germann
Christoph Germann
RSReto Sutter
Reto Sutter
DNDaniel Nanz
Daniel Nanz
Pacinian corpuscles represent special nerve endings that serve as mechanoreceptors sensitive to vibration and pressure and are crucial for proprioception. This work demonstrates that the complex network of Pacinian corpuscles in hands and feet can be examined with three-dimensional Dual Echo Steady State (DESS) MR imaging at 7 T, while previous dedicated MRI reports were either limited to two-dimensional images or focused on the hands. The high-resolution MR images show the detailed architecture of the complex receptor network and reveal a “chain-like” arrangement of Pacinian corpuscles, a predilection for clustering around metacarpophalangeal/metatarsophalangeal joints, proximal phalanges and fingertips, and specific sensor locations both in the superficial subcutaneous tissue and adjacent to deep soft tissue structures such as tendons and joint capsules.

1 August 2020 in CARTILAGE
Verified
Journal Article
Open access
PDF file
FCFabio A. Casari
Fabio A. Casari
CGChristoph Germann
Christoph Germann
LWLizzy Weigelt
Lizzy Weigelt
SWStephan Hermann Wirth
Stephan Hermann Wirth
AVArnd Viehöfer
Arnd Viehöfer
JAJakob Ackermann
Jakob Ackermann
To determine the role of magnetic resonance imaging (MRI) MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) 1 and 2.0 scores in the assessment of postoperative outcome after autologous matrix-induced chondrogenesis (AMIC) for the treatment of osteochondral lesions of the talus (OLTs). It was hypothesized that preoperative patient factors or OLT morphology are associated with postoperative MOCART scores; yet postoperative clinical outcome is not. Cohort study; Level of evidence, 4. This study evaluated isolated AMIC that were implanted on the talus of 35 patients for the treatment of symptomatic OLT. Tegner and AOFAS (American Orthopaedic Foot and Ankle Society) scores were obtained at an average follow-up of 4.5 ± 1.8 years and postoperative MRI scored according to the MOCART 1 and 2.0. OLT size showed significant correlation with postoperative MRI scores (MOCART 1: P = 0.006; MOCART 2.0: P = 0.004). Bone grafting was significantly associated with a MOCART 1 subscale (signal intensity of repair tissue; P = 0.038). Age and defect size showed significant correlations with MOCART 2.0 subscales (P < 0.05). Patients with shorter follow-up had a significantly higher MOCART 1 score and a trend toward better MOCART 2.0 scores than patients with longer follow-up (64.7 vs. 52.9 months, P = 0.02; 69.4 vs. 60.6 months, P = 0.058). No MOCART score was associated with postoperative patient-reported outcomes (n.s.). Osteochondral lesion size is associated with postoperative MOCART scores in patients treated with AMIC for OLTs, with decreasing MOCART scores over time. Yet clinical outcome does not correlate with any MOCART score. Thus, MOCART assessment seems to have no significant role in the postoperative treatment of asymptomatic patients that underwent AMIC for OLTs.

28 December 2022 in European Radiology
Verified
Journal Article
Open access
PDF file
CGChristoph Germann
Christoph Germann
AMAndré N. Meyer
André N. Meyer
MSMatthias Staib
Matthias Staib
RSReto Sutter
Reto Sutter
BFBenjamin Fritz
Benjamin Fritz
Objectives: The aim is to validate the performance of a deep convolutional neural network (DCNN) for vertebral body measurements and insufficiency fracture detection on lumbar spine MRI. Methods: This retrospective analysis included 1000 vertebral bodies in 200 patients (age 75.2 ± 9.8 years) who underwent lumbar spine MRI at multiple institutions. 160/200 patients had ≥ one vertebral body insufficiency fracture, 40/200 had no fracture. The performance of the DCNN and that of two fellowship-trained musculoskeletal radiologists in vertebral body measurements (anterior/posterior height, extent of endplate concavity, vertebral angle) and evaluation for insufficiency fractures were compared. Statistics included (a) interobserver reliability metrics using intraclass correlation coefficient (ICC), kappa statistics, and Bland-Altman analysis, and (b) diagnostic performance metrics (sensitivity, specificity, accuracy). A statistically significant difference was accepted if the 95% confidence intervals did not overlap. Results: The inter-reader agreement between radiologists and the DCNN was excellent for vertebral body measurements, with ICC values of > 0.94 for anterior and posterior vertebral height and vertebral angle, and good to excellent for superior and inferior endplate concavity with ICC values of 0.79–0.85. The performance of the DCNN in fracture detection yielded a sensitivity of 0.941 (0.903–0.968), specificity of 0.969 (0.954–0.980), and accuracy of 0.962 (0.948–0.973). The diagnostic performance of the DCNN was independent of the radiological institution (accuracy 0.964 vs. 0.960), type of MRI scanner (accuracy 0.957 vs. 0.964), and magnetic field strength (accuracy 0.966 vs. 0.957). Conclusions: A DCNN can achieve high diagnostic performance in vertebral body measurements and insufficiency fracture detection on heterogeneous lumbar spine MRI. Key Points: • A DCNN has the potential for high diagnostic performance in measuring vertebral bodies and detecting insufficiency fractures of the lumbar spine.

28 May 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
CGChristoph Germann
Christoph Germann
JGJulien Galley
Julien Galley
AFAnna L. Falkowski
Anna L. Falkowski
SFSandro F. Fucentese
Sandro F. Fucentese
CPChristian W. A. Pfirrmann
Christian W. A. Pfirrmann
RSReto Sutter
Reto Sutter
Objectives: To test the diagnostic accuracy of a 3D dual-echo steady-state (DESS) sequence at 7-T MRI regarding the detection of chondral calcific deposits of the knee in comparison to 3-T MRI, using CT as cross-sectional imaging reference standard. Methods: CT and 7-T MRI (DESS) of knee joints in 42 patients with radiographically known chondrocalcinosis (13 of 42 bilateral) were prospectively acquired for all included patients (n = 55 knee joints). Additionally, 3-T MRI (DESS) was performed for 20 of these 55 knee joints. Two fellowship-trained musculoskeletal radiologists scored eight cartilage regions of each knee joint separately regarding presence of cartilage calcification, diagnostic confidence level, and sharpness of calcific deposits. In an explorative subanalysis, micro-CT of the menisci was evaluated after knee arthroplasty in one patient. Diagnostic performance metrics and nonparametric tests were used to compare between modalities. p values < 0.05 were considered to represent statistical significance. Results: Sensitivity for chondrocalcinosis detection was significantly higher for 7-T MRI (100%) compared to 3-T MRI (reader 1: 95.9%, p = 0.03; reader 2: 93.2%, p = 0.002). The diagnostic confidence was significantly higher for both readers at 7 T compared to both 3-T MRI (p < 0.001) and to CT (p = 0.03). The delineation of chondral calcifications was significantly sharper for 7-T compared to both 3-T MRI and CT (p < 0.001, both readers). Micro-CT in one patient suggested that 7-T MRI may potentially outperform standard CT in diagnosing chondral calcifications. Conclusion: 3D-DESS imaging at 7-T MRI offers a significantly higher sensitivity in detection of chondral calcific deposits compared to 3-T MRI. Key Points: • 3D dual-echo steady-state (DESS) MRI at 7 T has a higher sensitivity in detection of chondral calcific deposits compared to 3-T MRI (p ≤ 0.03). • 3D DESS MRI at 7 T yields no false-negative cases regarding presence of chondral calcific deposits. • 3D DESS MRI at 7 T offers better delineation and higher diagnostic confidence in detection of chondral calcific deposits compared to 3-T MRI (p < 0.001).

22 June 2022 in Osteoarthritis and Cartilage Open
Verified
Journal Article
Open access
SDStefan Dudli
Stefan Dudli
AKAgnieszka Karol
Agnieszka Karol
LGLuca Giudici
Luca Giudici
IHIrina Heggli
Irina Heggli
CLChristoph J. Laux
Christoph J. Laux
MFMazda Farshad
Mazda Farshad
Modic changes (MC) are vertebral bone marrow lesions seen on magnetic resonance images, that associate with disc degeneration and low back pain (LBP). Few studies described MC histopathology qualitatively based on a few patient samples. CD90-positive bone marrow stromal cells were shown to be pro-fibrotic in MC. We aimed to provide the first semi-quantitative histomorphometric analysis of MC bone marrow. We hypothesized a role of CD90-positive cells in MC pathomechanisms. Human biopsies from Modic type 1 changes (MC1, n ​= ​8), Modic type 2 changes (MC2, n ​= ​6), and control biopsies (MC0, n ​= ​8) from adjacent vertebrae were obtained from 14 LBP patients during lumbar spinal fusion. Biopsies were processed for histology/immunohistochemistry. Inflammatory changes (oedema, inflammatory infiltrates), fibrotic changes (connective tissue, type I and III collagen, fibronectin, α-smooth muscle actin), and amount of bone marrow stromal cells (CD90, CD105) were scored. Scores for MC0, MC1, and MC2 were compared with non-parametric tests. Pairwise correlations, hierarchical clustering, and principal component analysis of histological readouts were calculated to identify most important histomorphometric MC characteristics. Compared to MC0, MC1 had more connective tissue, oedema, inflammatory infiltrates, and CD90+ cells. MC2 compared to MC0 had more oedema and CD90+ cells. Scores of CD90 correlated and clustered with inflammatory and fibrotic changes. Amount of connective tissue correlated with LBP. Accumulation of CD90+ cells is a major characteristic of MC in patients undergoing lumbar spinal fusion and associates with inflammatory and fibrotic changes. Therefore, CD90+ cells may play an important role in the inflammatory-fibrotic pathomechanisms of MC.