Tatiana Y. Chichkova

Tatiana Y. Chichkova

Auto-generated profile, based on publicly available information

Tatiana Y. Chichkova

Research Institute for Complex Issues of Cardiovascular Diseases

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
SMSergey Mamchur
Sergey Mamchur
TCTatiana Chichkova
Tatiana Chichkova
EKEgor Khomenko
Egor Khomenko
AKAlexander Kokov
Alexander Kokov
The aim of this paper is to evaluate the effect of pulmonary vein (PV) morphometric characteristics and spatial orientation on the results of cryoballoon ablation (CBA). Methods: A randomized, prospective, single-center controlled study was conducted, enrolling 230 patients with drug-refractory atrial fibrillation (AF). We compared procedural and long-term outcomes in patients who underwent their first procedure of pulmonary vein isolation (PVI) for AF with either radiofrequency ablation (RFA) (n = 108) or CBA (n = 122) and assessed their interaction with the different pattern of PV anatomy, morphometric characteristics, and spatial orientation. The primary efficacy endpoint was any documented atrial arrhythmia recurrence (AF, atrial flutter, or atrial tachycardia) lasting over 30 s during a 12-month follow-up after a 90-day blanking period and discontinuation of antiarrhythmic drugs. The procedure’s endpoint was the achievement of PVI. Before the intervention, all patients underwent computed tomography (CT) to assess the PV anatomical variant, maximum and minimum diameters of the PV’s ostia, their cross-sectional area, orifice ovality index, and PV tilt angles. Results: The mean follow-up period was 14 months (12; 24). Long-term efficacy in the cryoablation group was 78.8% and in the RFA group—83.3% (OR = 0.74; 95% CI 0.41–1.3; p = 0.31). The RFA results did not depend on PV anatomy. The «difficult» occlusion of the right inferior PV (RIPV) occurred in 12 patients and was associated with a more horizontal PV position in the frontal plane; the mean tilt angle was −15.2 ± 6.2° versus −26.5 ± 6.3° in the absence of technical difficulties (p = 0.0001). In 11 cases (9%), during ablation of the right superior PV (RSPV), phrenic nerve injury (PNI) occurred and was associated with the maximum and minimum RSPV diameter, 20.0–20.4 mm (OR = 13.2; 95% CI: 4.7–41.9, p < 0.05) and 17.5–20 mm (OR = 12.5; 95% CI 3.4–51, p < 0.05), respectively. Patients with arrhythmia recurrence were characterized by significantly larger diameters and ovality of the left superior PV (LSPV). The spatial orientation of the PV does not affect the long-term results of cryoablation. Conclusion: Preprocedural evaluation of PV morphology and orientation using cardiac CT might help choose the optimal technology for the individual patient.

17 January 2020 in Complex Issues of Cardiovascular Diseases
Verified
Journal Article
Open access
PDF file
TCT. Yu. Chichkova
T. Yu. Chichkova
SMSergey Mamchur
Sergey Mamchur
EKE. A. Khomenko
E. A. Khomenko
MRM. P. Romanova
M. P. Romanova
AKAlexander Kokov
Alexander Kokov
Aim. To estimate the efficacy of pulmonary veins (PV) cryoballoon isolation in its different anatomical variants.Methods. 230 patients 57 (53; 62) years of age were enrolled in the study in approximately equal proportion of males and females. Up to 1/3 of patients suffered from isolated AF, most of them belonged to the category of high risk of thromboembolic complications. To evaluate the PV anatomical variant, a modified classification of E. Marom et al was used. In groups of cryoballoon and radio-frequency isolation, subgroups of typical and variant anatomy were distinguished. Evaluation of the effectiveness of the intervention was based on the identification of any (symptomatic and asymptomatic) documented episodes of atrial arrhythmias lasting more than 30 seconds during the observation period of 12 months.Results. Comparison of efficacy in typical PV anatomy did not reveal significant differences between cryo and RFA groups, regardless of the type of device used. Subgroup I of generation of cryoballoons showed freedom from AF 83.2%, II generation – 87.5%, RFA group – 82.7% at p = 0.82. At the same time, with PV variant anatomy, the efficiency of cryo isolation with the use of II generation devices was 52.2 versus 85.7% in the RFA group (OR = 0.25; 95% CI 0.09–0.71; p = 0, 02). When analyzing long-term results in cryo and RFA groups depending on the anatomical variant, it was found that with RFA, the presence of a left PV common trunk (collector / vestibule), as well as the presence of additional veins, showed results comparable with the group of typical anatomy. At the same time, in the cryoablation group, the presence of a left common trunk was accompanied by a decrease in efficiency to 23.1 versus 84.9% for typical anatomy (OR = 0.14; 95% CI 0.03–0.6; p = 0.02) and 90% in the presence of additional veins (OR = 0.1; 95% CI 0.01–0.64; p = 0.02). In the presence of a left common trunk, the efficiency of cryoablation using second-generation cylinders was 23.1 versus 82.4% in the RFA group (OR = 0.16; 95% CI 0.05–0.5).Conclusion. The presence of a left PV common trunk leads to a decrease in the effectiveness of cryoablation in the long-term observation period relative to the group of typical anatomy to 23.1 versus 84.9% (OR = 0.14; 95% CI 0.03–0.6) and 82.4% for radiofrequency ablation (OR = 0.16; 95% CI 0.05–0.5). The presence of additional veins of right-sided localization does not affect the effectiveness of the intervention.

28 December 2019 in Fundamental and Clinical Medicine
Verified
Journal Article
Open access
PDF file
TCT. Yu. Chichkova
T. Yu. Chichkova
SMSergey Mamchur
Sergey Mamchur
MRM. P. Romanova
M. P. Romanova
EKE. A. Khomenko
E. A. Khomenko
Aim. To estimate the dynamics of 24-hour blood pressure pattern in patients with resistant hypertension after renal denervation in comparison with the conservative treatment group.Methods. We enrolled 45 patients (21 men and 24 women, mean age 53 (43-66) years) with resistant hypertension. Renal denervation was performed in 25 patients using Vessix renal denervation system while the conservative treatment group included 20 patients. Monitoring of 24-hour blood pressure pattern was performed before renal denervation and after 1 year of follow-up.Results. Twelve months after renal denervation, patients with resistant hypertension had a significant reduction in office blood pressure (33 and 15 mmHg for systolic and diastolic blood pressure, respectively) and 24-hour average blood pressure (29 and 12 mmHg, for systolic and diastolic blood pressure, respectively). Another beneficial effect of renal denervation was a decrease in systolic blood pressure variability both throughout the day and at night (6 (5-12) and 7 (7-10) mmHg, respectively); however, no changes in diastolic blood pressure variability have been registered. Despite renal denervation did not affect the morning blood pressure surge, morning systolic blood pressure reduced from 174 (130180) mmHg to 156 (130-165) mmHg. After 1 year of follow-up, the proportion of dippers increased from 16 to 44%. In contrast to the patients who underwent renal denervation, there were no significant changes in 24-hour blood pressure pattern in the conservative treatment group.Conclusion. After 1 year of follow-up, renal denervation can be considered as an option superior to conservative treatment in patients with resistant hypertension, as it significantly improved 24-hour blood pressure pattern.

11 July 2019 in Siberian Journal of Clinical and Experimental Medicine
Verified
Journal Article
Open access
SMSergey Mamchur
Sergey Mamchur
EIE. A. Ivanitskiy
E. A. Ivanitskiy
OPO. M. Polikutina
O. M. Polikutina
TCT. Yu. Chichkova
T. Yu. Chichkova
IMI. N. Mamchur
I. N. Mamchur
EKE. A. Khomenko
E. A. Khomenko
Aim. To estimate the efficacy of invasive and non-invasive long-term ECG monitoring in comparison with conventional follow-up for the detection of silent atrial fibrillation (AF)/atrial flutter (AFL)/atrial tachycardia (AT) in patients with a cryptogenic stroke.Methods. The randomized, prospective, two-center study enrolled 36 patients who suffered cryptogenic stroke (CS) or transient ischemic attack (TIA) without past history of AF/AFL/AT. Patients were randomized in a 1:1:1 ratio to one of the three ECG monitoring strategies: standard arrhythmia monitoring (group I, n=12), ECG-monitoring with implantable loop recorder (group II, n=12), and ambulatory noninvasive ECG monitoring (group III, n=12). The primary endpoint was the time to the first detection of AF/AFL/AT. Patients, assigned to the group I, underwent an assessment at scheduled and unscheduled visits and received ambulatory ECG monitoring 28 days and 1 year after randomization. Patients in the group II underwent implantation of Reveal XT (Medtronic, USA) with the daily remote data transmission to CareLink Network. In the group III, for long-term external monitoring, Spyder system (WEB Biotechnology, Singapore) was used for up to 28 days.Results. During the first 28 days of observation, there were no significant differences in AF detection rates between groups I, II, and III: 0 (0%), 1 (8%), and 2 (17%) cases, respectively, р=0.537. During the year of observation, AF/AFL/AT episodes were detected in 1 case (8%) in the group I, 6 cases (50%) in the group II, and 2 cases (17%) in the group III, p=0.0486. The mean time from enrollment into the study to detection of the first AF/AFL/AT episode was 67 days (15; 97) in all groups. In the groups II and III, the first arrhythmia episodes were detected by monitoring devices on days 24 and 6, respectively. In most cases, arrhythmia episodes detected by long-term monitoring were asymptomatic. Recurrent stroke or TIA events occurred in group I and III (1 case in each group), but not in the group with implantable cardiac monitors. Subgroup analysis showed that significantly higher AF/AFL/AT detection rate was associated with stroke, CHA2DS2VASc score ≥2, and the presence of hypertension. For the 12 months of follow-up, the mean AF burden in the group II was 0.4 (0.2; 0.5) hours per day (1.6%). In the patients with recurrent stroke, AF burden was 3.2% compared to 0.9% in the rest of patients.Conclusion. Detection of silent AF with implantable cardiac monitors is superior to standard and long-term external monitoring in cryptogenic stroke patients.

25 July 2019 in Annals of Noninvasive Electrocardiology
Verified
Journal Article
Closed access
PDF file
SMSergey Mamchur
Sergey Mamchur
EKEgor A. Khomenko
Egor A. Khomenko
TCTatiana Y. Chichkova
Tatiana Y. Chichkova
MRMaria P. Romanova
Maria P. Romanova
VEVeronika V. Evtushenko
Veronika V. Evtushenko
OPOlga M. Polikutina
Olga M. Polikutina

3 February 2019 in Complex Issues of Cardiovascular Diseases
Verified
Journal Article
Open access
PDF file
TCT. Y. Chichkova
T. Y. Chichkova
SMSergey Mamchur
Sergey Mamchur
EKE. A. Khomenko
E. A. Khomenko
Aim. To estimate the clinical success of cryoballoon pulmonary vein isolation (PVI).Methods.230 patients (males: 49.6%, mean age 57 (53; 62) with symptomatic paroxysmal and persistent atrial fibrillation (AF) resistant to antiarrhythmic therapy were included in a single-center prospective study. The patients were randomized into 2 groups to undergo either cryoballoon ablation (n = 122) or radiofrequency (RF) (n = 108) ablation. Both groups were comparable in baseline parameters. The follow-up period was 12 months. Clinical outcomes were estimated with the use of a three-stage scale. The rates of cardiovascular rehospitalizations, direct-current cardioversions and repeated ablations during were estimated within the follow-up. The quality of life (QoL) in the cryoablation group was measured using the AFEQT scale.Results.77% (n = 94) of patients in the cryoballoon ablation group and 71.3% (n = 77) of patients in the RF group (р = 0.71) demonstrated reported the optimal clinical effects. Both groups, cryo ablation and RF ablation, had similar rates of cardiovascular hospitalizations (23.8 vs 28.7%, OR 0.8, 95% CI 0.4–1.4; р = 0.39), direct-current cardioversions (12.3 vs 17.6%, OR 0.7, 95% CI 0.3–1.4; р = 0.26) and repeated ablations (9.8–11.1%, OR 0.9, 95% CI 0.4–2.0; р = 0.75). The patients treated with cryoballoon as opposed to RF ablation had significantly more successful usage of “pill-in-pocket” strategy – 14.8 vs 6.5% (OR 2.5, 95% CI 1.01–6.2; р = 0.04). Significant improvements of the QoL parameters with strong size effect have been found in the cryoablation group, i.e. global score (GS) increased by 8.9±6.9 (95% CI 6.6–10.1; dCohen 1.2; р<0.001), symptoms (S) – by 8.3±7.9 (95% CI 4.2–8.8; dCohen 1.5; р<0.001), daily activities (DA) – by 10.0±6.9 (95% CI = 6.4–10.6; dCohen 0.9; р<0.001), treatment concerns (TC) – by 5.5±6.0 (95% CI 6.3–9.2; dCohen 1.2; р<0.001) and treatment satisfaction (TS) – by 5.5±6.0 (95% CI 5.4–9.8; dCohen 0.9; р<0.001).Conclusion.The both catheter-based technologies had comparable clinical success. Cryoablation was characterized by improvement in all QoL parameters based on the AFEQT score.