Henrique Coelho Silva

Henrique Coelho Silva

Auto-generated profile, based on publicly available information

Henrique Coelho Silva

Hospital Geral de Fortaleza

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
JHJ.J. Heit
J.J. Heit
HCH. Coelho
H. Coelho
FLF.O. Lima
F.O. Lima
MGM. Granja
M. Granja
AAA. Aghaebrahim
A. Aghaebrahim
FMF. Mont’aLverne
F. Mont’aLverne
BACKGROUND AND PURPOSE: Intracranial hemorrhage (ICH) is an important event that is diagnosed on head NCCT. Increased NCCT utilization in busy hospitals may limit timely identification of ICH. RAPID ICH is an automated hybrid 2D–3D convolutional neural network application designed to detect ICH that may allow for expedited ICH diagnosis. We determined the accuracy of RAPID ICH for ICH detection and ICH volumetric quantification on NCCT. MATERIALS AND METHODS: NCCT scans were evaluated for ICH by RAPID ICH. Consensus detection of ICH by 3 neuroradiology experts was used as the criterion standard for RAPID ICH comparison. ICH volume was also automatically determined by RAPID ICH in patients with intraparenchymal or intraventricular hemorrhage and compared with manually segmented ICH volumes by a single neuroradiology expert. ICH detection accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios by RAPID ICH were determined. RESULTS: We included 308 studies. RAPID ICH correctly identified 151/158 ICH cases and 143/150 ICH-negative cases, which resulted in high sensitivity (0.956, CI: 0.911–0.978), specificity (0.953, CI: 0.907–0.977), positive predictive value (0.956, CI: 0.911-0.978), and negative predictive value (0.953, CI: 0.907–0.977) for ICH detection. The positive likelihood ratio (20.479, CI 9.928–42.245) and negative likelihood ratio (0.046, CI 0.023–0.096) for ICH detection were similarly favorable. RAPID ICH volumetric quantification for intraparenchymal and intraventricular hemorrhages strongly correlated with expert manual segmentation (correlation coefficient r = 0.983); the median absolute error was 3 mL. CONCLUSIONS: RAPID ICH is highly accurate in the detection of ICH and in the volumetric quantification of intraparenchymal and intraventricular hemorrhages.

31 May 2020 in Journal of Stroke
Verified
Journal Article
Open access
PDF file
FAFrancisco José Arruda Mont` Alverne
Francisco José Arruda Mont` Alverne
FLFabricio Oliveira Lima
Fabricio Oliveira Lima
FRFelipe de Araújo Rocha
Felipe de Araújo Rocha
DBDiego de Almeida Bandeira
Diego de Almeida Bandeira
ALAdson Freitas de Lucena
Adson Freitas de Lucena
RNRaul Gomes Nogueira
Raul Gomes Nogueira
The benefit of mechanical thrombectomy (MT) in acute ischemic stroke (AIS) due to large vessel intracranial occlusions is directly related to the technical success of the procedures in achieving fast and complete reperfusion. While a precise definition of refractoriness is lacking in the literature, it may be considered when there is reperfusion failure, long procedural times, or high number of passes with the MT devices. Detailed knowledge about the causes for refractory MT in AIS is limited; however, it is most likely a multifaceted problem including factors related to the vascular anatomy and the underlying nature of the occlusive lesion amongst other factors. We aim to review the impact of several key unfavorable anatomical factors that may be encountered during endovascular AIS treatment and discuss potential bail-out strategies to these challenging situations.

1 March 2021 in Radiology
Verified
Journal Article
Closed access
SDSeena Dehkharghani
Seena Dehkharghani
MLMaarten Lansberg
Maarten Lansberg
CVChitra Venkatsubramanian
Chitra Venkatsubramanian
CCCarlo Cereda
Carlo Cereda
FLFabricio Lima
Fabricio Lima
JHJeremy Heit
Jeremy Heit
Automated software used to detect anterior circulation large vessel occlusion had high performance across subgroups and imaging systems. Background Identification of large vessel occlusion (LVO) is critical to the management of acute ischemic stroke and prerequisite to endovascular therapy in recent trials. Increasing volumes and da...

7 July 2021 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
LCLucas Scotta Cabral
Lucas Scotta Cabral
FMFrancisco Mont’alverne
Francisco Mont’alverne
HSHenrique Coelho Silva
Henrique Coelho Silva
PFPaulo Eloy Passos Filho
Paulo Eloy Passos Filho
PMPedro S C Magalhães
Pedro S C Magalhães
RNRaul G Nogueira
Raul G Nogueira
Background Despite advancements in stroke treatment, refractory clots are relatively common, prompting the exploration of alternative techniques. Bifurcation occlusions pose specific intraprocedural challenges, occasionally dealt with by two stentrievers deployed in Y-configuration. Previous studies have portrayed this strategy as feasible, yet little is known about its safety and efficacy, and how to best select retrievers. Objective To determine whether device selection influences the efficacy and safety of Y-stentrieving. Methods We performed a multicentric, retrospective analysis of patients undergoing Y-stentrieving rescue for bifurcation occlusions. Demographics, devices, procedural metrics, neurological severity, reperfusion, disability, and safety were assessed. Results Y-configuration stents were used as a rescue maneuver after 2.16±1.5 failed attempts with other techniques in 20 patients. Successful reperfusion (modified Thrombolysis in Cerebral Infarction score 2b–3) was achieved in 70% of patients after the first Y-stentrieving attempt. The first stentriever more often had a larger diameter (5.15±0.92 vs 3.67±0.57 mm, p=0.017) and longer length (33.12±5.78 vs 20.67±1.15 mm, p=0.002) in successfully reperfused cases. Also, the diameter of the first device was associated with both any parenchymal (6.0 vs 4.71±0.99 mm, p=0.045) and symptomatic (6.0 vs 4.86±1.02 mm, p<0.001) hemorrhages. Exact logistic regression demonstrated that a longer length first stentriever independently predicted better angiographic outcomes (OR=1.26, p=0.036), and a 6 mm diameter first stentriever independently predicted more intracranial hemorrhages (OR=15.28, p=0.044). No periprocedural mortality was recorded. Conclusion Y-stentrieving is an effective and safe bail-out strategy for refractory bifurcation clots. Longer stents may promote better angiographic outcomes, whereas avoidance of disproportionately large retrievers may mitigate intracranial hemorrhage. Future studies should account for these factors when evaluating alternative stentriever techniques.

16 August 2023 in medRxiv
Verified
Preprint
Open access
PDF file
VYVivek Yedavalli
Vivek Yedavalli
JHJeremy J Heit
Jeremy J Heit
SDSeena Dehkharghani
Seena Dehkharghani
HHHafez Haerian
Hafez Haerian
JMJohn M. Mcmenamy
John M. Mcmenamy
GAGregory W Albers
Gregory W Albers
Background: Noncontrast CT (NCCT) is used to evaluate for intracerebral hemorrhage (ICH) and ischemia in acute ischemic stroke (AIS). Large vessel occlusions (LVOs) are a major cause of AIS, but challenging to detect on NCCT. Aims: The purpose of this study is to evaluate an AI software called RAPID NCCT Stroke (RAPID, iSchemaView, Menlo Park, CA) for ICH and LVO detection compared to expert readers. Methods: In this IRB approved retrospective, multicenter study, stand-alone performance of the software was assessed based on the consensus of 3 neuroradiologists and sensitivity and specificity were determined. The platform’s performance was then compared to interpretation by readers comprised of eight general radiologists (GR) and three neuroradiologists (NR) in detecting ICH and hyperdense vessel sign (HVS) indicating LVO. Receiver operating characteristics (ROC) curve was used to evaluate the performance of each reader. P < 0.05 was considered significant. Results: A total of 244 cases were included. Of the 244, 115 were LVOs and 26 were ICHs. One hundred three cases did not have LVO nor ICH. Stand-alone performance of the software demonstrated sensitivities and specificities of 96.2% and 99.5% for ICH and 63.5% and 95.1% for LVO detection. Compared to all 11 readers and eight GR readers only respectively, the software demonstrated superiority, achieving significantly higher sensitivities (63.5% versus 43.6%, p < 0.0001 and 63.5% versus 40.9%, p =0.001). Conclusion: The RAPID NCCT Stroke platform demonstrates superior performance to radiologists for detecting LVO from a NCCT. Use of this software platform could lead to earlier LVO detection and expedited transfer of these patients to a thrombectomy capable center.