Caleb E. Stewart

Caleb E. Stewart

Auto-generated profile, based on publicly available information

Caleb E. Stewart

Section of Neurosurgery, Dartmouth-Hitchcock Medical Center,Lebanon,USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2020 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
CSCaleb E. Stewart
Caleb E. Stewart
CKChin Fung Kelvin Kan
Chin Fung Kelvin Kan
BSBrody R. Stewart
Brody R. Stewart
HSHenry William Sanicola
Henry William Sanicola
JJJangwook P Jung
Jangwook P Jung
Dadong WangDadong Wang
Dadong Wang
Nerve guidance conduits (NGCs) have emerged from recent advances within tissue engineering as a promising alternative to autografts for peripheral nerve repair. NGCs are tubular structures with engineered biomaterials, which guide axonal regeneration from the injured proximal nerve to the distal stump. NGC design can synergistically combine multiple properties to enhance proliferation of stem and neuronal cells, improve nerve migration, attenuate inflammation and reduce scar tissue formation. The aim of most laboratories fabricating NGCs is the development of an automated process that incorporates patient-specific features and complex tissue blueprints (e.g. neurovascular conduit) that serve as the basis for more complicated muscular and skin grafts. One of the major limitations for tissue engineering is lack of guidance for generating tissue blueprints and the absence of streamlined manufacturing processes. With the rapid expansion of machine intelligence, high dimensional image analysis, and computational scaffold design, optimized tissue templates for 3D bioprinting (3DBP) are feasible. In this review, we examine the translational challenges to peripheral nerve regeneration and where machine intelligence can innovate bottlenecks in neural tissue engineering.

10 December 2025
Verified
Conference Paper
Closed access
FAFarzad Ahmadi
Farzad Ahmadi
CSCaleb E. Stewart
Caleb E. Stewart
This paper introduces an implantable sensor system with telemetric capabilities, designed to detect and communicate malfunctions in cerebrospinal fluid (CSF) shunts. Using Ansys Electronics Desktop, the system was simulated on a commercially available ventriculoperitoneal (VP) shunt for detecting catheter occlusions. The proposed system utilizes a flexible C-shaped capacitive sensor wrapped around the catheter to detect the presence and absence of CSF by monitoring capacitance variations. These changes alter the resonance frequency of the system, which can be measured using a wireless reader coil located outside the body. The results demonstrated the sensor's sensitivity to CSF variations, with measurable shifts in resonance frequencies under different conditions. This approach offers a telemetric solution for real-time monitoring of CSF shunt function.

28 November 2025 in Advanced Materials Technologies
Verified
Journal Article
Closed access
LOLevi Micha Olevsky
Levi Micha Olevsky
JPJonathan C. Pelusi
Jonathan C. Pelusi
CSCaleb E. Stewart
Caleb E. Stewart
PBPeter Mark Bertone
Peter Mark Bertone
AKAmir Khan
Amir Khan
ABAlexander J. Boys
Alexander J. Boys