Wei Lee Woon

Wei Lee Woon

Auto-generated profile, based on publicly available information

Wei Lee Woon

Department of Electrical Engineering and Computer Science, Masdar Institute of Science and Technology, Abu Dhabi, UAE

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
BABedoor K. AlShebli
Bedoor K. AlShebli
TRTalal Rahwan
Talal Rahwan
WWWei Lee Woon
Wei Lee Woon
Inspired by the social and economic benefits of diversity, we analyze over 9 million papers and 6 million scientists to study the relationship between research impact and five classes of diversity: ethnicity, discipline, gender, affiliation, and academic age. Using randomized baseline models, we establish the presence of homophily in ethnicity, gender and affiliation. We then study the effect of diversity on scientific impact, as reflected in citations. Remarkably, of the classes considered, ethnic diversity had the strongest correlation with scientific impact. To further isolate the effects of ethnic diversity, we used randomized baseline models and again found a clear link between diversity and impact. To further support these findings, we use coarsened exact matching to compare the scientific impact of ethnically diverse papers and scientists with closely-matched control groups. Here, we find that ethnic diversity resulted in an impact gain of 10.63% for papers, and 47.67% for scientists.

1 August 2017 in ISPRS Journal of Photogrammetry and Remote Sensing
Verified
Journal Article
Closed access
RARasha Alshehhi
Rasha Alshehhi
Prashanth MarpuPrashanth Marpu
Prashanth Marpu
WWWei Lee Woon
Wei Lee Woon
Mauro Dalla MuraMauro Dalla Mura
Mauro Dalla Mura

3 April 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WNWaleed K. A. Najy
Waleed K. A. Najy
HZH. H. Zeineldin
H. H. Zeineldin
WWWei Lee Woon
Wei Lee Woon
Microgrids can be operated either grid-connected to reduce system losses and for peak shaving or islanded to increase reliability and provide backup power during utility outage. Such dual configuration capability imposes challenges on the design of the protection system. Fault current magnitudes will vary depending on the microgrid operating mode. In this paper, a microgrid protection scheme that relies on optimally sizing fault current limiters and optimally setting directional overcurrent relays is proposed. The protection scheme is optimally designed taking into account both modes of operation (grid-connected and islanded). The problem has been formulated as a constrained nonlinear programming problem and is solved using the genetic algorithm with the static penalty constraint-handling technique. The proposed approach is tested on two medium-voltage networks: a typical radial distribution system and on the IEEE 30-bus looped power distribution system equipped with directly connected conventional synchronous generators.

5 December 2013 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
ECE. Casagrande
E. Casagrande
WWW. L. Woon
W. L. Woon
HZH. H. Zeineldin
H. H. Zeineldin
DSD. Svetinovic
D. Svetinovic
The protection of a microgrid containing inverter- based distributed generators (IBDGs) presents several problems if traditional techniques which rely on the current (fuses and overcurrent relays) are used. A possible solution to these problems is the use of a new type of the relay which takes advantage of the enhanced processing techniques and communication infrastructure, both of which are recently becoming available for power networks application. This paper proposes a new communication-based protection scheme for isolated microgrids where a data mining approach is used to identify the relay settings and parameters. A feature selection technique is implemented to help identify the most relevant electrical features required for the fault detection and to establish the best communication strategy to use between relays. The proposed approach is tested using a MATLAB simulation of a facility scale isolated microgrid embedded with IBDGs. The results show that a differential protection scheme that relies on symmetrical components is the most effective strategy for protecting microgrids with IBDGs.

6 June 2017 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
SPSokratis Papadopoulos
Sokratis Papadopoulos
EAElie Azar
Elie Azar
WWWei-Lee Woon
Wei-Lee Woon
CKConstantine E. Kontokosta
Constantine E. Kontokosta

19 July 2011 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
WNWaleed K. A. Najy
Waleed K. A. Najy
HZH. H. Zeineldin
H. H. Zeineldin
AAAli H. Kasem Alaboudy
Ali H. Kasem Alaboudy
WWWei Lee Woon
Wei Lee Woon
In this paper, a new passive islanding detection method for grid-connected inverter-based distributed-generation (DG) systems is proposed. A statistical signal-processing algorithm known as estimation of signal parameters via rotational invariance techniques is used to extract new features from measurements of the voltage and frequency at the point of common coupling as islanding indicators. The new features are defined based on a damped-sinusoid model for power system voltage and frequency waveforms, and include modal initial amplitudes, oscillation frequencies, damping factors, and initial phases. A set of training cases generated on the IEEE 34-bus system was used to train a naïve-Bayes classifier that discriminates islanding and nonislanding events. Cross-validation was used to evaluate the performance of the proposed islanding detection method. The results show that by using the new features extracted from ESPRIT, the classifier is capable of discriminating islanding and nonislanding events with an accuracy close to 100%.