Daniel James McKeown

Daniel James McKeown

Auto-generated profile, based on publicly available information

Daniel James McKeown

Bond University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2023 in Cerebral Cortex
Verified
Journal Article
Open access
PDF file
DMDaniel J McKeown
Daniel J McKeown
AFAnna J Finley
Anna J Finley
NKNicholas J Kelley
Nicholas J Kelley
JCJames F Cavanagh
James F Cavanagh
HKHannah Keage
Hannah Keage
DADouglas Angus
Douglas Angus
SpecParam (formally known as FOOOF) allows for the refined measurements of electroencephalography periodic and aperiodic activity, and potentially provides a non-invasive measurement of excitation: inhibition balance. However, little is known about the psychometric properties of this technique. This is integral for understanding the usefulness of SpecParam as a tool to determine differences in measurements of cognitive function, and electroencephalography activity. We used intraclass correlation coefficients to examine the test-retest reliability of parameterized activity across three sessions (90 minutes apart and 30 days later) in 49 healthy young adults at rest with eyes open, eyes closed, and during three eyes closed cognitive tasks including subtraction (Math), music recall (Music), and episodic memory (Memory). Intraclass correlation coefficients were good for the aperiodic exponent and offset (intraclass correlation coefficients > 0.70) and parameterized periodic activity (intraclass correlation coefficients > 0.66 for alpha and beta power, central frequency, and bandwidth) across conditions. Across all three sessions, SpecParam performed poorly in eyes open (40% of participants had poor fits over non-central sites) and had poor test-retest reliability for parameterized periodic activity. SpecParam mostly provides reliable metrics of individual differences in parameterized neural activity. More work is needed to understand the suitability of eyes open resting data for parameterization using SpecParam.

8 November 2023 in Psychophysiology
Verified
Journal Article
Open access
DMDaniel J. McKeown
Daniel J. McKeown
MJManon Jones
Manon Jones
CPCamilla Pihl
Camilla Pihl
AFAnna J. Finley
Anna J. Finley
NKNicholas Kelley
Nicholas Kelley
DADouglas Angus
Douglas Angus
Parkinson's disease (PD) has been associated with greater total power in canonical frequency bands (i.e., alpha, beta) of the resting electroencephalogram (EEG). However, PD has also been associated with a reduction in the proportion of total power across all frequency bands. This discrepancy may be explained by aperiodic activity (exponent and offset) present across all frequency bands. Here, we examined differences in the eyes‐open (EO) and eyes‐closed (EC) resting EEG of PD participants (N = 26) on and off medication, and age‐matched healthy controls (CTL; N = 26). We extracted power from canonical frequency bands using traditional methods (total alpha and beta power) and extracted separate parameters for periodic (parameterized alpha and beta power) and aperiodic activity (exponent and offset). Cluster‐based permutation tests over spatial and frequency dimensions indicated that total alpha and beta power, and aperiodic exponent and offset were greater in PD participants, independent of medication status. After removing the exponent and offset, greater alpha power in PD (vs. CTL) was only present in EO recordings and no reliable differences in beta power were observed. Differences between PD and CTL in the resting EEG are likely driven by aperiodic activity, suggestive of greater relative inhibitory neural activity and greater neuronal spiking. Our findings suggest that resting EEG activity in PD is characterized by medication‐invariant differences in aperiodic activity which is independent of the increase in alpha power with EO. This highlights the importance of considering aperiodic activity contributions to the neural correlates of brain disorders.

1 May 2019 in Journal of Neurophysiology
Verified
Journal Article
Closed access
PDF file
DMDaniel J. McKeown
Daniel J. McKeown
MSMichael J. Simmonds
Michael J. Simmonds
JKJustin J. Kavanagh
Justin J. Kavanagh
This study aimed to quantify how acute hypoxia impacts firing characteristics of biceps brachii motor units (MUs) during sustained isometric elbow flexions. MU data were extracted from surface electromyography (EMG) during 25% maximal voluntary contractions (MVC) in 10 healthy subjects (age 22 ± 1 yr). Blood oxygen saturation (SpO2) was then stabilized at 80% by reducing 1% of the fraction of inspired oxygen every 3 min for 35 min. MU data were once again collected 1 h and 2 h following the 35-min desaturation phase. Although MVC remained unaffected during 2 h of 80% SpO2, subject-specific changes in MU firing rate were observed. Four of 10 subjects exhibited a decrease in firing rate 1 h postdesaturation (12 ± 11%) and 2 h postdesaturation (16 ± 12%), whereas 6 of 10 subjects exhibited an increase in firing rate 1 h (9 ± 6%) and 2 h (9 ± 4%) postdesaturation. These bidirectional changes in firing rate were strongly correlated to the desaturation phase and the subjects’ SpO2 sensitivity to oxygen availability, where subjects who had decreased firing rates reached the target SpO2 20 min into the desaturation phase ( R2 = 0.90–0.98) and those who had increased firing rates reached the target SpO2 35 min into the desaturation phase ( R2 = 0.87–0.98). It is unlikely that a single mechanism accounted for these subject-specific changes in firing rate. Instead, differences in intrinsic properties of the neurons, afferent input to the motoneurons, neuromodulators, and sympathetic nerve activity may exist between groups. NEW & NOTEWORTHY The mechanisms of compromised motor control when exposed to hypoxia are largely unknown. The current study examined how severe acute hypoxia affects motor unit firing rate during sustained isometric contractions of the bicep brachii. The response to hypoxia was different across subjects, where motor unit firing rate increased for some individuals and decreased for others. This bidirectional change in firing rate was associated with how fast subjects desaturated during hypoxic exposure.

7 April 2025 in Neurobiology of Aging
Verified
Journal Article
Open access
DMDaniel J. McKeown
Daniel J. McKeown
EREmily Roberts
Emily Roberts
AFAnna J. Finley
Anna J. Finley
NKNicholas J. Kelley
Nicholas J. Kelley
HKHannah A.D. Keage
Hannah A.D. Keage
DADouglas J. Angus
Douglas J. Angus
Age-related cognitive decline associations with human electroencephalography (EEG) have previously focused on periodic activity. However, EEG primarily consists of non-oscillatory aperiodic activity, characterised with an exponent and offset value. In a secondary analysis of a cohort of 111 healthy participants aged 17 - 71 years, we examined the associations of the aperiodic exponent and offset in resting EEG with a battery of cognitive tests consisting of the Colour-Word Interference Test, Wechsler Adult Intelligence Scale IV Digit Span Test, Rey Auditory Learning Test, Delis-Kaplan Executive Function System Trail Making Test, and the Verbal Fluency Test. Using Principal Component Analysis and K-Means Clustering, we identified clusters of electrodes that exhibited similar aperiodic exponent and offset activity during resting-state eyes-closed EEG. Robust linear models were then used to model how aperiodic activity interacted with age and their associations with performance during each cognitive test. Offset by age interactions were identified for the Verbal Fluency Test, where smaller offsets were associated with poorer performance in adults as early as 33 years of age. Greater aperiodic activity is increasingly related to better verbal fluency performance with age in adulthood.

10 February 2023 in Experimental Physiology
Verified
Journal Article
Open access
MMMonica Marzouk
Monica Marzouk
DMDaniel J. McKeown
Daniel J. McKeown
DBDavid N. Borg
David N. Borg
JHJonathon Headrick
Jonathon Headrick
JKJustin J. Kavanagh
Justin J. Kavanagh
The purpose of this study was to determine the relationship between transcranial magnetic stimulation (TMS) measures of performance fatigability and commonly used scales that quantify perceptions of fatigue during exercise. Twenty healthy participants (age 23 ± 3 years, 10 female) performed 10 submaximal isometric elbow flexions at 20% maximal voluntary contraction (MVC) for 2 min, separated by 45 s of rest. Biceps brachii muscle electromyography and elbow flexion torque responses to single‐pulse TMS were obtained at the end of each contraction to assess central factors of performance fatigability. A rating of perceived exertion (RPE) scale, Omnibus Resistance scale, Likert scale, Rating of Fatigue scale and a visual analogue scale (VAS) were used to assess perceptions of fatigue at the end of each contraction. The RPE (root mean square error (RMSE) = 0.144) and Rating of Fatigue (RMSE = 0.145) scales were the best predictors of decline in MVC torque, whereas the Likert (RMSE= 0.266) and RPE (RMSE= 0.268) scales were the best predictors of electromyographic amplitude. Although the Likert (RMSE = 7.6) and Rating of Fatigue (RMSE = 7.6) scales were the best predictors of voluntary muscle activation of any scale, the number of contractions performed during the protocol was a better predictor (RMSE = 7.3). The ability of the scales to predict TMS measures of performance fatigability were in general similar. Interestingly, the number of contractions performed was a better predictor of TMS measures than the scales themselves.

1 July 2022 in Journal of Neurophysiology
Verified
Journal Article
Closed access
PDF file
EBEmily J. Brotherton
Emily J. Brotherton
SSSurendran Sabapathy
Surendran Sabapathy
DMDaniel J. Mckeown
Daniel J. Mckeown
JKJustin J. Kavanagh
Justin J. Kavanagh
People with multiple sclerosis (PwMS) typically experience greater levels of exercise-induced fatigue compared with healthy individuals. Therefore, this study examined performance fatigability in PwMS when executing a prolonged submaximal contraction. Nine PwMS (38 ± 7 yr, 6 females) and nine healthy controls (35 ± 6 yr, 4 females) performed an elbow flexion at 15% maximal voluntary contraction (MVC) for 26 min. MVCs were performed every 2 min during, and following, the contraction to determine if maximal force was impaired by the low-intensity contraction. Single-pulse transcranial magnetic stimulation (TMS) was delivered to the primary motor cortex with a circular coil during each MVC and during the submaximal contraction. Superimposed and resting twitches were calculated from elbow flexion torque, whereas motor-evoked potentials were calculated from biceps brachii electromyography. Ratings of perceived exertion (RPE) were obtained before each MVC. During the fatiguing contraction protocol, the MS group exhibited a reduced MVC torque compared with the healthy control group (P = 0.044), which aligned with group differences in biceps brachii EMG activity (P = 0.022) and superimposed twitch amplitude (P = 0.016). Fatigue-related decrements in MVC torque (P = 0.044) and biceps brachii EMG activity (P = 0.043) demonstrated in the MS group persisted throughout recovery. However, MS did not affect the RPE during the fatigue task. These findings suggest that PwMS may have greater levels of performance fatigability due to decreased voluntary drive from the motor cortex, which is not associated with greater ratings of perceived exertion. NEW & NOTEWORTHY By combining TMS and motor nerve stimulation during a low-intensity exercise task, we were able to uncover the contribution that different levels of the CNS have during fatiguing exercise in PwMS. Our findings are novel and revealed that PwMS experienced decreased voluntary drive from the motor cortex during a low-intensity sustained fatiguing task that was associated with heightened levels of performance fatigability.